§ 16-2-106 — Safety precautions and equipment
Code of Ordinances, City of Amarillo, Texas (Supp. No. 81: codified through Ordinance No. 8226, enacted December 9, 2025) · Amarillo City Code § 16-2-106
Corpus is an independent public-information project, not the official City of Amarillo website. Stable reference: corpuslaw.us/code/097ad5ff-c03d-4bcf-937d-bd3d26ff9d45
Sec. 16-2-106. - Safety precautions and equipment.
The following safety precautions and equipment shall be installed at each helistop: (1) Rooftop helistops. a. On all touchdown or landing areas, whether elevated or flush with the roof, provision shall be made for collecting fuel which may be spilled in event of any emergency. Separator or clarifier tanks for collecting spilled fuel shall be installed under approval and supervision of the Fire Department. b. The rooftop shall have at least two (2) conforming exits and they shall be located in such a manner as to permit safe exit from the roof area in the event one (1) of the exits is blocked. c. A wind-indicating device shall be installed. A flag, banner or similar device is acceptable. d. Two (2) or more wet standpipes shall be provided and equipped with one-and-one-half-inch rubber-lined fire hose not over one hundred (100) feet in length. Hose shall be equipped with combination fog nozzles. Sufficient pressure shall be available to afford a good fog pattern. Hose cabinets or racks shall be located near the separate exits. Standpipe outlets shall be so located that all portions of the roof area shall be within one hundred twenty (120) feet of the outlet. e. Two (2) fire extinguishers of at least sixteen (16) BC rating shall be provided, and be located remotely from each other. f. No light standards, roof vents, guy lines, TV antennae or other similar rooftop obstructions which may be difficult to see from the air shall be permitted within the required glide slope on three (3) sides, or within a two hundred seventy-degree arc. g. Such lights as are installed shall illuminate and be directed onto the touchdown pad only, and in such a manner that the light rays cannot interfere with the helicopter pilot's vision. h. No persons shall be permitted in the general landing area in any location where any portion of their bodies will be higher than the touchdown area surface while landing or takeoff operations are under way. i. Approved means of communication such as telephone, radio, fire alarm box, or signaling device shall be provided adjacent to the landing area. j. If the roof has no parapet wall, a three-and-one-half-foot-high fence shall be provided around the perimeter of the roof to ensure the safety of all persons. The fence shall be designed to effectively prevent the falling of the helicopter from the roof of the Building. (2) Ground-level helistops. a. All lights installed shall illuminate and be directed onto the touchdown pad only, and in such a manner that the light rays cannot interfere with the pilot's vision. b. A wind-indicating device shall be installed. A flag, banner or similar device is acceptable. c. Unauthorized persons shall not be permitted in the general landing area during flight operations. d. Two (2) fire extinguishers of at least sixteen (16) BC rating shall be provided and be located remotely from each other. e. Where Buildings or Structures in proximity to the landing area present a fire exposure hazard, there shall be provided at least two (2) one-and-one-half-inch wet standpipe outlets equipped with one-and-one-half-inch fire hose, not over one hundred (100) feet in length, and a combination fog nozzle. f. Approved means of communication such as telephone, radio, fire alarm box or signaling device shall be provided adjacent to the landing area.
(Code 1960, § 3A-78)
Ask a question about Amarillo law
Corpus searches the Amarillo sections it holds and shows the ones that match, with their citations. Free, no sign-in.