§ 21-105 — Sound measurement procedures
Code of Ordinances, City of Murfreesboro, Tennessee (Supp. No. 18: codified through Ordinance No. 26-O-38, enacted September 17, 2026) · Murfreesboro City Code § 21-105
Corpus is an independent public-information project, not the official City of Murfreesboro website. Stable reference: corpuslaw.us/code/5a1e5360-821a-4703-9e53-2c2a48ac7766
Section 21-105 - Sound measurement procedures.
(A) Sound Measurement Equipment. (1) All sound level measurements made by the City pursuant to this Article shall be made using a sound level meter in good operating condition and that meets the requirements of a Type 1 or Type 2 instrument, as described in American National Standards Institute (ANSI) S1.4 2014 "Sound Level Meters", as it exists as of the effective date of this Article or as such requirements are hereafter amended. (2) Acoustic calibrators used to calibrate a sound level meter should be those recommended by the manufacturer of the sound level meter. (3) Each sound level meter used in connection with the enforcement and administration of this Article must be recalibrated and the acoustic calibrator must be recalibrated at least once per year by the manufacturer or by a laboratory accredited for such calibrations by either the American Association for Laboratory Accreditation or the National Institute of Standards and Technology. A copy of written documentation of such recalibration shall be kept with the equipment to which it refers. (B) Operating conditions during sound measurement. Insofar as practicable, sound will be measured while the source under investigation is operating at normal, routine conditions and, as necessary, at other conditions including, but not limited to, design, maximum and fluctuating rates. (C) General requirements. All tests shall be conducted in accordance with the following procedures: (1) The Noise Control Officer shall, to the extent practicable, identify and document all sources contributing sound to the point of measurement. Prior to taking any noise measurements, the Noise Control Officer shall explore, as is reasonable under the circumstances, the vicinity of the source in question to identify any other sound sources that could affect measurements, to establish the approximate location and character of the principal sound source, and to select suitable locations from which to measure the sound from the source in question. (2) Except as otherwise provided in this Article, measurements shall be taken at or near the nearest real property boundary of the property receiving the alleged offending sound. (3) The Noise Control Officer shall conduct an external calibration of the sound level meter using an acoustic calibrator immediately before and after a series of measurements at each test site. The Noise Control Officer shall also conduct a calibration check at least once every hour during the measurement period to ensure continuing accuracy of the meter. (4) Unless the sound level meter's manufacturer specifications allow adjustments to be made to compensate for the following factors, no outdoor measurements shall be taken: (a) During periods when the wind speed (including gusts) exceeds 15 miles per hour; (b) Without a windscreen, recommended by the meter's manufacturer, properly attached to the meter; (c) Under any condition that would cause the meter to become wet, such as rain, snow, fog, or condensation; or (d) When the ambient temperature is out of the meter's range of tolerance. (5) No measurement may be taken on private property without the permission of the owner or the owner's representative or, in the absence thereof, without a search warrant or court order. (6) During measurement, the meter and microphone must be taken from a distance of at least three feet above the ground or from any reflective surface, including the wall, floor, or ceiling of any structure or any interior room. (7) When conducting interior sound level measurements, all sound sources within the residence, dwelling unit or other interior space in which the measurement is being taken that can reasonably be discontinued (e.g., television, stereo) shall be discontinued. Exterior doors and windows may be opened or closed, at the discretion of the Noise Control Officer. (8) If the microphone is handheld, it must held at arm's length and be pointed at the alleged offending sound source at the angle recommended by the meter's manufacturer. (9) If extraneous sound sources, such as aircraft flyovers or barking dogs that are unrelated to measurements increase the monitored sound levels, the measurements should be postponed until these extraneous sounds have become of such a level as not to increase the monitored sound levels of interest. (10) The measurement period should be sufficient in length to ensure that the sound levels measured are typical of the source in question. Except when measuring sound levels associated with an impulsive sound, in no event shall the duration of testing be less than one minute. (11) Notwithstanding the foregoing, when the location or distance prescribed in this Article for measurement of sound is impractical or would provide misleading or inaccurate results, measurements may be taken at other locations or distances using appropriate correction factors specified in this Article or the latest version of ANSI S1.4 2014. (D) Equipment settings. When using a sound level meter to enforce the provisions of Code § 21-106, the Noise Control Officer shall utilize the settings specified below for the specific type of sound being evaluated. (1) Non-impulsive sounds. Except as set forth otherwise in this Article, the sound level of a sound that is sustained for more than one second at a time and shall be measured using the A-weighting scale and the fast response settings on the sound level meter, unless otherwise specified in the most recent version of ANSI S1.4-2014. (2) Measurement of impulsive sounds. The sound level of an impulsive sound shall be measured using the C-weighting scale and peak/impulse settings on the sound level meter, unless otherwise specified in the most recent version of ANSI S1.4-2014. (3) Measurement of sounds with significant low-frequency components. The sound level of a sound with significant low-frequency components, e.g., certain sound amplification devices and heavy equipment or machinery, in addition to being measured in accordance with subsection (1), may also be measured using the C-weighting scale and the fast response setting on the sound level meter for purposes of establishing compliance with the applicable sound level limits. (E) Adjustment for background interference. (1) Wherever possible, the background sound level should be measured at the same location on the receiving property used to measure the alleged offending noise source. Background sound levels shall be taken using the same weighting scale as being evaluated and the fast response setting on the sound level meter. (2) If the source of interest can be turned off, the Noise Control Officer shall subtracted the background sound level from the measured sound levels of the source(s) of interest (i.e., ambient sound level) by using Table 1 to determine the sound levels from the source(s) of interest alone. Table 1 Difference between ambient and background levels | Correction factor to be subtracted from ambient level to determine source level 3 | 3 4—5 | 2 6—9 | 1 10 or more | 0 (3) If the intruding noise source cannot reasonably be discontinued or stopped for a period of time sufficient to allow the measurement of the background sound level, the background sound level may be determined by the decibel reading traveling away from the noise source to a point where a steady-state decibel reading is achieved. (F) Reporting requirements. (1) The Noise Control Officer shall complete a report for each measurement session on forms approved by the Chief of Police and Chief Building Official. The report for each measurement session should include such facts as may be necessary to demonstrate that a violation has occurred, including: (a) The date, day of week, and times at which measurements are taken; (b) The times of calibration; (c) The weather conditions, including wind speed and temperature; (d) The identification of all monitoring equipment by manufacturer, model number, and serial number; (e) A description and/or sketch of the measurement site, including measurement locations and relevant distances and other information sufficient for another investigator to repeat the measurement under similar conditions; (f) A description of the sound(s) in question; (g) The measured sound levels, including the minimum, maximum (or peak), and mean sound levels, measured to the nearest decibel, and duration(s) of the sound(s) in question; (h) The ambient sound level with the source(s) in question operating and a description of other sound sources contributing to the ambient sound level, if obvious; and (i) The background sound level without the source(s) in question operating. (2) Information required to support the issuance of a citation shall be considered sufficient if the data captured by the sound level meter provides such information, and/or such information can be provided by the citation and/or the testimony of the Noise Control Officer taking such readings, and/or such other reports generated by the Noise Control Officer.
(Ord. No. 85-15 § 1, 05-16-85; Ord. No. 14-O-50 §§ 1, 2, 11-13-14)
Ask a question about Murfreesboro law
Corpus searches the Murfreesboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.