§ 23-2 — International Plumbing Code—Amended
Code of Ordinances, City of Murfreesboro, Tennessee (Supp. No. 18: codified through Ordinance No. 26-O-38, enacted September 17, 2026) · Murfreesboro City Code § 23-2
Corpus is an independent public-information project, not the official City of Murfreesboro website. Stable reference: corpuslaw.us/code/fa543ee3-cfb2-45f1-8795-a50404f2b5f1
Section 23-2 - International Plumbing Code—Amended.
(A) Section 101.1 is amended by deleting the phrase "[name of jurisdiction]" and substituting in lieu thereof the phrase "the City of Murfreesboro, Tennessee." (B) Section 103.1 on creation of agency is amended by deleting the phrase "[insert name of department]" and substituting in lieu thereof the phrase "Building and Codes Department." (C) Section 105.2 on plumbing work exempt from permits is amended by adding an exemption immediately after exemption 2, to read as follows: "(3) Emergency repairs may be performed at night, on weekends and holidays, and during a natural disaster, without first obtaining a permit. However, a permit must be obtained within the next two working days, unless the type of work performed is exempt from a permit." (D) Section 108.2 on fee schedule is amended by deleting the text of this section in its entirety and in lieu thereof substituting the following: "Permit fees shall be set by the City Council." (E) Section 108.4 on work commencing before permit issuance is amended by adding the following sentence to the end of the section: "The Chief Building Official may waive the doubling of the established fee where the contractor or other person applying for the permit demonstrates good cause for the failure to obtain the required permit before commencing work." (F) Section 108.6 on refunds is amended by deleting the text of this section in its entirety and in lieu thereof substituting the following: "The City Council shall adopt a policy governing the refunding of permit fees." (G) Section 112 on means of appeals is amended by deleting the text of this section in its entirety and in lieu thereof substituting the following: "Except for appeals for variances to the connection backflow and back-siphonage requirements set forth in this code, the Construction Board of Adjustments and Appeals for the City of Murfreesboro shall have the authority to hear and decide appeals of any order, decision, or determination made by the Chief Building Official relative to the application and interpretation of this code, in accordance with the procedures set forth in Section 7-16 of the Murfreesboro City Code. The Murfreesboro Water Resources Board shall be the backflow and back- siphonage control Board and shall hear all appeals for variances to cross connection backflow and back-siphonage requirements." (H) Section 302 on exclusion of materials detrimental to the sewer system is amended by deleting the section in its entirety and substituting in lieu thereof the following: "Detrimental or dangerous materials and industrial wastes shall comply with Section 33-36 through 33-43 of the Murfreesboro City Code." (I) Section 306.3 on backfilling is amended by adding the following sentence to the end of this section: "All pipe shall be placed on a No. 67 bedding and initial fill of No. 67 stone over the top of the pipe a minimum of six inches in depth". (J) Section 416 on food waste disposer units is amended by deleting the section in its entirety and substituting in lieu thereof the following: "Use of garbage disposals by restaurants, institutional indoor commercial kitchens, or food wholesalers or retailers is prohibited in accordance with Section 33-36(A)(2)(E) of the Murfreesboro City Code." (K) Section 605.3.1 on dual check-valve-type backflow preventers is amended by deleting this section in its entirety and substituting in lieu thereof the following: "Dual check-valve-type backflow preventers shall comply with Section 33-19(F)(2) of the Murfreesboro City Code." (L) Section 607.2 on hot or tempered water supply to fixtures is amended by deleting the phrase "50 feet (15,240 mm)" and in lieu thereof substituting the phrase "100 feet (30,480 mm)." (M) Section 608.1 on protection of the potable water supply is amended by adding at the end of the last sentence the following sentence: "Backflow preventer applications shall comply with Section 33-18 and Section 33-19 of the Murfreesboro City Code, whichever is more restrictive." (N) Section 608.7 on cross connection control is amended by deleting the period at the end of the section and adding the following phrase: "pursuant to Sections 33-18 through 33-22 of the Murfreesboro City Code." (O) Section 608.9 on identification of potable and non-potable water is amended by deleting the period at the end of the section and adding the following phrase: "and Section 33-19(1) of the Murfreesboro City Code." (P) Section 608.14 on backflow protection is amended by deleting the period at the end of the section and adding the following phrase: "and Section 33-18 and Section 33-19 of the Murfreesboro City Code." (Q) Section 608.15 on location of backflow prevention devices is amended by deleting the period at the end of the section and adding the following phrase: "and Section 33-19(G) of the Murfreesboro City Code." (R) Section 608.15.1 on outdoor enclosures for backflow prevention devices is amended by deleting the period at the end of the section and adding the following phrase: "and Section 33-19(G) of the Murfreesboro City Code." (S) Section 608.16.1 on protection by air gaps is amended by adding the following sentence to the end of the section: "The minimum air gap allowed is two inches." (T) Section 608.17.4 on connections to automatic fire sprinkler systems is amended by deleting the period at the end of the section and adding the following phrase: "pursuant to Section 33-19(G) of the Murfreesboro City Code." (U) Section 608.17.5 on connections to lawn irrigation systems is amended by deleting the words "an atmospheric type vacuum breaker, a pressure vacuum breaker or" in the first sentence of this section. (V) Section 701.2 on when connection to sewer required is amended by adding the following immediately after the first sentence of the section: "Where available, a public sewer shall be the same as 'accessible sewer' as defined and regulated in Article IX of Chapter 33 of the Murfreesboro City Code." (W) Section 701.5 on damage to drainage system of public sewer is amended by deleting the phrase "Section 1003" and substituting in lieu thereof the phrase "Section 33-36 through Section 33-43 of the Murfreesboro City Code." (X) Section 702.5 on temperature rating is amended by deleting the sentence, "Where the wastewater temperature will be greater than 140° Fahrenheit (60° Celsius), the sanitary drainage piping material shall be rated for the highest temperature of wastewater" and substituting in lieu thereof the following sentence: "Any liquid or vapor having a temperature higher than 150° Fahrenheit or any combination of temperature and volume sufficient to raise the temperature of the wastewater plant influent to 100° Fahrenheit is prohibited." (Y) Section 702.6 on chemical waste systems is amended by deleting the phrase "Section 803.2" and substituting in lieu thereof the phrase: "Section 33-36 through 33-43 of the Murfreesboro City Code." (Z) Section 703 on building sewers is cumulative by adding the following subsection immediately following subsection 703.6: "703.7 Maximum Building Sewer Length. The length of a building sewer on any single parcel shall not exceed the maximum length established in the most recent version of Section 5.1 of the Murfreesboro Water Resources Department Policies, Procedures and General Design Manual approved by the City Council." (AA) Section 712.1 on building subdrains is amended by adding the following sentence to the end of the section: "In addition, where a sump and/or ejector is installed in accordance with this section, the owner shall execute a release and indemnification agreement in accordance with Section 33-35 (H)(1) of the Murfreesboro City Code." (88) Section 714.1 on backwater valve sewage backflow is amended by adding the following sentence to the end of the section before the exception: "In addition, where a backwater valve is installed in accordance with this section, the owner shall execute a release and indemnification agreement in accordance with Section 33-35 (H)(1) of the Murfreesboro City Code." (CC) Section 802.3.1 on air gaps is amended by adding the following sentence to the end of the section: "The minimum air gap permitted is two inches." (DD) Section 803.2 on special waste system design is amended by adding the following sentence to the end of the section: "Special waste shall also comply with Section 33-35 through Section 33-43 of the Murfreesboro City Code." (EE) Section 903.1.1 on roof extensions is amended by deleting the word "[number]" and substituting in lieu thereof "six (6) inches." (FF) Section 1003.2 on approval of interceptors and separators is amended by adding the following sentence to the end of this section: "Section 33-36(E) and (F) of the Murfreesboro City Code shall govern the size, type, and location of each interceptor and separator." (GG) Section 1003.3.2 on food waste disposers is amended by deleting the section in its entirety and substituting in lieu thereof the following: "Use of garbage disposals by restaurants, institutional indoor commercial kitchens, or food wholesalers or retailers is prohibited in accordance with Section 33-36(A)(2)(E) of the Murfreesboro City Code." (HH) Section 1003.3 on grease interceptors is amended by inserting the following immediately after the first sentence of the section: "Grease interceptors and automatic grease removal devices shall be of a type and capacity specifically approved by the Murfreesboro Water Resources Department and shall be located at a site specifically approved by that Department." (II) Chapter 13 on nonpotable water systems is amended by deleting the chapter in its entirety and replacing it with a new "Chapter 13 Use of Re-Purified Water Systems in Commercial Buildings" that reads as follows: "Section 1301 - General 1301.1 Scope. The provisions of Chapter 13 shall govern the use, materials, design, construction, and installation of re-purified water systems in commercial buildings for flushing of water closets/toilets and urinals. 1301.2 Use of re-purified water. Re-purified water systems may be installed and used only in commercial buildings and only to supply water closets/toilets and urinals. 1301.3 Tests. All components of re-purified water systems shall be tested in accordance with Section 312. 1301.4 Inspections. Re-purified water systems shall be inspected by Murfreesboro Water Resources Department in accordance with Section 107 and as may be required by the Water Resources Director. Section 1302 - Permits 1302.1 When Required. Any owner, authorized agent, or contract who desires to install, enlarge, alter, repair, convert, or replace any re-purified water system in a commercial building, or who causes such work to be done, shall first make application to the Chief Building Official and obtain the required permit for the work. 1302.2 Submittal of plans to Murfreesboro Water Resources Department. All applicants seeking a permit relating to the installation, enlargement, alteration, repair, conversion, or replacement of a re-purified water system must submit a complete set of plans for the system to the Director of the Murfreesboro Water Resources Department, along with any other documentation, legal or otherwise, that may be required by the Murfreesboro Water Resource Director. 1302.3 Approval by Murfreesboro Water Resources Department. No permit relating to the installation, enlargement, alteration, repair, conversion, or replacement of a re-purified water system may issue without the written approval of the Director of the Murfreesboro Water Resources Department. Section 1303 - System Requirements 1303.1 Materials. Pipe materials shall conform to Section 605.4. 1303.2 Identification. All re-purified system piping must be purple in color and labeled "NON-POTABLE - DO NOT DRINK" in black lettering. The purple color must be integral to the material of all pipes, pipe fittings, and appurtenances. Painted pipe, fittings, or appurtenances will not be accepted. The labeling must be permanently applied to the pipe, by either integrating into the pipe during the manufacturing process or by use of a permanently attached label. This label shall be no further apart than four feet on center. If the selected material cannot be manufactured with the required integrated purple color, then a permanent adhesive tape with the purple background and the required lettering must be secured to the entire length of the pipe. The required lettering must be placed so that it is readily visible on at least two sides if the pipe were to be exposed. 1303.3 No cross-connections. There shall be absolutely no cross-connection between the re-purified system and the potable water supply system. This includes, but not limited to: air gaps, back-flow preventers or any other crossconnection control device. 1303.4 Coloring. The re-purified water system shall have a permanent, automatic system that will inject a blue colored dye into the re-purified system. This device must be connected to the re-purified system as it enters the building and before any branches of the system. A check-valve and a separate stop valve shall be installed on the re-purified system prior to the connection of dye system, in order to prevent dye from entering the public portion of the re-purified supply system. 1303.5 Signs. Permanently attached signs stating "CAUTION - NON- POTABLE WATER" shall be placed at the shut off valve for each connected fixture and inside the tank of all tank-type water closets. For urinals said signs shall be placed on the wall directly above the urinal and no higher than eighteen inches above the top of the urinal itself. These signs must be constructed of non-corrosive material with the lettering permanently integrated into the sign."
(Ord. of 02-10-67 § 2; Ord. of 03-27-69 § 2; Ord. of 04-23-70 § 2; Ord. of 06-15-72 § 2; Ord. of 08-17-72 § 2; Ord. of 04-18-74 § 2; Ord. No. 75-7 §§ 1, 2, 04-17-75; Ord. No. 76-8 §§ 1, 2, 03-25-76; Ord. No. 79-32 §§ 1, 2, 11-08-79; Ord. No. 80-3 §§ 2, 3, 05-08-80; Ord. No. 84-3 § 1, 01-05-84; Ord. No. 86-53 § 3, 12-18-86; Ord. No. 88-46 §§ 1, 3, 08-18-88; Ord. No. 94-O-23 § 2, 06-09-94; Ord. No. 95-O-68 § 1, 12-14-95; Ord. No. 01-O-26 § 5, 06-07-01; Ord. No. 02-O-07 § 2, 01-24-02; Ord. No. 07-O-05 §§ 2-8, 02-08-07; Ord. No. 13-O-59 § 14, 01-16-14; Ord. No. 18-O-71, § 14, 01-17-19; Ord. No. 26-O-34, § 12, 9-3-26)
Ask a question about Murfreesboro law
Corpus searches the Murfreesboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.
