For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6.4 — DESIGN STANDARDS

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 6, § 6.4

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/3f7ca80e-953e-443b-9bbb-82e4ce8a512b

6.4 - DESIGN STANDARDS

The following design standards apply only to new construction in the I-MU District. A. Industrial Districts Design Standards Table 6-2: Industrial Districts Design Standards applies to new construction and to any additions to a structure existing as of the effective date of this Code that exceed 30% or more of the existing structure's square footage in the I-MU District. Table 6-2: Industrial Districts Design Standards | | I-MU Façade Design | Building façades that abut a public right-of-way, excluding alleys, must not contain blank wall areas that exceed 30 linear feet, measured parallel to the street. | • Building façades in excess of 100 linear feet that abut a public right-of-way, excluding alleys, must include a repeating pattern with no less than two of the following elements: texture change, material module change, or a wall articulation change of no less than 2 feet in depth or projection, such as a reveal, pilaster, or projecting rib. All elements must repeat at intervals of no more than 50 linear feet. | • All buildings must have a public entrance from the sidewalk along the primary building frontage. Public entrances must be visually distinctive from the remaining portions of the façade along which they are located. | • Building materials and visual elements used on the primary building frontage must continue on all building façades that are visible from a public right-of-way. | • Fenestration Design | The ground floor of the front façade must maintain a minimum transparency of 30%, measured between two and ten feet in height from grade. | • Upper floors of the front façade must maintain a minimum transparency of 15% of the wall area of the story | • Commercial Site Design | Sites must be designed to ensure safe pedestrian access from the public right-of-way, and safe pedestrian circulation within the development. | • Surface parking may not be located between a principal building and the front lot line. Parking must be located to the side or rear of the principal building. | • B. Building Material Restrictions In the I-MU District, the following building materials are prohibited on any façade facing a public right-of-way, excluding alleys, or any façade that abuts a residential district. Such materials may still be used as decorative or detail elements for up to 25% of the façade, or as part of the exterior construction that is not used as a surface finish material. 1. Plain concrete masonry units (CMU); 2. Aluminum, steel or other metal sidings; this restriction does not include metal architectural wall panels; 3. Exposed aggregate concrete wall panels; 4. T-111 composite plywood siding; 5. Plastic; 6. Vinyl.

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.