§ 8-5-27 — Management of fats, oils and grease

Code of Ordinances, City of Amarillo, Texas (Supp. No. 81: codified through Ordinance No. 8226, enacted December 9, 2025) · Amarillo City Code § 8-5-27

Corpus is an independent public-information project, not the official City of Amarillo website. Stable reference: corpuslaw.us/code/021f1775-48bd-4203-8293-819a9a7874b6

Sec. 8-5-27. - Management of fats, oils and grease.

(a) Purpose and Objectives. In order to protect public health, the sanitary sewer system and the overall environment, this section states uniform requirements for fats, oils and grease (FOG) generators and transporters within the City of Amarillo and Amarillo Area Public Health District and enables the City and District to comply with all applicable State and Federal Laws. The objectives of this article are: (1) To aid in the prevention of sanitary sewer overflows resulting from blockages and obstructions due to the accumulation of fats, oils and greases; (2) To promote the proper maintenance of grease traps/interceptors; and (3) To ensure the proper handling and disposal of grease trap waste. (b) Applicability. (1) This section applies only to a covered facility, which means one (1) that is defined as a Food Establishment in section 8-5-1 that: (i) generates fats, oils or greases as a result of food manufacturing, processing, preparation, or food service, and (ii) is a user of either an OSSF or a Publicly Owned Treatment Works (POTW) of a municipality within the District. These facilities include, but are not limited to: Restaurants, food manufactures, food processors, hospitals, schools, hotels and motels, nursing homes, and any other facility preparing, serving, or otherwise making any foodstuff available for human consumption. Provided, however, any such facility that does not produce any Fats, Oils, or Greases as a result of their operation may apply for a variance in 8-5-19 and be declared exempt from the requirements of this section. (2) This section does not apply: (i) to a domestic residence; or (ii) to an industrial facility that discharges fat, oil, grease, or other waste that is subject to regulation by chapter 18-3 of this Code of Ordinances. (c) Requirement; Prohibition; Offense. (1) A covered facility that is subject to the requirements of this section shall install, use, and maintain appropriate grease traps or interceptors as required by this Code. (2) No covered facility may intentionally or unintentionally allow the direct or indirect discharge of any petroleum oil, non-biodegradable cutting oil, mineral oil, or any fats, oils, or greases of animal or vegetable origin: (i) into a POTW system or OSSF in such amounts as to cause interference, obstruction, or blockage in the collection and treatment system, or as to cause pollutants to pass through the treatment works into the environment; or (ii) so as to cause or contribute to a spill, seep, or exposure to fats, oils, grease, or sewage upon or across the land surface. (3) A violation of subsection (1) or (2) is a class C misdemeanor offense of a health and sanitation ordinance, and upon conviction shall be subject to the enhanced fine amounts provided in Section 1-1-5 of this Code of Ordinances. (d) Installation and Maintenance Requirements. (1) New Facility. A covered facility which is newly proposed or constructed, shall be required to design, install, operate and maintain a grease trap or grease interceptor in accordance with locally adopted plumbing codes, this section and any other applicable ordinance or guideline as required by the District. Grease traps/interceptors shall be installed and inspected prior to issuances of a certificate of occupancy and a Food Hygiene permit. (2) Existing Facility. An existing covered facility which will be expanded or extensively renovated for a new or existing business, or that changes owners, shall be required to design, install, operate and maintain a grease trap or grease interceptor in accordance with locally adopted plumbing codes, this section and any other applicable ordinance or guideline as required. Grease traps/interceptors shall be installed and inspected prior to issuances of a certificate of occupancy and a Food Hygiene permit. (3) Maintenance. Each grease trap/interceptor shall be operated and maintained in accordance with the manufacturer's instruction. (e) Design Criteria. In order to meet the requirements of this section, a grease trap/interceptor design shall: (1) Include a sample port of adequate size to facilitate effluent sampling. (2) Be designed and approved to meet nationally developed Standards of Conformance, for example but not limited to: ANSI, PDI, NSF, ASME, UPC. (3) Receive all grease-bearing sources, which shall be routed through a grease trap/interceptor. (4) Be constructed with a minimum of one (1) baffle wall. Hydromechanical units can be used if properly sized and designed by a Licensed Professional Engineer, Master Plumber, the City of Amarillo Environmental Health department, or in certain instances, the product manufacture. The Director of Environmental Health has discretion to require a Licensed Professional Engineer in certain circumstances when deemed necessary. (5) Not receive domestic wastewater or sewage. (6) Be accessible for service by appropriate vehicles and equipment. Accordingly: (i) all feasible effort must be made to place the grease trap/interceptor outside of the structure; (ii) if due to site constraints the unit must be placed within the structure, the grease trap/interceptor must be separated from the interior by means of a corridor; (iii) if (i) or (ii) cannot be met, alternative placements will be reviewed on a case by case basis. (7) Be constructed with Tank Tees on both the inlet and outlet installed to a length of eighteen (18) inches off the bottom. Manufacture specifications differing from this requirement will be accepted if provided in a design cut sheet. (f) Sizing Requirements. (1) Sizing methods must be conducted in accordance with the Amarillo Area Public Health District's locally adopted Grease Interceptor Sizing Worksheet, or the locally adopted plumbing codes. (2) Where sizing formulas result in a calculated grease trap/interceptor volume of less than one thousand (1,000) gallons, a grease trap/interceptor volume of one thousand (1,000) gallons will be required for the installation. (3) A covered facility that proposes to use alternate sizing techniques and/or procedures that result in specifications that differ from the above calculation requirements, must submit alternative plan and calculations to support a proposed alternate grease trap/interceptor size. The alternative method submittal shall include the following minimum information: i. All calculations with recommended sizing for the specific site; ii. Site-specific drawings of the proposed grease trap/interceptor installation to include all service lines and connections. iii. Documentation from the manufacturer showing the ability of the proposed grease trap/interceptor will meet the effluent quality requirements; and iv. Plans and calculations signed and sealed by a Licensed Professional Engineer, Master Plumber or in certain instances, the product manufacture. The Director of Environmental Health has discretion to require a Licensed Professional Engineer in certain circumstances when deemed necessary. (g) Maintenance and Cleaning. (1) Grease trap/interceptor shall be maintained in an efficient operating and sanitary condition and shall be maintained and operated in accordance with the manufacturer's specifications and this section at all times. The introduction of any surfactants, solvents, or emulsifiers into a grease trap that allows the grease to pass from the trap into the collection system, including but not limited to, enzymes, diesel, kerosene, terpene or other solvents is not permitted. (2) All grease trap/interceptor waste shall be properly disposed of by an authorized hauler/transporter and disposed of at a licensed facility. (3) Grease traps/interceptors shall be cleaned as often as necessary to ensure that sediment and floating materials do not accumulate to impair the efficiency of the grease trap/interceptor; to ensure the discharge follows local discharge limits; and to ensure no visible grease is observed in the discharge. (4) Grease traps and grease interceptors subject to this section shall be completely evacuated at a minimum frequency of every ninety (90) days, unless an alternative schedule is determined and approved by the department. In any event, a grease trap/interceptor shall be fully evacuated, cleaned and inspected at least once every three hundred and sixty-five (365) days. (5) A more frequent cleaning schedule may be required when: i. Twenty-five (25) percent or more of the wetted height of the grease trap or grease interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils or greases; or ii. The discharge exceeds BOD, COD, TSS, FOG, pH, or other pollutant levels established by the POTW; or iii. There is a history of non-compliance, generating illicit discharges, sewer backups, or sanitary sewer overflows due to grease deposition in the grease trap, floor drains, or in their servicing city sewer lateral, sewer blockages in the grease trap or downstream of the grease trap in the entities' servicing sewer lateral/sewer main; or iv. If there is evidence of grease pass through and detrimental accumulation in the entities' servicing OSSF, sewer lateral, or sewer main as visualized and recorded by a camera. (6) Grease traps/interceptors of fifty (50) gallon or less capacity may use the following self-cleaning program, subject to any other applicable provision: i. Proper on-site material disposal methods are implemented (e.g. absorb liquids into solid form and dispose of into the solid waste container); ii. Grease trap waste is placed in a leak proof, sealable container(s) located on the premises and in an area for the transporter to service; iii. Detailed records on these activities are maintained in accordance with manifest requirements within this section. (7) Each pump-out of a grease trap/interceptor must be accompanied by a manifest to be used for record keeping purposes and retained by the covered facility. (8) Manifests must be completed and distributed by the transporter as required by State law. (9) Manifests shall be maintained on file by the generator and transporter in accordance with applicable law State law. (10) Periodic grease trap/interceptor inspections will be conducted in conjunction with Food Hygiene or other inspections. All required records must be made available at time of inspection to verify proper maintenance.

(Ord. No. 7865, § 1, 7-28-2020; Ord. No. 8034, § 1, 1-10-2023; Ord. No. 8187, § 4, 4-8-2025; Ord. No. 8207, § 3, 8-26-2025)

Ask a question about Amarillo law

Corpus searches the Amarillo sections it holds and shows the ones that match, with their citations. Free, no sign-in.