§ 4-3-41 — Adoption of energy conservation code with amendments
Code of Ordinances, City of Amarillo, Texas (Supp. No. 81: codified through Ordinance No. 8226, enacted December 9, 2025) · Amarillo City Code § 4-3-41
Corpus is an independent public-information project, not the official City of Amarillo website. Stable reference: corpuslaw.us/code/f030dbca-eb26-42a6-b65c-379835211fd6
Sec. 4-3-41. - Adoption of energy conservation code with amendments.
Code adopted. There is hereby adopted the International Energy Conservation Code, 2015 edition, published by the International Code Council with the following amendments, copies of which shall be maintained by the Building official: C101.1 Title. Insert "City of Amarillo" C104.1.1 Contractor Registration. The Building Official shall receive applications from and register contractors according to the rules adopted by the City in Chapter 4-1 of the Amarillo Municipal Code. C107.2 Schedule of permit fees. A fee for each permit shall be paid as required, in accordance with the schedule as provided in Chapter 4-1 of the Municipal Code of Ordinances. C107.3 Work commencing before permit issuance. Any person who commences any work before obtaining the necessary permits shall be subject to fees as provided in Chapter 4-1 of the Municipal Code of Ordinances. C107.5 Refunds. Fee refunds shall be made in accordance with Chapter 4-1 of the Municipal Code. C108.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable to a fine in accordance with section 1- 1-5 of this Municipal Code of Ordinances. [Strike] from ordinance only, it is to remain in the adopted code (2015 IECC), unamended. R402.1 General (Prescriptive). The building thermal envelope shall meet the requirements of 402.1.1 through 402.1.4 as amended until December 31, 2017. Effective January 1, 2018 Table R402.1.1 and Table R402.1.3 will be in effect as printed in 2015 IECC. TABLE N1102.1.2 (R402.1.2) INSulATION AND FENESTRATION REQUIREMENTS BY COMPONENTa Climate Zone | Fenestration U-Factor | Skylightb U-Factor | Glazed Fenestration SHGCb, e | Ceiling R-Value | Wood Frame Wall R-Value | Mass Wall R-Value | Floor R-Value | Basement Wall R-Value | Slab R-Value & Depth | Crawl SpacecWALL R-Value 1 | NR | 0.75 | 0.25 | 30 | 13 | 3/4 | 13 | 0 | 0 | 0 2 | 0.40 | 0.65 | 0.25 | 38 | 13 | 4/6 | 13 | 0 | 0 | 0 3 | 0.35 | 0.55 | 0.25 | 38 | 20 or 13 + 5h | 8/13 | 19 | 5/13 f | 0 | 5/13 4 except Marine | 0.35 | 0.55 | 0.40 | 40 | 15 or 13 +1h | 8/13 | 19 | 10/13 | 5, 12 in. | 10/13 5 and Marine 4 | 0.32 | 0.55 | NR | 49 | 20 or 13 + 5h | 13/17 | 30g | 15/19 | 10, 2 ft | 15/19 6 | 0.32 | 0.55 | NR | 49 | 20 + 5 or 13 40 10h | 15/20 | 30g | 15/19 | 10, 4 ft | 15/19 7 and 8 | 0.32 | 0.55 | NR | 49 | 20 + 5 or 13 + 10h | 19/21 | 38g | 15/19 | 10, 4 ft | 15/19 Footnotes shall remain unchanged. TABLE N1102.1.4 (R402.1.4) EQUIVALENT U-FACTORSa Climate Zone | Fenestration U-Factor | Skylight U-Factor | Ceiling U-Factor | Frame Wall U-Factor | Mass Wall U-Factorb | Floor U-Factor | Basement Wall U-Factor | Crawl Space Wall U-Factor 1 | 0.50 | 0.75 | 0.035 | 0.084 | 0.197 | 0.064 | 0.360 | 0.477 2 | 0.40 | 0.65 | 0.030 | 0.084 | 0.165 | 0.064 | 0.360 | 0.477 3 | 0.35 | 0.55 | 0.030 | 0.060 | 0.098 | 0.047 | 0.091c | 0.136 4 except Marine | 0.35 | 0.55 | 0.026 0.028 | 0.060 0.070 | 0.098 | 0.047 | 0.059 | 0.065 5 and Marine 4 | 0.32 | 0.55 | 0.026 | 0.060 | 0.082 | 0.033 | 0.059 | 0.055 6 | 0.32 | 0.55 | 0.026 | 0.045 | 0.060 | 0.033 | 0.050 | 0.055 7 and 8 | 0.32 | 0.55 | 0.026 | 0.045 | 0.057 | 0.028 | 0.050 | 0.055 Footnotes shall remain unchanged. R403.3.2 Sealing (Mandatory). Ducts, air handlers, and filter boxes shall be sealed. Joints and seams shall comply with either the International Mechanical Code or International Residential Code, as applicable. Exceptions: 1. Air-impermeable spray foam products shall be permitted to be applied without additional joint seals. 2. Where a duct connection is made that is partially inaccessible, three screws or rivets shall be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. 3. Continuously welded and locking-type longitudinal joints and seams in ducts operating at static pressures less than 2 inches of water column (500 Pa) pressure classification shall not require additional closure systems. Duct tightness shall be verified by either of the following: 1. Postconstruction test: Total leakage shall be less than or equal to 4 cfm (113.3 L/min) per 100 square feet (9.29 m 2 ) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test: Total leakage shall be less than or equal to 4 cfm (113.3 L/min) per 100 ft2 (9.29 m 2 ) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm (85 L/min) per 100 square feet (9.29 m 2 ) of conditioned floor area. Exception: The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Duct testing to be done by a company/person who is certified by a recognized accreditation organization and their equipment be recertified on an annual basis. Contractors who choose not to attain the required certification or use the proper testing tools will be required to engage the services of a certified tester.
(Ord. No. 6577, § 1, 12-27-2001; Ord. No. 6881, §§ 1, 2, 12-20-2005; Ord. No. 7102, § 1, 5-20-2008; Ord. No. 7352, § 1, 9-4-2012; Ord. No. 7510, §§ 1, 2, 3-3-15; Ord. No. 8087, § 1, 10-10-2023)
Ask a question about Amarillo law
Corpus searches the Amarillo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
