For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-554 — Substandard structures

Code of Ordinances of the City of Abilene, Texas (Supp. No. 15: codified through Ordinance No. 85-2026, enacted September 24, 2026) · Abilene Code of Ordinances § 8-554

Corpus is an independent public-information project, not the official City of Abilene website. Stable reference: corpuslaw.us/code/2bd866a5-9b1a-4c29-8f50-6e4be01aa5f0

Sec. 8-554. - Substandard structures.

Any building or portion thereof, including any dwelling unit, guest room, or suite of rooms on the premises on which the same is located, in which there exists any of the following conditions, may be deemed to be substandard and condemned if the condition(s) exists to an extent that it endangers the health safety or welfare of the public or the occupants thereof: (1) Inadequate sanitation. Buildings or portions thereof shall be deemed substandard when they are unsanitary. Inadequate sanitation shall include, but not be limited to the following: a. Lack of, or improper water closet, lavatory, bathtub or shower in a dwelling unit or lodging house. b. Lack of, or improper water closets, lavatories and bathtubs or showers per number of hotel guests in a hotel. c. Lack of, or improper kitchen sink in a dwelling unit. d. Lack of hot or cold running water to plumbing fixtures in a dwelling unit, lodging house or hotel. e. Lack of adequate heating facilities. f. Lack of, or improper operation of, required ventilating equipment. g. Lack of minimum amounts of natural light or ventilation required by this Code. h. Room and space dimensions less than required by this Code, including chapter 8, Construction Regulations. i. Lack of required electrical lighting. j. Dampness of habitable rooms. k. Infestations of vermin as determined by the public health authority or designee, or environmental enforcement officer. l. General dilapidation or improper maintenance. m. Lack of connection to required sewage disposal system. n. Sewage flowing across the ground, into the right-of-way, or open sewage. o. Lack of adequate garbage and rubbish storage and removal facilities as determined by the public health authority or designee, or environmental enforcement officer. p. Absence of electric, gas, or water utility for forty-eight (48) hours or more. (2) Structural hazards. Buildings or portions thereof shall be deemed substandard when they are or contain structural hazards. Structural hazards shall include, but not be limited to the following: a. Deteriorated or inadequate foundations. b. Defective or deteriorated flooring or floor supports. c. Flooring or floor supports of insufficient size or construction to carry imposed loads with safety. d. Members of walls, partitions or other vertical supports that split, lean, list or buckle. e. Members of walls, partitions or other vertical supports that are loose, crumbling, rotten or warped or that contain parts that may fall. f. Members of walls, partitions or other vertical supports that are of insufficient size to carry imposed loads with safety. g. Members of ceilings, roofs, ceiling and roof supports or other horizontal members which sag, split or buckle. h. Members of ceilings, roofs, ceiling and roof supports or other horizontal members that are loose, crumbling, rotten or warped or that contain parts that may fall. i. Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that are of insufficient size to carry imposed loads with safety. j. Fireplaces or chimneys which list, bulge or settle. k. Fireplaces or chimneys that are loose, crumbling, rotten or warped or that contain parts that may fall. l. Fireplaces or chimneys which are of insufficient size or strength to carry imposed loads with safety. m. Antennas, towers, flagpoles, wind turbines, solar panels or similar components attached to a structure, which are warped, listing, corroded or otherwise deteriorated. (3) Nuisance. Buildings or portions thereof in which there exists any nuisance as defined in this Code, including chapter 19, Nuisances and Illegal Dumping. (4) Hazardous electrical wiring. Electrical wiring which was installed in violation of code requirements in effect at the time of installation, or electrical wiring not installed in accordance with generally accepted construction practices in areas where no codes were in effect, or which has not been maintained in good condition or which is not being used in a safe manner shall be considered substandard. (5) Hazardous plumbing. Plumbing which was installed in violation of code requirements in effect at the time of installation, or plumbing not installed in accordance with generally accepted construction practices in areas where no codes were in effect, or which has not been maintained in good condition or which is not free of cross-connections or siphonage between fixtures shall be considered substandard. (6) Hazardous mechanical equipment. Mechanical equipment which was installed in violation of code requirements in effect at the time of installation, or mechanical equipment not installed in accordance with generally accepted construction practices in areas where no codes were in effect, or which has not been maintained in good and safe condition shall be considered substandard. (7) Faulty weather protection. Buildings or portions thereof shall be considered substandard when they have faulty weather protection which shall include but not be limited to the following: a. Deteriorated, crumbling or loose plaster. b. Deteriorated or ineffective waterproofing of exterior walls, roof, foundations or floors, including broken windows or doors. c. Defective or lack of weather protection for exterior wall coverings, including the absence of paint where paint is needed to prevent weathering, or weathering due to lack of paint or other approved protective covering. d. Broken, rotted, split, buckled, or missing exterior wall coverings or roof coverings. (8) Fire hazard. Any building or portion thereof, device, apparatus, equipment, combustible waste or vegetation which, in the opinion of the Fire Marshal, is in such a condition as to cause a fire or explosion or provide a ready fuel to augment the spread and intensity of fire or explosion arising from any cause shall be considered a substandard building. (9) Faulty materials of construction. The use of materials of construction, except those which are specifically allowed or approved by this Code and which have been adequately maintained in good and safe condition, shall cause a building to be substandard. (10) Inadequate exits. Buildings or portions thereof whose exit facilities were installed in violation of code requirements in effect at the time of their construction, or whose exit facilities have not been increased in number or width in relation to any increase in occupant load due to alterations, additions or change in use or occupancy subsequent to the time of construction, or whose required exit facilities have been rendered inoperable or unsafe for any reason shall be considered substandard. Notwithstanding compliance with code requirements in effect at the time of their construction, buildings and portions thereof shall be considered substandard when the Building Official finds that an unsafe condition exists through an improper location of exits, a lack of an adequate number or width of exits, or when other conditions exist which are dangerous to human life. (11) Inadequate fire-protection or firefighting equipment. Buildings or portions thereof shall be considered substandard when they are not provided with the fire-resistive construction or the fire-extinguishing systems or equipment required by this Code, except those buildings or portions thereof which conformed with all applicable laws at the time of their construction and whose fire-resistive integrity and fire-extinguishing systems or equipment have been adequately maintained and improved in relation to any increase in occupant load, alteration, or addition, or any change in occupancy. (12) Improper occupancy. All buildings or portions thereof occupied for living, sleeping, cooking or dining purposes which are not designated or intended to be used for such occupancies shall be considered substandard. (13) Improper demolition. Whenever any portion of a building or structure remains on a site after the partial demolition or destruction of the building or structure.

(Ord. No. 54-2013, pt. 1 (Exh. A), 10-24-13)

Ask a question about Abilene law

Corpus searches the Abilene sections it holds and shows the ones that match, with their citations. Free, no sign-in.