For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-12 — International Residential Code—Amended

Code of Ordinances, City of Murfreesboro, Tennessee (Supp. No. 18: codified through Ordinance No. 26-O-38, enacted September 17, 2026) · Murfreesboro City Code § 7-12

Corpus is an independent public-information project, not the official City of Murfreesboro website. Stable reference: corpuslaw.us/code/0b5f8909-dcbc-4745-b727-c7ffcca7dc55

Section 7-12 - International Residential Code—Amended.

The International Residential Code is hereby specifically amended, modified, or deleted as follows: (A) Section R101.1 is amended by deleting the phrase "[name of jurisdiction]" and substituting in lieu thereof the phrase "the City of Murfreesboro, Tennessee." (B) R101.2 is amended by deleting the last portion of the first sentence of the Exception beginning with "where provided with a residential fire sprinkler system complying with Section P2904:" (C) R101.2 is amended by adding the following to item #4. "A medical care facility within a dwelling unit where occupants are incapable of self-preservation, as defined by the 2024 International Building Code, must be sprinkled in accordance with P2904". (D) Section R103.1 on a code compliance agency is amended by deleting the phrase "[insert name of department]" and substituting "Building and Codes Department." (E) Section R105.2 on building work exempted from the permit requirement is amended by deleting exemptions 1, 2, and 10 and substituting in lieu of exemptions 1 and 2 the following: "1. Portable one-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 120 square feet (11.15 m2). 2. Roof covering replacement that does not involve the replacement of the roof deck or framing." (F) Section R105.2 on gas work exempted from the permit requirement is amended by adding the following: "4. Replacement of any gas appliance or equipment with the same input BTU provided such appliance or equipment is installed by a person holding a current mechanical or gas contractor's license with the State of Tennessee." (G) Section R105.2 on mechanical work exempted from the permit requirement is amended by adding the following: "9. Replacement of an HVAC unit where unit heating and cooling capacity and fuel source are not changed." (H) Section R106.1 on submittal documents is amended by adding the following sentence to the end of the first paragraph: "Construction documents for any structure containing three (3) or more townhome units shall be submitted for plans review to verify compliance with building code requirements." (I) Section R106.1.4 on information for construction in flood hazard areas is deleted. Any mention of flood hazard areas in this code should refer to Section 34 (Floodplain Zoning) of the Murfreesboro Zoning Ordinance for regulations. (J) Section R108.2 on schedule of permit fees is amended by deleting the text of this section in its entirety and in lieu thereof substituting the following: "The fees for all work on buildings, structures, electrical, gas, mechanical, and plumbing systems or alterations thereto requiring a permit shall be set by the City Council." (K) Section R108.5 on refunds is amended by deleting the text of this section in its entirety and in lieu thereof substituting the following: "The City Council shall adopt a policy governing the refunding of permit fees." (L) Section R108.6 on work commencing before permit issuance is amended by deleting the phrase "subject to a fee established by the applicable governing authority that shall be in addition to the required permit fees" and in lieu thereof substituting the following: "required to pay two times the established fee for the required permit. The Chief Building Official may waive the doubling of the established fee where the contractor or other person applying for the permit demonstrates good cause for the failure to obtain the required permit before commencing work." (M) Section R112 concerning means of appeals is amended by deleting the text of this section in its entirety and in lieu thereof substituting the following: "The Construction Board of Adjustments and Appeals for the City of Murfreesboro shall have the authority to hear and decide appeals of any order, decision, or determination made by the Chief Building Official relative to the application and interpretation of this code, in accordance with the procedures set forth in Section 7-16 of the Murfreesboro City Code." (N) Table R301.2 establishing climatic and graphic design criteria is amended by inserting the following criteria into the table: Ground Snow Load (lbs.) | 10 Wind Design | Speed (mph) | 115 Topographic effects | No Special Wind Region | No Windborne Debris Zone | No Seismic Design Category | B Subject to Damage From: | Weathering | Severe Frost line depth (inches) | 12" Termite | Moderate to heavy Winter Design Temp (Degrees) | 14° F Ice Barrier Underlayment Required | No Flood Hazards | In accordance with adopted zoning ordinance Air Freezing Index | 366 Mean Annual Temp | 59° F Manual J Design Criteria Elevation (feet) | 615 Latitude (Degrees North) | 35 Winter Heating | 14 Summer Cooling | 94 Altitude Correction Factor | Note P Indoor Design Temperature | 70 Design Temperature Cooling | 75 Heating Temperature Difference | Note P Cooling Temperature Difference | Note P Wind Velocity Cooling | Note P Coincident Wet Bulb | 74 Daily Range | M Winter Humidity | Note P Summer Humidity | Note P (O) Table R301.2 is amended by adding the following to the end of the notes for Table R301.2 manual J design criteria: "p. This value shall be determined using Manual J Design Criteria." (P) Section R302.1 on Exterior Walls is amended by deleting this section, including Table R302.1(1) and Table R302.1(2), in its entirety and in lieu thereof substituting the following: "Section 302.1 Exterior Walls. Exterior walls and their projections, including fireplaces, decks, and roof overhangs shall not be within 5 feet (1524 mm) of a side lot line, except that a soffit or overhang may extend 12 inches (305 mm) into the 5-foot setback if the overhang has a minimum fire resistance rating of 1 hour on the underside or fire blocking is installed between rafters. The exterior walls of single-family dwelling, townhomes, duplexes and zero-lot-line structures shall be at least 10 feet (3,048 mm) from other structures, other than accessory structures, when located on the same lot. HVAC units for all structures must be a minimum of 3 feet (914 mm) from side lot lines, and at least 12" inches (305mm) from the structure they serve or as required by the manufacturer, whichever is greatest." (Q) Section R302.5.1 on opening protection is amended by deleting "and equipped with a self-closing or automatic-closing device" in the last sentence. (R) Section R306 on flood resistant construction is deleted in its entirety. (S) Section R309 on automatic fire sprinkler systems is deleted in its entirety. (T) Section R310.6 on power source is amended to create Exception 3 that shall read: "3. Interconnection and hardwiring of smoke alarms in existing areas shall not be required where the alterations or repairs do not result in the removal of interior walls or ceiling finishes exposing the structure." (U) Section R317.3 on flood hazard areas is deleted. (V) Section R318 is amended by creating a new Section R318.1.1 and inserting the following text immediately after Section R318.1: "R318.1.1 Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces." (W) Section R322 on accessibility is deleted in its entirety. (X) Chapter 11 dealing with energy efficiency is amended by deleting the chapter's text in its entirety and in lieu thereof substituting the following: "Buildings and structures regulated by this code shall comply with the 2024 International Energy Conservation Code, as amended by the Murfreesboro City Code." (Y) Section G2417.1.1 (406.1.1), on inspections is amended by adding the following at the end of the section: "If gas equipment or appliance change outs are made with like equipment or appliances having the same input BTU rating by a gas contractor licensed with the State of Tennessee, no permit or inspection is required." (Z) Section P2502.1 on existing building sewers and drains is amended by deleting the period at the end of the last sentence and adding the following: "and pursuant to Section 33-35 (E) of the Murfreesboro City Code." (AA) Section P2503.8 on inspection and testing of backflow prevention devices is amended by deleting the period at the end of the last sentence and adding the following: "and Sections 33-18 through 33-22 of the Murfreesboro City Code and the Murfreesboro Cross Connection Control Program Procedures Manual." (BB) Section P2602.1 is amended by inserting between the first and second sentences of paragraph 2 of this section the following: "Connection to the public sewer system shall be pursuant to Section 33-33 through 33-35 of the Murfreesboro City Code." (CC) Section P2602.1 is amended by adding the following at the end of the first paragraph: "Private sewage disposal systems shall be allowed pursuant to Section 33-34 of the Murfreesboro City Code and are regulated by the Tennessee Department of Environment and Conservation." (DD) Section P2603.5.1 on sewer depth is amended by deleting "[NUMBER]" in both places and replacing it with "12." (EE) Section P2604.1 on trenching and bedding is amended by deleting it in its entirety and substituting in lieu thereof the following: "All excavation required for the installation of a building sewer shall be open trench work unless otherwise approved in writing by the director of the Water Resources Department. Pipe laying, embedment, and backfill shall be performed in accordance with ASTM C12, latest revision, for clay pipe, and ASTM D2321, latest revision, for all PVC pipe. All pipe shall be placed on a minimum six- inch bedding of number 67 stone below the pipe and an initial backfill of number 67 stone for a minimum depth of six inches over the top of the pipe. Minimum trench width shall be six inches on each side of the pipe." (FF) Section P2604.3 on backfilling is amended by adding the following to the end of this section: "All pipe shall be placed on a minimum six-inch bedding of number 67 stone below the pipe and a final backfill of number 67 stone, which will form a six-inch envelope around the entire pipe." (GG) Section P2605.1 is amended by adding the following to the end of item 2: "The bedding shall be number 67 stone of a minimum six inches in depth." (HH) Section P2902.1 is amended by adding the following to the end of the section the following: "If any requirement in this section conflicts with the City Code, the City Code shall control." (II) Section P2902.3.7 on dual check-valve-type backflow preventers is amended by deleting the period and by adding at the end thereof the following: "provided, however, if any requirement in this section conflicts with the City Code, the City Code shall control." (JJ) Section P2902.5.3 on lawn irrigation systems is amended by deleting from the first sentence the words "an atmospheric-type vacuum breaker, a pressure type vacuum breaker or" and by adding the following at the end of this section: "Connections to lawn irrigation system shall meet the minimum requirements set forth in Murfreesboro City Code 33-19 and the Murfreesboro Cross Connection Program Procedures Manual." (KK) Section 2902.5.4 on connections to automatic sprinkler systems is amended by adding the following to the end of the section: "Connections to automatic sprinkler systems shall be required to meet the minimum requirements set forth in Murfreesboro City Code 33-19(F)(3) and the Murfreesboro Cross Connection Control Program Procedures Manual." (LL) Section P2903.4 on thermal expansion control is amended by deleting the phrase "where required in accordance with Sections P.2903.4.1 and P2903.4.2" and by adding the following sentence at the end of the section: "A thermal expansion tank with a minimum 1-gallon capacity must be installed as close as possible to the first water heater." (MM) Section 2903.8 on size of water service mains, branch mains and risers is amended by deleting "¾ inch" in the first sentence and substituting in lieu thereof "1 inch" and by deleting the period at the end of the sentence and substituting in lieu thereof the following: "and shall extend from the water meter to the first water heater." (NN) Section P3002.2 on building sewers is amended by adding the following to the end of the section: "Building sewers and connections to the public sewer system must comply with Section 33-35 of the Murfreesboro City Code. In addition, the length of a building sewer on any single partial shall not exceed the maximum length established in the most recent version of Section 5.2 of the Murfreesboro Water Resources Department Policies, Procedures and General Design Manual, approved by the City Council." (OO) Section P3005.1 on drainage fittings and connections is amended by adding to the beginning of this section the following: "The building sewer shall be laid at a uniform grade and in straight alignment pursuant to Section 33-35 of the Murfreesboro City Code. Only one offset in the vertical direction and one offset in the horizontal direction shall be allowed. Offsets shall be made with the proper fittings. A horizontal offset to align with the connection to the public sewer system shall be made immediately after the building clean out. The horizontal offset shall not be made closer than 10 feet from the connection to the public sewer. The last 5 feet shall be on grade and in alignment with the connection to the public sewer. No fittings making a change in the horizontal or vertical direction in the last 5 feet of the building sewer will be allowed. The vertical and horizontal alignment of the building sewer must be such to allow a proper connection to the public cleanout. The terminating end of the building sewer must be laid no closer than 30 to 36 inches from the tap." (PP) Section P3005.4 on drain pipe sizing is amended by adding the following to the end of item 5: "The building sewer shall be installed pursuant to Section 33-35 of the Murfreesboro City Code, which requires a minimum 4-inch building sewer from the building drain to the point of connection with the public sewer. The minimum slope shall be 1/8 inch per foot." (QQ) Section P3007.1 on building subdrains is amended by inserting the following sentence between the existing first and second sentences: "In addition, where a sump and/or ejector is installed in accordance with this section, the owner shall execute a release and indemnification agreement in accordance with Section 33-35 (H)(1) of the Murfreesboro City Code." (RR) Section P3008.1 on where backwater valves are required is amended by adding the following sentence to the end of the section: "In dwelling units in which a backwater valve is installed in accordance with this section, the owner shall execute a release and indemnification agreement in accordance with Section 33-35 (H)(1) of the Murfreesboro City Code." (SS) Section P3009 on graywater soil absorption systems is deleted in its entirety.

(Ord. No. 94-O-22 § 2, 06-09-94, Ord. No. 95-O-69 § 1, 12-14-95; Ord. No. 97-O-10 § 2, 03-30-97; Ord. No. 01-O-38 § 6, 08-09-01; Ord. No. 01-O-78 § 12, 01-10-02; Ord. No. 07-O-45 § 2, 12-13-07; Ord. No. 08-O-08 § 1, 05-15-08; Ord. No. 10-O-41 § 1, 01-13-11; Ord. No. 11-O-10 § 1, 06-23-11; Ord. No. 13-O-59 § 5, 01-16-14; Ord. No. 14-O-17 § 1, 05-01-14; Ord. No. 18-O-48, § 1, 8-23-18; Ord. No. 18-O-71, § 4, 01-17-19; Ord. No. 26-O-34, § 4, 9-3-26)

Ask a question about Murfreesboro law

Corpus searches the Murfreesboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.