For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4-5-31 — Irrigation plan design: minimum standards

Code of Ordinances, City of Amarillo, Texas (Supp. No. 81: codified through Ordinance No. 8226, enacted December 9, 2025) · Amarillo City Code § 4-5-31

Corpus is an independent public-information project, not the official City of Amarillo website. Stable reference: corpuslaw.us/code/da291924-b28a-4e21-a3cb-6d6b383c09ea

Sec. 4-5-31. - Irrigation plan design: minimum standards.

(a) An irrigator shall prepare an irrigation plan for each site where a new irrigation system will be installed. A paper or electronic copy of the irrigation plan must be on the job site at all times during the installation of the irrigation system. A drawing showing the actual installation of the system is due to each irrigation system owner after all new irrigation system installations. During the installation of the irrigation system, variances from the original plan may be authorized by the licensed irrigator if the variance from the plan does not: (1) Diminish the operational integrity of the irrigation system; (2) Violate any requirements of this ordinance; and (3) Go unnoted in red on the irrigation plan. (b) The irrigation plan must include complete coverage of the area to be irrigated. If a system does not provide complete coverage of the area to be irrigated, it must be noted on the irrigation plan. (c) All irrigation plans used for construction must be drawn to scale. The plan must include, at a minimum, the following information: (1) the irrigator's seal, signature, and date of signing; (2) all major physical features and the boundaries of the areas to be watered; (3) a North arrow; (4) a legend; (5) the zone flow measurement for each zone; (6) location and type of each: a. Controller; and b. Sensor (for example, but not limited to, rain, moisture, wind, flow, or freeze); (7) location, type, and size of each: a. Water source, such as, but not limited to a water meter and point(s) of connection; b. Backflow prevention device; c. Water emission device, including, but not limited to, spray heads, rotary sprinkler heads, quick-couplers, bubblers, drip, or micro-sprays; d. Valve, including but not limited to, zone valves, master valves, and isolation valves; e. Pressure regulation component; and f. Main line and lateral piping. (8) The scale used; (9) Irrigation components in any right-of-way shall be clearly indicated on the plan as being installed in the right-of-way. Further, the Irrigator is solely responsible for requesting and complying with all state and local line-locate laws; and, (10) The design pressure.

(Ord. No. 7146, § 2, 12-16-2008)

Ask a question about Amarillo law

Corpus searches the Amarillo sections it holds and shows the ones that match, with their citations. Free, no sign-in.