§ 1.04 — Adoption of Appendices

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Fire Prevention Chapter, § 1.04

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/3f658127-f339-4995-8bf4-891a534adc0f

Section 1.04 Adoption of Appendices

The following Appendices contained in the International Fire Code, 2021 Edition, are adopted and made a part of this code: 1. Appendix B – entitled FIRE-FLOW REQUIREMENTS FOR BUILDINGS, except that Table B105.2 is hereby amended to change the text of footnote a. to read as follows: a. The reduced fire-flow shall be not less than 1,500 gallons per minute. 2. Appendix E – entitled HAZARD CATEGORIES, in its entirety. 3. Appendix F – entitled HAZARD RANKING, in its entirety. 4. Appendix H – entitled HAZARDOUS MATERIALS MANAGEMENT PLAN AND HAZARDOUS MATERIALS INVENTORY STATEMENT INSTRUCTIONS, in its entirety. 5. Appendix L – entitled REQUIREMENTS FOR FIRE FIGHTER AIR REPLENISHMENT SYSTEMS, is amended in its entirety and shall read as follows: APPENDIX L REQUIREMENTS FOR FIRE FIGHTER AIR REPLENISHMENT SYSTEMS SECTION L101 GENERAL L101.1 Scope. Fire fighter air replenishment systems (FARS) shall be provided in accordance with this appendix and other requirements as determined by the Fire Chief or Fire Code Official. L101.1.1 Where Required – New Buildings. FARS shall be required in all newly constructed buildings that meet any of the following criteria: 1. If the roof assembly is located more than 55 feet above the lowest level of required fire department vehicle access; or 2. If the lowest point of the building is greater than 2 floors below the lowest level of required fire department vehicle access; or 3. If the building exceeds 500,000 sq. ft. of any single, continuous fire area. SECTION L102 DEFINITIONS L102.1 Definitions. For the purpose of this appendix, certain terms are defined as follows: FIRE FIGHTER AIR REPLENISHMENT SYSTEM (FARS). A permanently installed arrangement of piping, valves, fittings, and equipment to facilitate the replenishment of breathing air in self-contained breathing apparatus (SCBA) for fire fighters engaged in emergency operations. SECTION L103 PERMITS L103.1 Permits. Permits shall be required to install, modify, or maintain a FARS. Permits shall be in accordance with Section L103.2 and L103.3. L103.2 Construction permits. A construction permit in accordance with Section 105.6 is required for the installation or modification of a FARS. The construction permit application shall include documentation of an approved acceptance and testing plan as specified in Section L105. L103.3 Operational permits. An operational permit in accordance with Section 105.5 is required to maintain a FARS. SECTION L104 DESIGN AND INSTALLATION L104.1 Design and installation. A FARS shall be designed and installed in accordance with Sections L104.2 through L104.15. L104.2 Standards. FARS shall be in accordance with Sections L104.2.1 and L104.2.2. L104.2.1 Pressurized system components. Pressurized system components shall be designed and installed in accordance with ASME B31.3. L104.2.2 Air quality. The system shall be designed to convey breathing air complying with NFPA 1989. L104.3 Design and operating pressure. The minimum design pressure shall be 4950 psi. The system design pressure shall be marked in an approved manner at the supply connections, and adjacent to pressure gauges on any fixed air supply components. Pressure shall be maintained in the system within 5 percent of the design pressure at all times. L104.4 Cylinder refill rate. The system shall be capable of refilling breathing air cylinders of a size and pressure used by the fire department at a rate of not less than two empty cylinders in two minutes. L104.5 Breathing air supply. The system shall include a stored pressure air supply in accordance with Section L104.5.1 and an external mobile air connection in accordance with Section L104.14. The system shall be arranged so that failure of the stored air supply or any other related component(s) shall not impair the ability of the external mobile air connection to supply air to all connections throughout the building. L104.5.1 Stored pressure air supply. A stored pressure air supply shall be designed based on Chapter 24 of NFPA 1901, with the exception of provisions that only apply to mobile apparatus. The stored pressure air supply shall be capable of refilling not less than 50 empty breathing air cylinders of a size and pressure used by the fire department. L104.5.2 Location. The stored pressure air supply, compressor, and all appurtenances shall be located in the building’s Fire Pump Room. In buildings without a dedicated Fire Pump Room, these components shall be provided in a room with a fire resistive rating of not less than that required of a Fire Pump Room in the same building. The room or area in which the stored air pressure supply and other components are located shall be secured from unauthorized entry; a key box in accordance with Section 506 shall be installed and maintained for entry into this room or area. The stored pressure air supply, compressor, and all appurtenances shall have a minimum of 36 inches of working clearance around all components. L104.6 Isolation valves. System isolation valves that are accessible to the fire department shall be installed on the system riser to allow piping beyond any air cylinder refill panel to be blocked. L104.7 Pressure relief valves. Pressure relief valves shall be installed at each point of supply and at the top or end of each riser. The relief valve shall meet the requirements of CGA S-1.3 and shall not be field adjustable. Pressure relief valves shall discharge in a manner that does not endanger personnel who are in the area. Valves, plugs, or caps shall not be installed in the discharge of a pressure relief valve. Where discharge piping is used, the end shall not be threaded. L104.8 Materials and equipment. Pressurized system components shall be listed and approved for their intended use and rated for the maximum allowable design pressure in the system. Piping and fitting shall be stainless steel. L104.9 Welded connections. Piping connections that are concealed shall be welded. L104.10 Protection of piping. System piping shall be protected from physical damage in an approved manner. System piping, tanks, and all other components shall be securely fastened and/or attached in an approved manner to prevent damage to the system. Penetrations for piping shall comply with Section 703.1 and applicable sections of the International Building Code. L104.11 Compatibility. Fittings and connections intended to be used by the fire department shall be compatible with the fire department’s equipment. If at any time, the fire department changes equipment that is designed to be interfaced with the system, corresponding system fittings and connections shall be changed to be compatible with fire department’s equipment within a timeframe as determined by the Fire Chief or Fire Code Official. L104.12 Security. Connections to a FARS shall be safeguarded from unauthorized access in an approved manner. The room or area in which the stored air pressure supply and other components are located shall be secured from unauthorized entry; a key box in accordance with Section 506 shall be installed and maintained for entry into this room or area. L104.13 Fill stations. Fire fighter air replenishment fill stations shall comply with Section L104.13.1 through L104.13.3. L104.13.1 Locations. Fill stations for refilling breathing air cylinders shall be located as follows: 1. Fill stations shall be provided adjacent to all standpipe connections in multi-story buildings meeting the criteria of Section L101.1.1 #1, starting on the second floor above the lowest level of required fire vehicle access, and continuing thereafter. 2. Fill stations shall be provided adjacent to all standpipe connections in sub-grade buildings meeting the criteria of Section L101.1.1 #2, starting on the second floor below the lowest level of required fire vehicle access, and continuing thereafter. 3. Fill stations shall be provided adjacent to all standpipe connections in buildings meeting criteria of Section L101.1.1 #3. L104.13.2 Design. Fill stations for breathing air cylinders shall be designed to meet the following requirements: 1. A pressure gauge and pressure-regulating devices and controls shall be provided to allow the operator to control the fill pressure and fill rate on each cylinder fill hose. 2. Valves controlling cylinder fill hoses shall be slow-operating valves. 3. A separate flow restriction device shall be provided on each fill hose. 4. An approved method shall be provided to bleed each cylinder fill hose. 5. All fill stations shall provide for the direct refilling of the fire fighters’ breathing air cylinder using Rapid Intervention Crew/Company Universal Air Connection (RIC/UAC) fittings in lieu of cylinder fill stations that utilize containment areas. Unless otherwise authorized by the Fire Chief or Fire Code Official, fill stations that utilize containment areas are not allowed. L104.13.3 Cylinder fill rate. Fill stations shall be capable of simultaneously filling two or more empty breathing air cylinders equivalent to those used by the fire department to the cylinders’ design pressure within 2 minutes. L104.14 External mobile air connection. An external mobile air connection shall be provided. L104.14.1 Location. External mobile air connections shall be located adjacent to the building’s fire department connection at a reasonable height and position, as determined by the Fire Code Official. When the fire department connection is located remotely away from the building, the external mobile air connection shall be located adjacent to the entry door to the Riser/Pump Room at a reasonable height and position, as determined by the Fire Code Official or in another location as approved by the Fire Chief or Fire Code Official. L104.14.2 Protection from vehicles. A means of vehicle impact protection in accordance with Section 312 shall be provided to protect mobile air connections that are subject to vehicular impact. L104.14.3 Clear working space. A working space of not less than 36 inches in width, 36 inches in depth, and 78 inches in height shall be provided and maintained in front of and to the sides of external mobile air connections. L104.15 Air monitoring system. An approved air monitoring system shall be provided. The system shall automatically monitor air quality, moisture and pressure on a continual basis. The air monitoring system shall be equipped with not less than two content analyzers capable of detecting carbon monoxide, carbon dioxide, nitrogen, oxygen, moisture, and hydrocarbons. L104.15.1 Alarm conditions. The air monitoring system shall automatically transmit a supervisory signal when any of the following levels are detected: 1. Carbon monoxide exceeds 5 ppm. 2. Carbon dioxide exceeds 1,000 ppm. 3. Any oxygen level below 19.5 percent or above 23.5 percent. 4. A nitrogen level below 75 percent or above 81 percent. 5. Hydrocarbon (condensed) content exceeds 5 milligrams per cubic meter of air. 6. Moisture concentration exceeds 24 ppm by volume. 7. The pressure falls below 95 percent of the maintenance pressure specified in Section L104.3. L104.15.2 Alarm supervision, monitoring, and notification. The air monitoring system shall be electrically supervised by the building’s fire alarm system and shall be monitored by an approved central station. Alarm conditions shall automatically transmit a supervisory signal to the fire alarm control panel and shall produce an audible and visual alarm. L104.15.3 Air quality status display. Air quality status shall be visually displayed at the external mobile air connection required by Section L104.14. SECTION L105 ACCEPTANCE TESTS L105.1 Acceptance tests. Upon completion of the installation, every system or modification of an existing system shall be acceptance tested to verify compliance with equipment manufacturers’ instructions and design documents. Oversight of the acceptance tests shall be provided by a registered design professional who designed the system and is knowledgeable of the system’s components and operation. The Fire Code Official shall also be present for all acceptance tests. Testing shall include, but not be limited to, all of the following: 1. A pneumatic test in accordance with ASME B31.3 of the complete system at minimum test pressure of 110 percent of the system design pressure using oil free dry air, nitrogen, or argon shall be conducted. Test pressure shall be maintained for not less than 24 hours. During this test, all fittings, joints, and system components shall be inspected for leaks. Defects in the system or leaks detected shall be documented and repaired. A leak or failure of the system shall yield in another inspection in accordance with this section. 2. A cylinder-filling performance test shall be conducted to verify compliance with the required breathing air cylinder refill rate from the exterior mobile air connection and a stored air pressure supply system. 3. The air quality monitoring system shall be tested to verify both of the following conditions: 3.1 Visual indicators required by Section L104.15.1 function properly. 3.2 Supervisory signals are transmitted as required by Section L104.15.2 for each sensor based on a sensor function test. 4. Connections intended for fire department use shall be confirmed as compatible with the fire department’s mobile air unit, SCBA cylinders, and RIC/UAC connections. 5. Air samples shall be taken from not less than two fill stations and submitted to an approved gas analysis laboratory to verify compliance with NFPA 1989. The FARS shall not be placed into service until a written report verifying compliance with NFPA 1989 has been provided to the Fire Code Official. SECTION L106 INSPECTION, TESTING, AND MAINTENANCE L106.1 Periodic inspection, testing, and maintenance. A FARS shall be continuously maintained in an operative condition and shall be inspected not less than annually. Not less than quarterly, an air sample shall be taken from the system and tested to verify compliance with NFPA 1989. The laboratory test results shall be maintained on site with the FARS and shall also be sent to the Fire Code Official. SECTION L107 REFERENCED STANDARDS ASME B31.3 – 2020 Process Piping CGA S-1.3 – 2008 Pressure Relief Device Standards NFPA 1901 – 2016 Standard for Automotive Fire Apparatus NFPA 1989 – 2013 Breathing Quality for Fire Emergency Services Respiratory Protection

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.