Sec. 5.01.7. - Provisions for flood hazard reduction.
1. General standards. All new construction and substantial improvement of structures and other improvements located in areas of special flood hazards, must comply with the following a. Improvements will be designed (or modified) and adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; b. Improvements will be constructed by methods and practices that minimize flood damage; c. Improvements will be constructed with materials resistant to flood damage; d. Improvements will be constructed with electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities designed and/or located to prevent water from entering or accumulating within the components during conditions of flooding; e. All new and replacement water supply systems will be designed to minimize or eliminate infiltration of floodwaters into the system; f. New and replacement wastewater collection systems will be designed to minimize or eliminate infiltration of floodwaters into the system and discharge from the systems into floodwaters; and g. On-site waste disposal systems shall be located to avoid impairment or contamination during flooding. 2. Specific standards. In all areas of special flood hazards where base flood elevation data has been provided, the following is required: a. Residential construction (at grade). New construction and substantial improvement of any residential structure shall have the lowest adjacent grade or lowest floor (including the basement), which ever value is lower to 24 inches above the base flood elevation. A registered professional engineer, architect or surveyor shall certify to the base slab. b. Residential construction (elevated). New construction and substantial improvement of any elevated building shall have the lowest horizontal structural member to 24 inches above the base flood elevation. A registered professional engineer, architect or surveyor shall certify to the lowest horizontal structural member. c. Nonresidential construction. New construction and substantial improvements of any commercial, industrial or other nonresidential structure shall either have the lowest adjacent grade or lowest floor (including basement), which ever value is lower elevated to 18 inches above the base flood elevation together with attendant utility and sanitary facilities and be designed so that below the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are flood proofed shall be maintained by the floodplain administrator. d. Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: i. A minimum of two separate openings on different walls having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; ii. The bottom of all openings shall be no higher than one foot above grade; iii. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. e. Manufactured homes. i. Require that all manufactured homes to be placed within zone A on a community's FHBM or FIRM shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. ii. Require that manufactured homes that are placed or substantially improved within zones A1-30, AH, and AE on the community's FIRM on sites (a) outside of a manufactured home park or subdivision, (b) in a new manufactured home park or subdivision, (c) in an expansion to an existing manufactured home park or subdivision, or (d) in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood, be elevated on a permanent foundation such that the lowest horizontal structural member of the manufactured home is elevated to 24 inches above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. iii. Require that manufactured homes be placed or substantially improved on sites in an existing manufactured home park or subdivision with[in] zones A1-30, AH and AE on the community's FIRM that are not subject to the provisions of paragraph (4) of this section be elevated so that either: (a) The lowest horizontal structural member of the manufactured home is elevated 24 inches above the base flood elevation, or (b) The manufactured home lowest horizontal structural member is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above adjacent grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. e. Recreational vehicles. Require that recreational vehicles placed on sites within zones A1-30, AH, and AE on the community's FIRM either: i. Be on the site for fewer than 180 consecutive days, or ii. Be fully licensed and ready for highway use; or iii. Meet the permit requirements of section 5.01.6.1 and the elevation and anchoring requirements for manufactured homes in subparagraph (d) of this section 5.01.7. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. 3. Standards for subdivision proposals. The following provisions apply: a. All subdivision proposals including the placement of manufactured home parks and subdivisions shall be consistent with sections 5.01.1 and 5.01.2 of this article. b. All proposals for the development of the subdivisions including the placement of manufactured home parks and subdivisions shall meet floodplain development permit requirements of sections 5.01.4, and 5.01.5, and the provisions of section 5.01.7 of this article. c. Base flood elevation data shall be generated for subdivision proposals and other proposed development including the placement of manufactured home parks and subdivisions which is greater than 50 lots or five acres, whichever is lesser, if not otherwise provided pursuant to section 5.01.4 or 5.01.5 of this article. d. All subdivision proposals including the placement of manufactured home parks and subdivisions shall have adequate drainage provided to reduce exposure to flood hazards. e. All subdivision proposals including the placement of manufactured home parks and subdivisions shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize or eliminate flood damage. 4. Floodways. The following provisions apply to floodways: a. Encroachments are prohibited, including fill, new construction, substantial improvements and other development within the adopted regulatory floodway unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in flood levels within the city during the occurrence of the base flood discharge and applicant has applied to the Federal Flood Insurance Administrator for conditional approval of such action prior to permitting the encroachments and shall submit all documents required in 44 CFR 65.12. b. Any new construction or substantial improvements will comply with the flood hazard reduction provisions of this article. 5. Penalties for non-compliance. No structure or land shall hereafter be construed, located, extended, converted, or altered without full compliance with the terms of this article and other applicable regulations. Violation of the provisions of this article by failure to comply with any of its requirements (including violations of conditions and safeguards established in connection with conditions) shall constitute a misdemeanor. Any person who violates this article or fails to comply with any of its requirements shall upon conviction be punished by a fine not to exceed $2,000.00 for each violation, and in addition shall pay all costs and expenses involved in the case. Nothing herein contained shall prevent the city from taking such other lawful action as is necessary to prevent or remedy any violation.
(Ord. No. 3484-6-17, § 1(Exh. A), 6-27-2017)
Ask a question about Allen law
Corpus searches the Allen sections it holds and shows the ones that match, with their citations. Free, no sign-in.