Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Construction Chapter, § 1.04

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/b02ee10d-5489-4e9a-8440-0e942b6180e2

Section 1.04 Amendments, Additions and Deletions

The adoption of the I.B.C, I.E.B.C., I.R.C., I.E.C.C., and I.S.P.S.C. as provided in Section 1.02 above, is modified and amended by the following: A. The addition thereto of Articles II, et seq., of this Chapter. B. The above-referenced codes are subject to the local amendments adopted herein and found at the following subsections: International Building Code, see Subsection C International Residential Code, see Subsection D International Energy Conservation Code, see Subsection E International Existing Building Code, see Subsection F International Swimming Pool and Spa Code, see Subsection G C. The following local amendments to the International Building Code (I.B.C.) are hereby adopted: 1. The amendment of Section 101.1, entitled Title., to read as follows: Section 101.1 Title. These regulations shall be known as the Building Codes of the City of Arlington, Texas, hereinafter referred to as "this code." 2. The amendment of the exceptions to Section 101.2, entitled Scope., to read as follows: Exceptions: 1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress and their accessory structures shall comply with the International Residential Code. 2. Portable and/or temporary storage buildings not exceeding three hundred twenty (320) square feet in area shall not be subject to the provisions of this Building Code for foundations and framing provided: (a) The building shall not be intended or used for human occupancy; (b) No plumbing and/or mechanical improvements shall be permitted, and any electrical improvements are supervised by permits and work shall be installed in full compliance with the appropriate Chapter of the Code of the City of Arlington for such work; and (c) A permit for such building shall have been obtained from the Building Official. 3. The amendment of Section 101.4, entitled Referenced codes., to read as follows: 101.4 Referenced codes. The other codes listed in Sections 101.4.1 through 101.4.8, and referenced elsewhere in this code, when specifically adopted, shall be considered part of the requirements of this code to the prescribed extent of each such reference. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the Electrical Code shall mean the Electrical Code as adopted. 4. The amendment of Section 101.4.8, entitled Electrical, to read as follows: 101.4.8 Electrical. The provisions of the Electrical Code shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto. 5. The amendment of Section 103 and 103.1, to read as follows: SECTION 103 DIVISION OF BUILDING INSPECTIONS 103.1 Creation of enforcement agency. The Division of Building Inspections is hereby created and the official in charge thereof shall be known as the Building Official. 6. The amendment of Section 104.6, entitled Right of entry., to read as follows: 104.6 Right of entry Where it is necessary to make an inspection to enforce any of the provisions of this Building Code, or whenever the Building Official or an authorized representative has reasonable cause to believe that there exists in any building or upon any premises any condition or violation which makes such building or premises unsafe, dangerous or hazardous, the Building Official or an authorized representative may enter such building or premises at all reasonable times to inspect the same or to perform any duty imposed upon said Building Official by this Building Code. If such building or premises is occupied, the Building Official or an authorized representative shall first present proper credentials and request entry. If such building or premises is unoccupied, the Building Official shall first make a reasonable effort to locate the owner or other person having charge or control of the building or premises and request entry. If such entry is refused, or, if no owner or other person having charge or control of the building or premises can be located, the Building Official or an authorized representative shall have recourse to every remedy provided by law to secure entry. 7. The deletion of Section 104.10.1, entitled Flood hazard areas, in its entirety. 8. The addition of Section 104.12, entitled Occupancy violations., which shall read as follows: 104.12 Occupancy violations. Whenever any building, structure, or equipment therein which is regulated by this Building Code is being used contrary to the provisions of said Code, the Building Official or an authorized representative may order that such use be discontinued and/or that the building or structure, or a portion thereof, be vacated by written notice served on any person who is causing such use to be continued. Further, the Building Official or an authorized representative may order the evacuation of any building or premises, or a portion thereof, which constitutes a dangerous building as defined in Article XVI of this Chapter. Notice to stop use shall be given by personal delivery or by certified mail, return receipt requested, to the person responsible for the continued use. Such person shall discontinue the use within the time prescribed by the Building Official after receipt of such notice and shall not resume the use of the building or premises until first rendering the same in compliance with this Building Code. Notice to vacate a dangerous building or premises shall be posted at or upon each exit of the said structure affected thereby, and shall be in substantially the following form: "DO NOT ENTER UNSAFE TO OCCUPY It is a misdemeanor to occupy this building, or to remove or deface this notice. Arlington Building Official (by)______________________________ (date)____________________________ (compliance due date) _____________" No person shall remain in or enter any building or premises which has been so posted, except that entry may be made to repair, demolish or remove the unsafe condition. Such entry or the destruction, defacing or removal of said notice prior to approval by the Building Official or an authorized representative shall be a violation of this Building Code. 9. The amendment of Section 105, entitled PERMITS, by deleting in its entirety. 10. The amendment of Section 107, entitled CONSTRUCTION DOCUMENTS, by deleting in its entirety. 11. The amendment of Section 109, entitled FEES, by adding Section 109.7, entitled Re-inspection fee, which shall read as follows: 109.7 Re-inspection fee. A fee as established by city council resolution may be charged when: 1. The inspection called for is not ready when the inspector arrives; 2. No building address or permit card is clearly posted; 3. City approved plans are not on the job site available to the inspector; 4. The building is locked or work otherwise not available for inspection when called; 5. The job site is red-tagged twice for the same item; 6. The original red tag has been removed from the job site; or 7. Failure to maintain erosion control, trash control or tree protection. Any re-inspection fees assessed shall be paid before any more inspections are made on that job site. 12. The amendment of Section 109, entitled FEES, by adding Section 109.8, entitled Work without a permit, and subsections 109.8.1 and 109.8.2, which shall read as follows: 109.8 Work without a permit. 109.8.1 Investigation. Whenever work for which a permit is required by this code has been commenced without first obtaining a permit, a special investigation shall be made before a permit may be issued for such work. 109.8.2 Work without a permit Fee. A work without a permit fee, in addition to the permit fee, shall be collected whether or not a permit is subsequently issued. The work without a permit fee shall be equal to the amount of the permit fee required by this code or the city fee schedule as applicable. The payment of such work without a permit fee shall not exempt the applicant from compliance with all other provisions of either this code or the technical codes nor from penalty prescribed by law. 13. The amendment of Section 110, entitled INSPECTIONS, by deleting in its entirety. 14. The amendment of Section 111, entitled CERTIFICATE OF OCCUPANCY, by deleting in its entirety. 15. The amendment of Section 113, entitled MEANS OF APPEALS, by deleting in its entirety. 16. The amendment of Section 114, entitled VIOLATIONS, by deleting in its entirety. 17. The amendment of Section 115, entitled STOP WORK ORDER, to read as follows: SECTION 115 STOP WORK ORDER 115.1 Stop Work Order. Whenever any work is being done contrary to the provisions of this Code, the Building Official may order the work stopped by notice in writing served on any persons engaged in the doing or causing such work to be done. Any such person shall forthwith stop such work until: a. He or she is authorized by the Building Official to proceed with the work; or b. An appeal perfected pursuant to Section 2.06 of Article II has resulted in a waiver of the condition causing the stop order, or a finding that there is no cause for a stop order. Failure to stop such work, in addition to penalties and remedies elsewhere set forth, shall void any appeal. 18. The amendment of Section 116, entitled UNSAFE STRUCTURES AND EQUIPMENT, by deleting in its entirety. 19. The amendment of Section 202, entitled DEFINITIONS, by amending the definitions of AMBULATORY CARE FACILITY, ASSISTED LIVING FACILITY, REPAIR GARAGE, and SPECIAL INSPECTOR to read as follows: AMBULATORY CARE FACILITY. Buildings or portions thereof used to provide medical, surgical, psychiatric, nursing or similar care on a less than 24-hour basis to persons who are rendered incapable of self-preservation by the services provided or staff has accepted responsibility for care recipients already incapable. This group may include but is not to be limited to the following: - Dialysis centers - Sedation dentistry - Surgery centers - Colonic centers - Psychiatric centers ASSISTED LIVING FACILITIES. A building or part thereof housing persons, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment which provides personal care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. REPAIR GARAGE. A building, structure or portion thereof used for servicing or repairing motor vehicles. This occupancy shall also include garages involved in minor repair, modification and servicing of motor vehicles for items such as lube changes, inspections, windshield repair or replacement, shocks, minor part replacement and other such minor repairs. SPECIAL INSPECTOR. A qualified person employed or retained by an approved agency who shall prove to the satisfaction of the registered design professional in responsible charge and approved by the Building Official as having the competence necessary to inspect a particular type of construction requiring special inspection. 20. The amendment of Section 303.1.3, entitled Associated with Group E occupancies, to read as follows: 303.1.3 Associated with Group E occupancies. A room or space used for assembly purposes that is associated with a Group E occupancy is not considered a separate occupancy, except when applying the assembly requirements of Chapter 10 and 11. 21. The amendment of Section 304.1, entitled Business Group B., by adding the following two items to the list of occupancies listed therein: Fire stations Police stations with detention facilities for 5 or less 22. The amendment of Section 307.1.1, entitled Uses other than Group H, by amending Exception 4 to read as follows: 4. Cleaning establishments that utilize combustible liquid solvents having a flash point of 140°F (60°C) or higher in closed systems employing equipment listed by an approved testing agency, provided that this occupancy is separated from all other areas of the building by 1-hour fire barriers constructed in accordance with Section 707, or 1-hour horizontal assemblies constructed in accordance with Section 711, or both. See also Chapter 21, Dry Cleaning Plant provision of the Fire Code. 23. The amendment of Section 403.1, entitled Applicability, to amend Exception 3 to read as follows: 3. The open air portion of a building containing a Group A-5 occupancy in accordance with Section 303.6. 24. The amendment of Section 403.3, entitled Automatic Sprinkler System., by deleting the Exception. 25. The amendment of Section 403.3.2, entitled Water supply to required fire pumps, to read as follows: 403.3.2 Water supply to required fire pumps. In buildings that are more than 120 feet (36.5 m) in building height, required fire pumps shall be supplied by connections to no fewer than two water mains located in different streets. Separate supply piping shall be provided between each connection to the water main and the pumps. Each connection and the supply piping between the connection and the pumps shall be sized to supply the flow and pressure required for the pumps to operate. Exception: Two connections to the same main shall be permitted provided that the main is valved such that an interruption can be isolated so that the water supply will continue without interruption through no fewer than one of the connections. 26. The amendment of Section 404.10, entitled Exit stairways in an atrium, to read as follows: Section 404.10 Exit Stairways in an atrium. Where an atrium contains an interior exit access stairway all the following shall be met: 1. The entry of the exit stairway is the edge of the closest riser of the exit stairway. 2. The entry of the exit stairway shall have access from a minimum of two directions. 3. The distance between the entry to an exit stairway in an atrium and the entrance to a minimum of one exit stairway enclosed in accordance with Section 1023.2 shall comply with the separation required by Section 1007.1.1. 4. Exit access travel distance shall be measured to the closest riser of the exit stairway. 5. Not more than 50 percent of the exit stairways shall be located in the same atrium. 27. The amendment of Section 406.3.3.1, entitled Carport separation, to read as follows: 406.3.3.1 Carport Separation A separation is not required between a Group R-3 and U carport, provided that the carport is entirely open on two or more sides and there are not enclosed areas above. A fire separation is not required between a Group R-2 and U carport, provided that the carport is entirely open on all sides and that the distance between the two is at least 10 feet (3048 mm). 28. The amendment of Section 423.5.1, entitled Required occupant capacity, to read as follows: 423.5.1 Required occupant capacity. The required occupant capacity of the storm shelter shall include all of the buildings on the site and shall be the greater of the following: 1. The total occupant load of the classrooms, vocational rooms and offices in the Group E occupancy. 2. The occupant load of the largest indoor assembly space that is associated with the Group E occupancy. Exceptions: 1. Where a new building is being added on an existing Group E site, and where the new building is not of sufficient size to accommodate the required occupant capacity of the storm shelter for all of the buildings on the site, the storm shelter shall at a minimum accommodate the required occupant capacity for the new building. 2. Where approved by the building official, the required occupant capacity of the shelter shall be permitted to be reduced by the occupant capacity of any existing storm shelters on the site. 3. Where approved by the building official, the actual number of occupants for whom each occupied space, floor or building is designed, although less than those determined by occupant load calculation, shall be permitted to be used in the determination of the required design occupant capacity for the storm shelter. 29. The amendment of Section 503.1., entitled General, to read as follows: 503.1. General. Unless otherwise specifically modified in Chapter 4 and this chapter, building height, number of stories and building area shall not exceed the limits specified in Section 504 and 506 based on the type of construction as determined by Section 602 and the occupancies as determined by Section 302 except as modified hereinafter. Building height, number of stores and building area provisions shall be applied independently. For the purposes of determining area limitations, height limitations and type of construction, each portion of a building separated by one or more fire walls complying with Section 706 shall be considered to be a separate building. Where a building contains more than one distinct type of construction, the building shall comply with the most restrictive area, height, and stories, for the lesser type of construction or be separated by fire walls, except as allowed in Section 510. 30. The amendment of Section 506.2, entitled Allowable area determination, by amending Table 506.2, entitled ALLOWABLE AREA FACTOR IN SQUARE FEET by deleting footnote "i" in its entirety. 31. The amendment of Section 506.3.1, entitled Minimum percentage of perimeter, to read as follows: 506.3.1 Minimum percentage of perimeter. To qualify for an area factor increase based on frontage, a building shall have not less than 25 percent of its perimeter on a public way or open space. Such open space shall be either on the same lot or dedicated for public use and shall be accessed from a street or approved fire lane. In order to be considered as accessible, if not in direct contact with a street or fire lane, a minimum 10-foot-wide pathway meeting fire department access from the street or approved fire lane shall be provided. 32. The amendment of Section 708.4.2, entitled Fireblocks and draftstops in combustible construction., to read as follows: 708.4.2 Fireblocks and draftstops in combustible construction. In combustible construction where fire partitions do not extend to the underside of the floor or roof sheathing, deck or slab above, the space above and along the line of the fire partition shall be provided with one of the following: 1. Fireblocking up to the underside of the floor or roof sheathing, deck or slab above using materials complying with Section 718.2.1. 2. Draftstopping up to the underside of the floor or roof sheathing, deck or slab above using materials complying with Section 718.3.1 for floors or Section 718.4.1 for attics. Exceptions: 1. Buildings equipped with an automatic sprinkler system installed throughout in accordance with Section 903.3.1.1, or in accordance with Section 903.3.1.2 provided that sprinkler protection is provided in the space between the top of the fire partition and the underside of the floor or roof sheathing, deck or slab above as required for systems complying with Section 903.3.1.1. Portions of buildings containing concealed spaces filled with noncombustible insulation as permitted for sprinkler omission shall not apply to this exception for draftstopping. 2. Where corridor walls provide a sleeping unit separation, draftstopping shall only be required above one of the corridor walls. 3. In Group R-2 occupancies with fewer than four dwelling units, fireblocking and draftstopping shall not be required. 4. In Group R-2 occupancies up to and including four stories in height in buildings not exceeding 60 feet (18 288 mm) in height above grade plane, the attic space shall be subdivided by draftstops into areas not exceeding 3,000 square feet (279 m2) or above every two dwelling units, whichever is smaller. 5. In Group R-3 occupancies with fewer than three dwelling units, fireblocking and draftstopping shall not be required in floor assemblies. 33. The amendment of Section 718.3, entitled Draftstopping in floors, by amending the Exception to read as follows: Exception: Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. and provided that in combustible construction, sprinkler protection is provided in the floor space. 34. The amendment of Section 718.4, entitled Draftstopping in attics, by amending the Exception to read as follows: Exception: Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and provided that in combustible construction, sprinkler protection is provided in the attic space. 35. The amendment of Section 901.6.1, entitled Automatic sprinkler systems, by adding Section 901.6.1.1, entitled Standpipe testing, which shall read as follows: 901.6.1.1 Standpipe Testing. Building owners/managers must maintain and test standpipe systems as per NFPA 25 requirements. The following additional requirements shall be applied to the testing that is required every 5 years: 1. The piping between the Fire Department Connection (FDC) and the standpipe shall be backflushed when foreign material is present, and also hydrostatically tested for all FDC’s on any type of standpipe system. Hydrostatic testing shall also be conducted in accordance with NFPA 25 requirements for the different types of standpipe systems. 2. For any manual (dry or wet) standpipe system not having an automatic water supply capable of flowing water through the standpipe, the tester shall connect hose from a fire hydrant or portable pumping system (as approved by the fire code official) to each FDC, and flow water through the standpipe system to the roof outlet to verify that each inlet connection functions properly. Confirm that there are no open hose valves prior to introducing water into a dry standpipe. There is no required pressure criteria at the outlet. Verify that check valves function properly and that there are no closed control valves on the system. 3. Any pressure relief, reducing, or control valves shall be tested in accordance with the requirements of NFPA 25. All hose valves shall be exercised. 4. If the FDC is not already provided with approved caps, the contractor shall install such caps for all FDC’s as required by the fire code official. 5. Upon successful completion of standpipe test, place a blue tag (as per Texas Administrative Code, Fire Sprinkler Rules for Inspection, Test and Maintenance Service (ITM) Tag) at the bottom of each standpipe riser in the building. The tag shall be check-marked as "Fifth Year" for Type of ITM, and the note on the back of the tag shall read "5 Year Standpipe Test" at a minimum. 6. The procedures required by Texas Administrative Code Fire Sprinkler Rules with regard to Yellow Tags and Red Tags or any deficiencies noted during the testing, including the required notification of the local Authority Having Jurisdiction (fire code official) shall be followed. 7. Additionally, records of the testing shall be maintained by the owner and contractor, if applicable, as required by the State Rules mentioned above and NFPA 25. 8. Standpipe system tests where water will be flowed external to the building shall not be conducted during freezing conditions or during the day prior to expected night time freezing conditions. 9. Contact the fire code official for requests to remove existing fire hose from Class II and III standpipe systems where employees are not trained in the utilization of this firefighting equipment. All standpipe hose valves must remain in place and be provided with an approved cap and chain when approval is given to remove hose by the fire code official. 36. The amendment of Section 902.1, entitled Pump and riser room size, to be retitled Pump and riser room size and location, and shall read as follows: 902.1 Pump and riser room size and location. All pump and riser rooms shall be provided on the ground floor or other approved level of fire department apparatus access and with a door directly accessible from the exterior of the building in an approved location. The door must be labeled as the "RISER ROOM" by an approved method. All sprinkler riser rooms shall provide adequate work-around room between fire protection equipment and any interior/exterior walls, obstructions, or other equipment. The minimum spacing around all fire protection equipment, piping, valves, etc. shall be no less than 36 inches from all functional sides. Fire pump and riser rooms shall be provided with a door[doors] and an unobstructed entry/exit passageway large enough to allow removal of the largest piece of equipment. A key box complying with Section 506.1 shall be installed at the fire sprinkler riser and/or pump room. Additional safeguards shall be provided as determined by the Fire Code Official. 37. The amendment of Section 903.1.1, entitled Alternative protection, to read as follows: 903.1.1 Alternative protection. Alternative automatic fire-extinguishing systems complying with Section 904 shall be permitted in addition to automatic sprinkler protection, where recognized by the applicable standard and approved by the fire code official. 38. The amendment of Section 903.2, entitled Where required, by adding additional language and deleting the Exception, so that the section shall read as follows: Section 903.2 Where required Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections 903.2.1 through 903.2.12. Automatic Sprinklers shall not be installed in elevator machine rooms, elevator machine spaces, and elevator hoistways, other than pits where such sprinklers would not necessitate shunt trip requirements under any circumstances. Storage shall not be allowed within the elevator machine room. Signage shall be provided at the entry doors to the elevator machine room indicating "ELEVATOR MACHINERY – NO STORAGE ALLOWED. " 39. The addition of Section 903.2.1.8, entitled Special amusement building, to read as follows: 903.2.1.8 Special amusement building. Special amusement buildings shall be equipped throughout with an automatic sprinkler system. Exception: An automatic sprinkler system need not be provided when an amusement building shall be in existence less than 30 continuous days and when the construction and use is approved by the Fire Code Official. 40. The amendment of Section 903.2.4, entitled Group F-1, to read as follows: 903.2.4 Group F-1. An automatic sprinkler system shall be provided throughout all buildings where the fire area containing a Group F-1 occupancy exceeds 12,000 square feet (1115 m2), or where more than two stories in height, or where the combined fire area on all floors, including mezzanines, exceeds 24,000 square feet (2230 m2). 41. The amendment of Section 903.2.4.2, entitled Group F-1 distilled spirits, to read as follows: 903.2.4.2 Group F-1 distilled spirits. An automatic sprinkler system shall be provided throughout a Group F-1 fire area used for the manufacture of distilled spirits involving more than 120 gallons of distilled spirits (>16% alcohol) in the fire area at any one time. 42. The amendment of Section 903.2.8, entitled Group R, to read as follows: 903.2.8 Group R. An automatic sprinkler system shall be installed throughout all buildings with a Group R fire area. One- and two-family dwellings, Group R-3; Group R- 4 Condition 1; and townhouses not exceeding two stories in height shall be permitted to comply with Section 903.3.1.3. Buildings up to and including four stories in height, not exceeding 60 feet in height above the lowest level of fire apparatus access, shall be permitted to comply with Section 903.3.1.2. All other buildings with a Group R fire area shall comply with Section 903.3.1.1. 43. The amendment of Section 903.2.8.3, entitled Group R-4 Condition 2, to read as follows: 903.2.8.3 Group R-4 Condition 2. An automatic sprinkler system installed in accordance with Section 903.3.1.2 shall be permitted in Group R-4 Condition 2 occupancies. 44. The amendment of Section 903.2.9.3, entitled Group S-1 distilled spirits or wine, to read as follows: 903.2.9.3 Group S-1 distilled spirits or wine. An automatic sprinkler system shall be provided throughout a Group S-1 fire area used for the bulk storage of distilled spirits or wine involving more than 120 gallons of distilled spirits or wine (>16% alcohol) in the fire area at any one time. 45. The amendment of Section 903.2.9.4, entitled Group S-1 upholstered furniture and mattresses, by deleting the Exception in its entirety. 46. The amendment of Section 903.2.9, entitled Group S-1, by adding Section 903.2.9.5, entitled Self-service storage facility, which shall read as follows: 903.2.9.5 Self-Service Storage Facility. An automatic sprinkler system shall be installed throughout all self-service storage facilities. Exception: One-story self-service storage facilities that have no interior corridors, with at least a one-hour fire barrier separation wall installed between every storage compartment. 47. The amendment of Section 903.2.11.3, entitled Buildings 55 feet or more in height, by deleting the Exception and amending the section to read as follows: 903.2.11.3 Buildings 55 feet or more in height. An automatic sprinkler system shall be installed throughout buildings that have one or more stories other than penthouses in compliance with Section 1510 of the International Building Code, located 55 feet (16 764 mm) or more above the lowest level of fire department vehicle access, measured to the finished floor. 48. The amendment of Section 903.2.11, entitled Specific building areas and hazards, by adding Section 903.2.11.7 and Section 903.2.11.8, which shall read as follows: 903.2.11.7 High-Piled Combustible Storage. For any building with a clear height exceeding 12 feet (4572 mm), see Chapter 32 of the International Fire Code to determine if those provisions apply. 903.2.11.8 Spray Booths and Rooms. New and existing spray booths and spraying rooms shall be protected by an approved automatic fire-extinguishing system. 49. The amendment of Section 903.3.1.1, entitled NFPA 13 sprinkler systems, to read as follows: 903.3.1.1 NFPA 13 sprinkler systems. Where the provisions of this code require that a building or portion thereof be equipped throughout with an automatic sprinkler system in accordance with this section, sprinklers shall be installed throughout in accordance with NFPA 13, with the exclusion of Section 8.15.8 of that standard, and except as provided in Sections 903.3.1.1.1 and 903.3.1.1.2. 50. The amendment of Section 903.3.1.1.1, entitled Exempt locations, to read as follows: 903.3.1.1.1 Exempt locations. Where approved by the Fire Code Official, sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire alarm system in accordance with Section 907.2. Sprinklers shall not be omitted from any room or area merely because of the following circumstances: the potential water damage from sprinkler activation; the fire- resistance-rated construction of the room or area; or that a room or area contains electrical equipment. 1. Any room where the application of water constitutes a serious life or fire hazard. 2. Any room or area where sprinklers are considered undesirable because of the nature of the contents within that room or area. 3. Generator or transformer rooms, under the direct control of a public utility, separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance-rating of not less than two hours. 4. Machine rooms, elevator machinery spaces, control rooms, control spaces, and elevator hoist ways. Buildings and portions thereof shall be considered to be covered by an automatic sprinkler system throughout and in compliance with this code if they contain areas that are not required to have sprinkler coverage by this code, or any other locations as approved by the Fire Code Official. 51. The amendment of Section 903.3.1.2, entitled NFPA 13R sprinkler systems, to read as follows: 903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinkler systems in Group R occupancies shall be permitted to be installed throughout in accordance with NFPA 13R where the Group R occupancy meets all of the following conditions: 1. Four stories or less above grade plane. 2. The floor level of the highest story is 35 feet (10668 mm) or less above the lowest level of fire department vehicle access. 3. The floor level of the lowest story is 35 feet (10668 mm) or less below the lowest level of fire department vehicle access. The number of stories of Group R occupancies constructed in accordance with Section 510.2 and 510.4 shall be measured from grade plane. 52. The amendment of Section 903.3.1.2.1, entitled Balconies and decks, to read as follows: 903.3.1.2.1 Balconies and decks. Dry or antifreeze sidewall sprinkler protection shall be provided for exterior balconies, decks, and ground floor patios of buildings protected by a system complying with Section 903.3.1.2, provided there is a roof or deck above. Sidewall sprinklers that are used to protect such areas shall be permitted to be located such that their deflectors are within 1 inch to 6 inches below the structural members and a maximum distance of 14 inches below the deck above. 53. The amendment of Section 903.3.1.2.2, entitled Corridors and balconies in the means of egress, to read as follows: 903.3.1.2.2 Corridors and balconies in the means of egress. Sprinkler protection shall be provided in all corridors and for all balconies. 54. The amendment of Section 903.3.1.2.3, entitled Attics, by deleting said section in its entirety and replacing with the following to read as follows: Section 903.3.1.2.3 Attached Garages and Attics. Sprinkler protection is required in attached garages, and in the following attic spaces: 1. Attics that are used or intended for living purposes or storage shall be protected by an automatic sprinkler system. 2. Where fuel-fired equipment is installed in an un-sprinklered attic, not fewer than one quick-response intermediate temperature sprinkler shall be installed above the equipment. 3. Attic spaces of buildings that are two or more stories in height above grade plane or above the lowest level of fire department vehicle access. 4. Group R-4, Condition 2 occupancy attics not required by Item 1 or 3 to have sprinklers shall comply with one of the following: 4.1. Provide automatic sprinkler system protection. 4.2. Provide a heat detection system throughout the attic that is arranged to activate the building fire alarm system. 4.3. Construct the attic using noncombustible materials. 4.4. Construct the attic using fire-retardant-treated wood complying with Section 2303.2 of the International Building Code. 4.5. Fill the attic with noncombustible insulation. 55. The amendment of Section 903.3.1.3, entitled NFPA 13D sprinkler systems, to read as follows: 903.3.1.3 NFPA 13D sprinkler systems. Automatic sprinkler systems installed in one- and two-family dwellings; Group R-3; Group R-4, Condition 1; and townhouses shall be permitted to be installed throughout in accordance with NFPA 13D or in accordance with state law. 56. The amendment of Section 903.3.1, entitled Standards, by adding Section 903.3.1.4, entitled Multipurpose sprinkler systems, which shall read as follows: 903.3.1.4 Multipurpose sprinkler systems. Can be used for one- and two-family dwellings where one structure is located on a dedicated lot. The structures must also have a minimum of 10’ horizontal separation between roof line edges. 57. The amendment of Section 903.3.1, entitled Standards, by adding Section 903.3.1.5, entitled Freeze protection, et seq., which shall read as follows: 903.3.1.5 Freeze protection. Freeze protection systems for automatic fire sprinkler systems shall be in accordance with the requirements of the applicable referenced NFPA standard and this section. 903.3.1.5.1 Attics. Only dry pipe, preaction, or listed antifreeze automatic fire sprinkler systems shall be allowed to protect attic spaces. Exception: Wet-pipe fire sprinkler systems shall be allowed to protect non-ventilated attic spaces where: 1. The attic sprinklers are supplied by a separate floor control valve assembly to allow ease of draining the attic system without impairing sprinklers throughout the rest of the building, and 2. Adequate heat shall be provided for freeze protection as per the applicable referenced NFPA standard, and 3. The attic space is a part of the building’s thermal, or heat, envelope, such that insulation is provided at the roof deck, rather than at the ceiling level. 903.3.1.5.2 Heat trace/insulation. Heat trace/insulation shall only be allowed where approved by the fire code official for small sections of large diameter water-filled pipe. 58. The amendment of Section 903.3.5, entitled Water supplies, by adding a second paragraph, which shall read as follows: Water supply as required for such systems shall be provided in conformance with the supply requirements of the respective standards; however, every water-based fire protection system shall be designed with a 10-psi safety factor. Reference Section 507.4 for additional design requirements. 59. The amendment of Section 903.3.5, entitled Water supplies, by adding Section 903.3.5.3, entitled Aboveground water supply vaults/housings, which shall read as follows: 903.3.5.3 Aboveground water supply vaults/housings. All new service mains for supplying water to fire protection systems that continue in aboveground vaults or housings shall be protected against freezing and impact damage. All new vaults or housings with aboveground water supplies, including backflow prevention assemblies, shall be provided with a reliable heat source or other method to protect the piping/assemblies from freezing. All new vaults shall be protected from vehicle impact by means in accordance with Section 312. 60. The amendment of Section 903.3.7, entitled Fire department connections, by adding Section 903.3.7.1, entitled Additional connections, which shall read as follows: 903.3.7.1 Additional connections. If required fire flow requirements exceed the initial 1500 G.P.M. for any system, building, or portion thereof, an additional fire department connection complying with this section shall be provided for each additional 1500 G.P.M. or fraction thereof. If a single additional connection is required by this section and if provided in a manifold, the supply piping from the manifold to the sprinkler system shall be a minimum of 6 inches. If two additional connections are required by this section and if provided in a manifold, the supply piping from the manifold to the sprinkler system shall be a minimum of 8 inches. For three or more additional connections, and for any arrangement of manifolded fire department connections, the supply piping to the system shall be capable of supplying the aggregate volume of incoming water. 61. The amendment of Section 903.4, entitled Sprinkler system supervision and alarms, by adding a second paragraph after the exceptions, which shall read as follows: Sprinkler and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for more than 45 seconds. All control valves in the sprinkler and standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a supervisory signal at the central station upon tampering. 62. The amendment of Section 903.4.2, entitled Alarms, to read as follows: 903.4.2 Alarms. Each automatic sprinkler system shall have a single, approved device to be installed on the exterior of the building on the address side of the building, or in an alternative location as approved by the Fire Code Official; additional devices may be required at the discretion of the Fire Code Official. This device shall be a weatherproof horn/strobe notification appliance with a minimum 75 candela strode rating. Installations intended to comply with this section shall have a single audible/visual notification appliance to be located in an approved, normally occupied location, within each occupancy group of a building. Incidental uses shall not require an additional notification device. Additional notification devices not mentioned in this section shall not be allowed. 63. The amendment of Section 903.4.2, entitled Alarms, by adding Section 903.4.2.1, entitled Waterflow alarm initiation, which shall read as follows: 903.4.2.1 Waterflow alarm initiation. Any waterflow-type of detector device required by this code on all sprinkler or standpipe systems shall cause an alarm upon the detection of waterflow between 45 and 90 seconds. All alarms caused by the initiation of waterflow shall be programmed to be audible and shall continue to report as such until the flow of water has been disrupted. 64. The amendment of Section 903.4.3, entitled Floor control valves, to read as follows: 903.4.3 Floor control valves. When a standpipe system is installed or required to be installed in a building, a separate indicating floor control valve shall be installed for each connection to an express main or supply feed to each floor throughout the building. A separate control valve shall be provided for each floor that is served by a standpipe system or protected by an automatic sprinkler system and shall be supervised by the building’s fire alarm system. Each floor control valve shall also be accompanied by a waterflow switch which shall comply with Section 903.4.2.1. 65. The amendment of Section 903, entitled AUTOMATIC SPRINKLER SYSTEMS, by adding Section 903.6, entitled Spray booths and rooms, which shall read as follows: 903.6 Spray booths and rooms. New and existing spray booths and spray rooms shall be protected by an approved automatic fire extinguishing system in accordance with Section 2404.4 of the International Fire Code. 66. The amendment of Section 904.4.2.1, entitled Audible and visible signals, to read as follows: 904.4.2.1 Audible and visible signals. All systems installed in accordance with Section 904 that are not otherwise required to be interconnected to the building’s fire alarm system shall be provided with a single approved audible (local) notification appliance or method to announce the activation of such system. The audibility of all required notification appliances shall be verified. 67. The amendment of Section 905.2, entitled Installation standard, to read as follows: 905.2 Installation standard. Standpipe systems shall be installed in accordance with this section and NFPA 14. Manual dry standpipe systems shall be supervised with a minimum of 10 psig and a maximum of 40 psig air pressure with a high/low alarm and shall be designed with the following hydraulic factors: Static – 175psi, Residual – 174psi, Flow – 1500gpm. Fire department connections for standpipe systems shall be in accordance with Section 912. 68. The amendment of Section 905.3.2, entitled Group A, by deleting Exceptions #1 and #2. 69. The amendment of Section 905.3, entitled Required installations, by adding Section 905.3.9, entitled Buildings exceeding 10,000 sq. ft., which shall read as follows: 905.3.9 Buildings Exceeding 10,000 sq. ft. In buildings exceeding 10,000 square feet in area per story and where any portion of the building’s interior area is more than 200 feet (60960 mm) of travel, vertically and horizontally, from the nearest point of fire department vehicle access, Class I automatic wet or manual wet standpipes shall be provided. Exceptions: 1. Automatic dry, semi-automatic dry, and manual dry standpipes are allowed as provided for in NFPA 14 where approved by the fire code official. 2. R-2 occupancies of four stories or less in height having no interior corridors. 70. The amendment of Section 905.4, entitled Location of Class I standpipe hose connections, by amending Items 1, 3, and 5, and adding Item 7, all of which shall read as follows: 1. In every required exit stairway, a hose connection shall be provided for each story above and below grade plane. Hose connections shall be located at an intermediate landing between stories, unless otherwise approved by the fire code official. Exception: A single hose connection shall be permitted to be installed in the open corridor or open breezeway between open stairs that are not greater than 75 feet (22 860 mm) apart. 3. In every exit passageway, at the entrance from the exit passageway to other areas of a building. Exception: Where floor areas adjacent to an exit passageway are reachable from an exit stairway hose connection by a 30-foot (9144 mm) hose stream from a nozzle attached to 100 feet (30 480mm) of hose, a hose connection shall not be required at the entrance from the exit passageway to other areas of the building. 5. Where the roof has a slope less than 4 units vertical in 12 units horizontal (33.3-percent slope), each standpipe provided with a two-way a hose connection shall be located to serve the roof or at the highest landing of an exit stairway with stair access to the roof provided in accordance with Section 1011.12. 7. When required by this Chapter, standpipe connections shall be placed adjacent to all required exits to the structure and at 200 feet (60 960 mm) intervals along major corridors thereafter, or as otherwise approved by the fire code official. 71. The amendment of Section 905.8, entitled Dry standpipes, to read as follows: 905.8 Dry standpipes. Dry standpipes shall not be installed. Exception: Where subject to freezing and in accordance with NFPA 14. Additionally, manual dry standpipe systems shall be supervised with a minimum of 10 psig and a maximum of 40 psig air pressure with a high/low Supervisory alarm. 72. The amendment of Section 905.9, entitled Valve supervision, by adding a second paragraph after the exceptions, which shall read as follows: Sprinkler and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for more than 45 seconds. All control valves in the sprinkler and standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a supervisory signal at the central station upon tampering. 73. The amendment of Section 906.1, entitled Where required, Subsection 1, by deleting Exception 3, 3.1-3.5, in its entirety. 74. The amendment of Section 907.1.2, entitled Fire alarm shop drawings, by adding the following subsections, which shall read as follows: 907.1.2.1 The type, location, power supply detail, and interconnectivity of single- or multiple- station smoke alarms. 907.1.2.2 The type, location, power supply detail, and interconnectivity of single- or multiple- station carbon monoxide alarms. 75. The amendment of Section 907.1.3, entitled Equipment, by adding the following subsections, which shall read as follows: 907.1.3.1 Fire alarm control panel. The fire alarm control panel shall be installed in an approved location adjacent to the main entrance to the building unless otherwise approved by the Fire Code Official. In such instances, an annunciator shall be installed at the main entrance. 907.1.3.2 Key/Codes. Fire alarm control panel functions such as "silence" and "reset" shall be operable without the use of a key or code. The panel cover may be locked, but a key to unlock it shall be located in a key box, in accordance with Section 506. 76. The amendment of Section 907.1, entitled General., by adding Section 907.1.4, entitled Design standards, which shall read as follows: 907.1.4 Design standards. Fire alarm systems, emergency voice alarm communication systems and their appurtenances shall be designed, installed and maintained in accordance with NFPA 72. All newly installed systems, including those which are installed to replace existing systems and those that are installed to comply with Section 903.4 through 903.4.2, shall be of the addressable type. Fire alarm systems serving more than seventy-five (75) detector-type initiating devices or more than 200 total devices, shall be analog intelligent addressable fire detection systems. Exception: Existing systems need not comply unless the total system alterations exceed 30% of the original system design or when the building has undergone more than 50% alteration initiated after October 1st, 1998. Timeframes to comply shall be determined by the Fire Code Official. 77. The amendment of Section 907.2.1, entitled Group A, to read as follows: 907.2.1 Group A. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group A occupancies having an occupant load of 300 or more persons, or where the occupant load is more than 100 persons above or below the lowest level of exit discharge. Group A occupancies not separated from one another in accordance with Section 707.3.10 of the International Building Code shall be considered as a single occupancy for the purposes of applying this section. Portions of Group E occupancies occupied for assembly purposes shall be provided with a fire alarm system as required for the Group E occupancy. Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 and the occupant notification appliances will activate throughout the notification zones upon sprinkler water flow. Activation of fire alarm notification appliances shall: 1. Cause illumination of the means of egress with light of not less than 1 foot-candle (11 lux) at the walking surface level, and 2. Stop any conflicting or confusing sounds and visual distractions. 78. The amendment of Section 907.2.3, entitled Group E., to read as follows: 907.2.3 Group E. A manual fire alarm system that initiates that occupant notification signal utilizing an emergency voice/alarm communication system meeting the requirements of Section 907.5.2.2 and installed in accordance with Section 907.6 shall be installed in Group E educational occupancies. When automatic sprinkler systems or smoke detectors are installed, such systems or detectors shall be connected to the building fire alarm system. An approved fire alarm system shall be installed in Group E day care occupancies. Unless separated by a minimum of 100 ft. open space, all buildings, whether portable or permanent buildings, will be considered one building for alarm occupant load consideration and interconnection of alarm systems. Exceptions: 1. Portable/Temporary buildings in Group E Educational occupancies with manual fire alarm systems are not required to be connected to the alarm system in the main building. 2. Residential in-home day care with not more than 12 children may use interconnected single station detectors in all habitable rooms. (For care of more than five children 2½ or less years of age, see Section 907.2.6.) 79. The amendment of Section 907.2.7, entitled Group M, by deleting Section 907.2.7.1, entitled Occupant notification, in its entirety. 80. The amendment of section 907.2.10, entitled Group S, to read as follows: 907.2.10 Group S. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group S public- and self-storage occupancies for interior corridors and interior common areas. Visible notification appliances are not required within storage units. Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1, and the occupant notification appliances will activate throughout the notification zones upon sprinkler water flow. 81. The amendment of Section 907.2.13, entitled High-rise buildings, Exception 3, to read as follows: 3. Buildings with an occupancy in Group A-5 in accordance with Section 303.1 of the International Building Code, when used for open air seating; however, this exception does not apply to accessory uses, including but not limited to, sky boxes, restaurants and similarly enclosed areas. 82. The amendment of Section 907.4.2, entitled Manual fire alarm boxes, by adding Section 907.4.2.7, entitled Type, which shall read as follows: 907.4.2.7 Type. Manual alarm initiating devices shall be an approved double action type. 83. The amendment of Section 907.5.2.3, entitled Visible alarms, by amending Exception 1 to read as follows: 1. The Fire Code Official shall determine if visible alarm notification appliances are required in alterations. 84. The amendment of Section 907.6.1, entitled Wiring, by adding Section 907.6.1.1, entitled Installation, which shall read as follows: 907.6.1.1 Installation. All fire alarm systems shall be installed in such a manner that a failure of any single initiating device or single open in an initiating circuit conductor will not interfere with the normal operation of other such devices. All signaling line circuits (SLC) shall be installed in such a way that a single open will not interfere with the operation of any addressable devices. Outgoing and return SLC conductors shall be installed in accordance with NFPA 72 requirements for Class A, Style 6 circuits and shall have a minimum of six horizontal feet separation and a minimum of one-foot vertical separation between supply and return circuit conductors. The initiating device circuit (IDC) from a signaling line circuit interface device may be wired Class B, provided the distance from the interface device to the initiating device is ten feet or less. 85. The amendment of Section 907.6.3, entitled Initiating device identification, by deleting all Exceptions in their entirety. 86. The amendment of Section 907.6.6, entitled Monitoring, by adding a second sentence to the section before the Exceptions which shall read as follows: See Section 907.6.3 for the required information transmitted to the supervising station. 87. The Section 907.6.6., entitled Monitoring, by adding Section 907.6.6.4, entitled Local alarm system, which shall read as follows: 907.6.6.4 Local alarm system. When an automatic fire alarm system is not monitored by an approved central station alarm company, an external weatherproof, audible/visual alarm sounding device shall be provided in an approved location with an approved sign, with a minimum of four-inch (4") letters, reading "WHEN ALARM SOUNDS, CALL FIRE DEPARTMENT" adjacent to the alarm-sounding device. An approved permanent sign reading "LOCAL ALARM ONLY – CALL 9-1-1" shall be provided on or adjacent to the fire alarm control panel and all manual fire alarm pull stations. 88. The amendment of Section 910.2, entitled Where required., to read as follows: 910.2 Where required. Smoke and heat vents or a mechanical smoke removal system shall be installed as required by Sections 910.2.1, 910.2.2, and 910.3.2. Exceptions: 1. Frozen food warehouses used solely for storage of Class I and II commodities where protected by an approved automatic sprinkler system. 2. Only manual smoke and heat removal shall not be required in areas of buildings equipped with early suppression fast-response (ESFR) sprinklers. Automatic smoke and heat removal is prohibited. 3. Only manual smoke and heat removal shall not be required in areas of buildings equipped with control mode special application sprinklers with a response time index of 50(m*S)1/2 or less that are listed to control a fire in stored commodities with 12 or fewer sprinklers. Automatic smoke and heat removal is prohibited. 89. The amendment of Section 910.2, entitled Where required, by adding Section 910.2.3, entitled Group H, which shall read as follows: 910.2.3 Group H. Buildings and portions thereof used as a Group H occupancy as follows: 1. In occupancies classified as Group H-2 or H-3, any of which are more than 15,000 square feet (1394 m2) in single floor area. Exception: Buildings of noncombustible construction containing only noncombustible materials. 2. In areas of buildings in Group H used for storing Class 2, 3, and 4 liquid and solid oxidizers, Class 1 and unclassified detonable organic peroxides, Class 3 and 4 unstable (reactive) materials, or Class 2 or 3 water-reactive materials as required for a high-hazard commodity classification. Exception: Buildings of noncombustible construction containing only noncombustible materials. 90. The amendment of Section 910.3.4, entitled Vent operations, to read as follows: 910.3.4 Vent operations. Smoke and heat vents shall be capable of being operated by approved automatic and manual means, unless automatic operation is not allowed by Section 910.2. Automatic operation of smoke and heat vents shall conform to the provisions of Sections 910.3.4.1 and 910.3.4.2. 91. The amendment of Section 910.3.4, entitled Vent operations, by adding Section 910.3.4.1, entitled Sprinklered buildings, and Section 910.3.4.2, entitled Non-sprinklered buildings, which shall read as follows: 910.3.4.1 Sprinklered buildings. Where installed in buildings equipped with an approved automatic sprinkler system, smoke and heat vents shall be designed to operate automatically. The automatic operating mechanism of the smoke and heat vents shall operate at a temperature rating at least 100 degrees F (approximately 38 degrees Celsius) greater than the temperature rating of the sprinklers installed. Exception: Manual only systems per Section 910.2. 910.3.4.2 Non-sprinklered buildings. Where installed in buildings not equipped with an approved automatic sprinkler system, smoke and heat vents shall operate automatically by actuation of a heat-responsive device rated at between 100°F (56°C) and 220°F (122°C) above ambient. Exception: Listed gravity-operated drop out vents. 92. The amendment of Section 910.4.3.1, entitled Makeup air, to read as follows: 910.4.3.1 Makeup air. Makeup air openings shall be provided within 6 feet (1829 mm) of the floor level. Operation of makeup air openings shall be automatic. The minimum gross area of makeup air inlets shall be 8 square feet per 1,000 cubic feet per minute (0.74 m2 per 0.4719 m3/s) of smoke exhaust. 93. The amendment of Section 910.4.4, entitled Activation, to read as follows: 910.4.4 Activation. The mechanical smoke removal system shall be activated only automatically by the automatic sprinkler system or by an approved fire detection system. Individual manual controls shall also be provided. Exception: Manual only systems per Section 910.2. 94. The amendment of Section 912.2, entitled Location, to read as follows: 912.2 Location. The location of all fire department connections shall be approved by the Fire Code Official. Fire department connections shall be located so that fire apparatus staging and hose connected to the fire department connection will not obstruct access to the building for other fire apparatus. Fire department connection location shall account for obstructions from driveways, buildings, security barriers, fences, and landscaping. Each automatic sprinkler system shall be equipped with at least one fire department connection. If more than one building is served by a common underground fire main, each building shall have a separate fire department connection. If more than one fire department connection is provided for a common underground fire main or if more than one connection is installed for a building or buildings, the failure of one connection shall not inhibit the usage or operation of other connections, nor shall other buildings be affected by the failure of any single connection. 95. The amendment of Section 912.2, entitled Location, by adding Section 912.2.3, entitled Hydrant distance, which shall read as follows: 912.2.3 Hydrant distance. An approved fire hydrant shall be located within 100 feet of the fire department connection as the fire hose lays along an unobstructed path. 96. The amendment of Section 912.2, entitled Location, by adding Section 912.2.4, entitled High-rise buildings, to read as follows: 912.2.4 High-rise buildings. All fire department connections for any high-rise building shall be installed within twenty-five feet (25’) of an approved street or Fire Lane. 97. The amendment of Section 912.3, entitled Fire hose threads, to read as follows: 912.3 Fire hose threads. All fire department connections within the jurisdiction shall be a 4-inch Storz-type connection. This connection shall be constructed of high-strength, lightweight, corrosion-resistant aluminum alloy capable of being securely attached to the outlets/piping and shall conform to applicable industry standards in regards to design and installation. The hose sealing surface shall consist of a machined metal seat to eliminate rubber gaskets, coated to protect against long term exposure to the environment. The Storz connection shall connect to the pipe outlet using National Standard Thread. The connection shall be angled downward at a 30º angle. An approved locking device shall be installed on each fire department connection. 98. The amendment of Section 913.2.1, entitled Protection of fire pump rooms, by adding Section 913.2.1.1, entitled Fire Pump Room Access, and an exception, which shall read as follows: 913.2.1.1 Fire Pump Room Access. When located on the ground level at an exterior wall, the fire pump room shall be provided with an exterior fire department access door that is not less than 3 ft. in width and 6 ft. – 8 in. in height, regardless of any interior doors that are provided. A key box shall be provided at this door, as required by IFC Section 506.1. Exception: When it is necessary to locate the fire pump room on other levels or not at an exterior wall, the corridor leading to the fire pump room access from the exterior of the building shall be provided with equivalent fire resistance as that required for the pump room, or as approved by the fire code official. Access keys shall be provided in the key box as required by IFC Section 506.1. 99. The amendment of Section 913.4, entitled Valve supervision, to read as follows: 913.4 Valve supervision. Where provided, fire pump suction, discharge, and bypass valves, and isolation valves on the backflow prevention device or assembly shall be supervised in accordance with Section 903.4 – as amended. 100. The amendment of Section 915.1.1, entitled Where required, by adding a second paragraph which shall read as follows: Carbon monoxide detection shall be installed for commercial kitchen hoods complying with NFPA 96, in accordance with Section 915.2.4. 101. The amendment of Section 915.2.3, entitled Group E occupancies, to read as follows: 915.2.3 Group E occupancies. Carbon monoxide detection shall be installed in classrooms and other required locations, as determined by the Fire Code Official, in Group E occupancies and shall be tied into the building’s fire alarm system in accordance with NFPA 72. Carbon monoxide alarms shall be automatically transmitted to an on-site location that is staffed by school personnel and shall annunciate at the fire alarm control unit as a non-silenceable, latching alarm with a distinct audible and visual alarm. 102. The amendment of Section 915.4, entitled Carbon monoxide alarms, by adding Section 915.4.5, entitled Commercial kitchen hoods, which shall read as follows: 915.4.5 Commercial kitchen hoods. Carbon monoxide detection shall be installed in commercial kitchens with new or remodeled hoods complying with Section 606.2 and NFPA 96. Carbon monoxide detectors shall be installed in an approved location in the kitchen relatively near the fuel-fired gas appliances and in an approved location in the dining area, if applicable. Carbon monoxide detectors shall be interconnected to the fire alarm system and shall report distinctively as such, in accordance with NFPA 72. Standalone detectors shall be allowed if the building is not equipped with a fire alarm system; in this instance, local audible notification from the detector(s) is required. 103. The amendment of Section 1006.2.1, entitled Egress based on occupant load and common path of egress travel distance, by amending Exception 3 to read as follows: 3. Unoccupied rooftop mechanical rooms and penthouses are not required to comply with the common path of egress travel distance measurement. 104. The amendment of Section 1009.1, entitled Accessible means of egress required, by adding Exception 3, which shall read as follows: 3. Projects registered with the Architectural Barriers Division of the Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of Section 1009. 105. The amendment of Section 1009.8, entitled Two way communication, by adding Exception 7, which shall read as follows: 7. Buildings regulated under state law and built in accordance with state registered plans, including variances or waivers granted by the State of Texas, shall be deemed to comply with the requirements of Section 1009 (Accessible Means of Egress) and Chapter 11 (Accessibility). 106. The amendment of Section 1010.2.5, entitled Bolt locks, by amending Exceptions 3 and 4 to read as follows: 3. Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F, M or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf. The inactive leaf shall not contain doorknobs, panic bars, or similar operating hardware. 4. Where a pair of doors serves a Group A, B, F, M or S occupancy, manually operated edge- or surface-mounted bolts are permitted on the inactive leaf, provided that such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The inactive leaf shall not contain doorknobs, panic bars, or similar operating hardware. 107. The amendment of Section 1010.2.7, entitled Stairway doors, by adding Exception 6, which shall read as follows: 6. In stairways serving more than four stories, doors can be locked from stairway side if lock is connected to fire alarm system and key to the door is provided in a Knox Box. Activation of fire alarm system must release locks on all stairway doors. 108. The amendment of Section 1017.3, entitled Measurement, by adding Exceptions 3 and 4, which shall read as follows: 3. In other than occupancy Groups H and I, the exit access travel distance to a maximum of 50 percent of the exits is to be measured from the most remote point within a building to an exit using unenclosed exit access stairways or ramps when connecting to a maximum of two stories. The two connected stories shall be provided with at least two means of egress. Such interconnected stories shall not be open to other stories. 4. In other than occupancy Groups H and I, the exit access travel distance to a maximum of 50 percent of the exits is to be measured from the most remote point within a building to an exit using unenclosed exit access stairways or ramps in the first and second stories above grade plane in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The first and second stories above grade plane shall be provided with at least two means of egress. Such interconnected stories shall not be open to other stories. 109. The amendment of Section 1017, entitled EXIT ACCESS TRAVEL DISTANCE, by adding Section 1017.4, entitled Roof Vent Increase, which shall read as follows: 1017.4 Roof Vent Increase. In buildings that are one story in height, equipped with automatic heat and smoke roof vents complying with Section 910 and equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the maximum exit access travel distance shall be 400 feet for Group F-1 or S-1 occupancies. 110. The amendment of Section 1020.2, entitled Construction, by adding Exception 6, which shall read as follows: 6. In unsprinklered group B occupancies, corridor walls and ceilings need not be of fire-resistive construction within a single tenant space when the space is equipped with approved automatic smoke-detection within the corridor. The actuation of any detector must activate self-annunciating alarms audible in all areas within the corridor. Smoke detectors must be connected to an approved automatic fire alarm system where such system is provided. 111. The amendment of Section 1030.1.1.1, entitled Spaces under grandstands and bleachers, by adding Exception 4, which shall read as follows: 4. Where alternate means or methods are submitted to and approved by the Building and Fire Officials. 112. The amendment of Section 1101.1, entitled Scope, by adding an Exception, which shall read as follows: Exception: Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of this chapter. 113. The amendment of Section 1612.3, entitled Establishment of flood hazard areas., to read as follows: 1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the applicable governing authority shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled "The Flood Insurance Study for Tarrant County, Texas", dated September 25, 2009, as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. 114. The amendment of Section 1612.3.2, entitled Determination of impacts, to read as follows: 1612.3.2 Determination of impacts. In flood hazard areas where design flood elevations are specified, the applicant shall provide an engineering analysis developed by a licensed professional engineer that demonstrates that the proposed work will not increase the design flood elevation or reduce conveyance at any point within the jurisdiction in accordance with the provisions of the Design Criteria Manual and the Flood Damage Prevention Chapter of the Arlington City Code. 115. The amendment of Section 1612.2, entitled Design and construction, to read as follows: 1612.2 Design and construction. The design and construction of buildings and structures located in flood hazard areas, including flood hazard areas subject to high-velocity wave action, shall be in accordance with Chapter 5 of ASCE 7 and with ASCE 24 and provisions of the City of Arlington’s Flood Damage Prevention Chapter. 116. The amendment of Section 1612.4, entitled Flood hazard documentation, to read as follows: 1612.4 Flood hazard documentation. The flood hazard documentation as identified in the City of Arlington’s Flood Damage Chapter shall be prepared and sealed by a professional engineer and submitted to the building official. 117. The amendment of Section 1704.2, entitled Special inspections and tests, to read as follows: 1704.2 Special inspections and tests. Where application is made to the Building Official for construction as specified in Section 105, the owner or the owner’s authorized agent, or the registered design professional in responsible charge, other than the contractor, shall employ one or more approved agencies to provide special inspections and tests during construction on the types of work listed under Section 1705 and identify the approved agencies to the Building Official. The special inspector shall not be employed by the contractor. These special inspections and tests are in addition to the inspections identified by the Building Official that are identified in Section 110. 118. The amendment of Section 1704.2.1, entitled Special inspector qualifications, is amended to read as follows: 1704.2.1 Special inspector qualifications. Prior to the start of construction and or upon request, the approved agencies shall provide written documentation to the registered design professional in responsible charge and the building official demonstrating the competence and relevant experience or training of the special inspectors who will perform the special inspections and tests during construction. Experience or training shall be considered to be relevant where the documented experience or training is related in complexity to the same type of special inspection or testing activities for projects of similar complexity and material qualities. These qualifications are in addition to qualifications specified in other sections of this code. The registered design professional in responsible charge and engineers of record involved in the design of the project are permitted to act as an approved agency and their personnel are permitted to act as special inspectors for the work designed by them, provided they qualify as special inspectors. 119. The amendment of Section 1704.2.4, entitled Report requirement, is amended to read as follows: 1704.2.4 Report requirement. Approved agencies shall keep records of special inspections and tests. The approved agency shall submit reports of special inspections and tests to the Building Official upon request, and to the registered design professional in responsible charge. Individual inspection reports shall indicate that work inspected or tested was or was not completed in conformance to approved construction documents. Discrepancies shall be brought to the immediate attention of the contractor for correction. If they are not corrected, the discrepancies shall be brought to the attention of the building official and to the registered design professional in responsible charge prior to the completion of that phase of the work. A final report documenting required special inspections and tests, shall be submitted at a point in time agreed upon prior to the start of work by the owner or the owner’s authorized agent to the building official. 120. The amendment of Section 1704.2.5.1, entitled Fabricator approval, to read as follows: 1704.2.5.1 Fabricator approval. Special inspections during fabrications required by Section 1704 are not required where the work is done on the premises of a fabricator registered and approved to perform such work without special inspection. Approval shall be based upon review of the fabricator's written procedural and quality control manuals and periodic auditing of fabrication practices by an approved agency, or a fabricator that is enrolled in a nationally accepted inspections program. At completion of fabrication, the acceptable or approved fabricator shall submit a certificate of compliance to the owner or the owner’s authorized agent or the registered design professional in responsible charge, for submittal to the building official as specified in Section 1704.5 stating that the work was performed in accordance with the approved construction documents. The certificate of compliance shall also be made available to the Building Official upon request. 121. The amendment of Section 1807.2, entitled Retaining walls., to read as follows: 1807.2 Retaining walls. Retaining walls exceeding four feet (4′) in developed height (the height from the base of the foundation to the top of the wall) at any point shall be designed by a professional engineer. A wall built in tiers shall be considered a single wall in developed height when the base of the upper tier is set back from the base of the lower tier less than one and one-half (1½) times the developed height of the wall section below. Walls supporting an imposed load such as a building, driveway or other permanent construction closer to the wall than one and one-half (1½) times the developed height of the wall shall be designed by a professional engineer. When required to be designed by an engineer the design shall be in accordance with Sections 1807.2.1 through 1807.2.3. 122. The amendment of Section 1809.5.1, entitled Frost Protection at required exits, by deleting the section in its entirety. 123. The amendment of Section 2702, entitled EMERGENCY AND STANDBY POWER SYSTEMS, by adding Section 2702.5, entitled Designated Critical Operations Areas (DCOA), which shall read as follows: Section 2702.5 Designated Critical Operations Areas (DCOA) In areas within a facility or site requiring continuous operation for the purpose of public safety, emergency management, national security or business continuity, the power systems shall comply with NFPA 70 Article 708. 124. The amendment of Section 2901.1, entitled Scope, by adding the following sentence, which shall read as follows: The provisions of this Chapter are meant to work in coordination with the provisions of Chapter 4 of the International Plumbing Code. Should any conflicts arise between the two chapters, the Building Official shall determine which provision applies. 125. The amendment of Section 2902.1, entitled Minimum number of fixtures, by adding a second paragraph which shall read as follows: In other than E Occupancies, the minimum number of fixtures in Table 2902.1 may be lowered, if requested in writing, by the applicant stating reasons for a reduced number and approved by the Building Official. 126. The amendment of Table 2902.1, entitled MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES, by adding footnote g, which shall read as follows: g. Drinking fountains are not required in M Occupancies with an occupant load of 100 or less, B Occupancies with an occupant load of 25 or less, and for dining and/or drinking establishments. 127. The amendment of Section 2902.1, entitled Minimum number of fixtures, by adding Section 2902.1.4, et seq, which shall read as follows: 2902.1.4 Additional fixtures for food preparation facilities. In addition to the fixtures required in this Chapter, all food service facilities shall be provided with additional fixtures set out in this section. 2902.1.4.1 Hand washing lavatory. At least one hand washing lavatory shall be provided for use by employees that is accessible from food preparation, food dispensing and ware washing areas. Additional hand washing lavatories may be required based on convenience of use by employees. 2902.1.4.2 Service sink. In new or remodeled food service establishments, at least one service sink or one floor sink shall be provided so that it is conveniently located for the cleaning of mops or similar wet floor cleaning tool and for the disposal of mop water and similar liquid waste. The location of the service sink(s) and/or mop sink(s) shall be approved by the City of Arlington health department. 128. The amendment of Section 2902.2, entitled Separate facilities, by deleting Exception 6 in its entirety. 129. The amendment of Section 3002.1, entitled Hoistway enclosure protection, by adding the following Exceptions: Exceptions: 1. Elevators completely located within atriums shall not require hoistway enclosure protection. 2. Elevators in open or enclosed parking garages that serve only the parking garage, shall not require hoistway enclosure protection. 130. The amendment of Section 3005.4, entitled Machine rooms, control rooms, machinery spaces and control spaces, by deleting the 2 existing exceptions and replacing them with the following: Exceptions: 1. Elevator machine rooms, control rooms, machinery spaces and control spaces completely located within atriums shall not require enclosure protection. 2. Elevator machine rooms, control rooms, machinery spaces and control spaces in open or enclosed parking garages that serve only the parking garage, shall not require enclosure protection. 131. The amendment of Section 3005.5, entitled Shunt trip, by adding Section 3005.5.1, et seq., which shall read as follows: 3005.5.1 Fire Protection in Machine rooms, control rooms, machinery spaces and control spaces. 3005.5.1.1 Automatic sprinkler system. The building shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, except as otherwise permitted by Section 903.3.1.1.1 and as prohibited by Section 3005.5.1.1.1. 3005.5.1.1.1 Prohibited locations. Automatic sprinklers shall not be installed in machine rooms, elevator machinery spaces, control rooms, control spaces and elevator hoistways. 3005.5.1.1.2 Sprinkler system monitoring. The sprinkler system shall have a sprinkler control valve supervisory switch and water-flow initiating device provided for each floor that is monitored by the building’s fire alarm system. 3005.5.1.2 Water protection. An approved method to prevent water from infiltrating into the hoistway enclosure from the operation of the automatic sprinkler system outside the elevator lobby shall be provided. 3005.5.1.3 Omission of Shunt trip. Means for elevator shutdown in accordance with Section 3005.5 shall not be installed. 132. The amendment of Section 3005, entitled MACHINE ROOMS, by adding Section 3005.7, entitled Storage, which shall read as follows: 3005.7 Storage. Storage shall not be allowed within the elevator machine room, control room, machinery spaces and or control spaces. Provide approved signage at each entry to the above listed locations stating: "No Storage Allowed". 133. The amendment of Section 3006.2, Hoistway opening protection required, by replacing Condition 5 with the following: 5. The building is a high rise and the elevator hoistway is more than 75 feet (22 860 mm) in height. The height of the hoistway shall be measured from the lowest floor at or above grade to the highest floors served by the hoistway." 134. The amendment of Section 3007.3, entitled Water protection, to read as follows: 3007.3 Water Protection. Water from the operation of an automatic sprinkler system outside the lobby shall be prevented from infiltrating into the hoistway enclosure in accordance with an approved method. 135. The amendment of Section 3008.3, entitled Water protection, to read as follows: 3008.3 Water Protection. Water from the operation of an automatic sprinkler system outside the lobby shall be prevented from infiltrating into the hoistway enclosure in accordance with an approved method. D. The following local amendments to the International Residential Code (I.R.C.) are hereby adopted: 1. The amendment of Section R101.1, entitled Title, to read as follows: R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-family Dwellings of the City of Arlington, Texas, and shall be cited as such and will be referred to herein as "this code." 2. The amendment of Section R102.4, entitled Referenced codes and standards, to read as follows: R102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standards shall be considered to reference the amendments as well. Any reference made to NFPA 70, or ICC Electrical Code shall mean the Electrical Code as adopted. Where differences occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply. Exception: Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and manufacturer's instructions shall apply. 3. The amendment of Section R104.10.1, entitled Flood hazard areas, by deleting the section in its entirety. 4. The deletion of Section R105, entitled PERMITS, in its entirety. 5. The deletion of Section R106, entitled CONSTRUCTION DOCUMENTS, in its entirety. 6. The deletion of Section R108, entitled FEES, in its entirety. 7. The deletion of Section R109, entitled INSPECTIONS, in its entirety. 8. The deletion of Section R110, entitled CERTIFICATE OF OCCUPANCY, in its entirety. 9. The deletion of Section R112, entitled BOARD OF APPEALS, in its entirety. 10. The deletion of Section R113, entitled VIOLATIONS, in its entirety. 11. The amendment of Section R114, entitled STOP WORK ORDER, to read as follows: SECTION R114 STOP WORK ORDER R114.1 Stop Work Order. Whenever any work is being done contrary to the provisions of this Code, the Building Official may order the work stopped by notice in writing served on any persons engaged in the doing or causing such work to be done. Any such person shall forthwith stop such work until: a. He or she is authorized by the Building Official to proceed with the work; or b. An appeal perfected pursuant to Section 2.06 of Article II has resulted in a waiver of the condition causing the stop order, or a finding that there is no cause for a stop order. Failure to stop such work, in addition to penalties and remedies elsewhere set forth, shall void any appeal. 12. The amendment of Section R202, entitled DEFINITIONS, by amending the definition of TOWNHOUSE UNIT to read as follows: TOWNHOUSE UNIT. A single-family dwelling unit separated by property lines in a townhouse that extends from foundation to roof and that has a yard or public way on not less than two sides. 13. The amendment of Table R301.2, entitled CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA, by filling in the local criteria as follows: (MPH) g Line ICE BARRIER UNDER- AIR FREEZING INDEXi WIND DESIGN SEISMIC SUBJECT TO DESIGN DAMAGE FROM GROUND A a Depthb WINTER DESIGN CATEGOR MEAN ANNUAL Windborne Debris Zonem SPEEDd Yf Weatherin Frost Termitec Special Wind RegionL FLOOD TEMPj LAYMENT h HAZARDSg SNOW LOAD TEMPe Topographic Effectsk 5 lb/ft 115 220 F No Local 150 64.90 F (3 sec- No No No Moderate 6" Very Code gust)/ 76 Heavy fastest mile {Delete remainder of table Manual J Design Criteria and footnote N} 14. The amendment of Section R302.1, entitled Exterior walls, by adding Exception 6, which shall read as follows: 6. Open non-combustible carport structures may be constructed when also approved within adopted ordinances. 15. The amendment of Section R302.2.6, entitled Structural independence, by deleting Exception 6 in its entirety. 16. The amendment of Section R302.3, entitled Two-family dwellings, by adding Exception 3, which shall read as follows: 3. Two-family dwelling units that are also divided by a property line through the structure shall be separated as required for townhouses. 17. The amendment of Section R302.5.1, entitled Opening protection, to read as follows: R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. 18. The amendment of Section R303.3, entitled Bathrooms, by amending the Exception to add the following sentence: Spaces containing only a water closet or water closet and a lavatory may be ventilated with an approved mechanical recirculating fan or similar device designed to remove odors from the air. 19. The amendment of Section R307, entitled TOILET, BATH AND SHOWER SPACES, by adding R307.3, entitled Blocking, which shall read as follows: R307.3 Blocking. Required at one toilet at grade level. Blocking per Sec. R307.4 and Figure 307.4, shall be installed at rear wall and one wall adjacent to toilet at the lowest living level where a toilet is provided. 20. The amendment of Section R307, entitled TOILET, BATH AND SHOWER SPACES, by adding R307.4, entitled Blocking R307.4 Blocking. Blocking may be ½" plywood or equivalent or 2 x solid wood blocking flush with wall. [image omitted; see the official code] 21. The amendment of Section R313.2, entitled One- and two-family dwellings automatic sprinkler systems, by deleting the section in its entirety. 22. The amendment of Section R315.2.2, entitled Alterations, repairs and additions, by amending Exception 2 to read as follows: 2. Installation, alteration or repairs of all electrically powered mechanical systems or plumbing appliances. 23. The amendment of Section R322, entitled FLOOD RESISTANT CONSTRUCTION, by deleting the section in its entirety. 24. The amendment of Section R327, entitled SWIMMING POOLS, SPAS AND HOT TUBS, Section R327.1, entitled General, by adding Section R327.1.1, entitled Adjacency to Structural Foundation, which shall read as follows: R327.1.1 Adjacency to Structural Foundation. Depth of the swimming pool and spa shall maintain a ratio of 1:1 from the nearest building foundation or footing of a retaining wall. Exception: A sealed engineered design drawing of the proposed new structure shall be submitted for approval. 25. The amendment of Section R401.2, entitled Requirements, by adding a second and third paragraph which shall read as follows: Every foundation and/or footing, or any size addition to an existing post-tension foundation, regulated by this code shall be designed and sealed by a Texas-registered engineer. Foundations for the construction of new 1- and 2-family homes and foundations for additions to existing 1- and 2-family homes shall be designed by an engineer licensed by the State of Texas. 26. The amendment of Section R602.6.1, entitled Drilling and notching of top plate, by amending the first paragraph to read as follows: R602.6.1 Drilling and notching of top plate. When piping or ductwork is placed in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than 50 percent of its width, a galvanized metal tie not less than 0.054 inch thick (1.37 mm) (16 Ga) and 5 inches (127 mm) wide shall be fastened across and to the plate at each side of the opening with not less than eight 10d (0.148 inch diameter) having a minimum length of 1 ½ inches (38 mm) at each side or equivalent. Fasteners will be offset to prevent splitting of the top plate material. The metal tie must extend a minimum of 6 inches past the opening. See figure R602.6.1. 27. The amendment of Figure R602.6.1, entitled TOP PLATE FRAMING TO ACCOMMODATE PIPING, by deleting the figure and replacing same with the following figure: [image omitted; see the official code] 28. The amendment of Section R703.8.4.1, entitled Size and spacing, by adding Section R703.8.4.1.2, entitled Veneer ties for wall studs, which shall read as follows: R703.8.4.1.2 Veneer Ties for Wall Studs. In stud framed exterior walls, all ties may be anchored to studs as follows: 1. When studs are 16 in (407 mm) o.c., stud ties shall be spaced no further apart than 24 in (737 mm) vertically starting approximately 12 in (381 mm) from the foundation; or 2. When studs are 24 in (610 mm) o.c., stud ties shall be spaced no further apart than 16 in (483 mm) vertically starting approximately 8 in (254 mm) from the foundation. 29. The amendment of Section R902.1, Roof covering materials, by amending the first paragraph to read as follows: R902.1 Roofing covering materials. Roofs shall be covered with materials as set forth in Sections R904 and R905. Class A, B, or C roofing shall be installed. Class A, B and C roofing required by this section to be listed shall be tested in accordance with ASTM E108 and UL 790. 30. The amendment of Section R902.1, Roof covering materials, by adding Exception 5, which shall read as follows: 5. Non-classified roof coverings shall be permitted on one-story detached accessory structures used as tool and storage sheds, playhouses, and similar uses, provided the floor area does not exceed 120 square feet. 31. The amendment of Chapter 11, entitled [RE] Energy Efficiency, by deleting the Chapter in its entirety. Reference the 2021 IECC for energy code provisions and recommended amendments. 32. The amendment of Section M1305.1.2, entitled Appliances in attics, to read as follows: M1305.1.2 Appliances in attics. Attics containing appliances shall be provided with an opening and unobstructed passageway large enough to allow removal of the largest appliance. The passageway shall be not less than 30 inches (762 mm) high and 22 inches (559 mm) wide and not more than 20 feet (6096 mm) in length measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring not less than 24 inches (610 mm) wide. A level service space not less than 30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present at the front or service side of the appliance. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), or larger where such dimensions are not large enough to allow removal of the largest appliance. A walkway to an appliance shall be rated as a floor as approved by the building official. As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull down stair with a minimum 300 lb. (136 kg) capacity. 3. An access door from an upper floor level. 4. Access Panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due to building conditions. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. 2. Where the passageway is unobstructed and not less than 6 feet (1829 mm) high and 22 inches (559 mm) wide for its entire length, the passageway shall be not greater than 50 feet (15 250 mm) in length. 33. The amendment of Section M1411.3, entitled Condensate disposal, to read as follows: M1411.3 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to a permanently wet p-trap. Condensate shall not discharge in a publicly exposed area such as into a street, alley, sidewalk or other areas so as to cause a nuisance. Exceptions: 1. Condensate may discharge directly to a roof drain that connects to an underground storm sewer system, 2. Condensate may discharge directly onto roofs covered with membrane type roof coverings where the condensate will drain to a roof drain that connects to an underground storm sewer system, 3. Condensate may discharge to a landscaped area containing flowers and other bedding plants other than turf. There must be five square feet of landscaped area for each ton of refrigeration, or 4. Condensate may discharge to a French drain consisting of a pit excavated below grade that is not less than 24 inches (610 mm) in any dimension. The pit shall be filled with coarse gravel and the drainpipe shall extend into the pit and be securely anchored. A single drain shall not receive the condensate discharge of more than 10 tons nominal of combined cooling capacity. The pit shall be covered with sod after inspection. The French drain shall not be located so that it will receive direct discharge from a roof or a downspout. 34. The amendment of Section M1411.3.1, entitled Auxiliary and secondary systems, by amending Items 3 and 4 to read as follows: 3. An auxiliary drain pan without a separate drain line shall be installed under the coils on which condensation will occur. This pan shall be equipped with a water level detection device conforming to UL 580 that will shut off the equipment served prior to overflow of the pan. The pan shall be equipped with a fitting to allow for drainage. The auxiliary drain pan shall be constructed in accordance with Item 1 of this section. A water level detection device may be installed only with prior approval of the building official. 4. A water level detection device conforming to UL 580 shall be installed that will shut off the equipment served in the event that the primary drain is blocked. The device shall be installed in the primary drain line, the overflow drain line or the equipment-supplied drain pan, located at a point higher than the primary drain line connection and below the overflow rim of such pan. A water level detection device may be installed only with prior approval of the building official. 35. The amendment of Section M1411.3.1.1, entitled Water-level monitoring devices, to read as follows: M1411.3.1.1 Water-level monitoring devices. On down-flow units and other coils that do not have secondary drain or provisions to install a secondary or auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan. This device shall shut off the equipment served in the event that the primary drain becomes restricted. Devices shall not be installed in the drain line. A water level detection device may be installed only with prior approval of the building official. 36. The amendment of Section M1503.6, entitled Makeup air required, to read as follows: M1503.6 Makeup air required. Where one or more gas, liquid or solid fuel-burning appliance that is neither direct-vent nor uses a mechanical draft venting system is located within a dwelling unit’s air barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s) shall be mechanically or passively provided with makeup air at a rate approximately equal to the difference between exhaust air rate and 400 cubic feet per minute. Such makeup air systems shall be equipped with not fewer than one damper complying with Section M1503.6.2. Exception: Makeup air is not required for exhaust systems installed for the exclusive purpose of space cooling and intended to be operated only when windows or other air inlets are open. Where all appliances in the house are of sealed combustion, power-vent, unvented, or electric, the exhaust hood system shall be permitted to exhaust up to 600 cubic feet per minute (0.28 m3/s) without providing makeup air. Exhaust hood systems capable of exhausting in excess of 600 cubic feet per minute (0.28 m3/s) shall be provided with a makeup air at a rate approximately equal to the difference between the exhaust air rate and 600 cubic feet per minute. 37. The amendment of Section M2005.2, entitled Prohibited locations, to read as follows: M2005.2 Prohibited locations. Fuel-fired water heaters shall not be installed in a room used as a storage closet. Water heaters located in a bedroom or bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space. Access to such enclosure may be from the bedroom or bathroom when through a solid door, weather-stripped in accordance with the exterior door air leakage requirements of the International Energy Conservation Code and equipped with an approved self-closing device. Installation of direct-vent water heaters within an enclosure is not required. 38. The amendment of Section G2408.3 (305.5), entitled Private Garages, by deleting the section in its entirety. 39. The amendment of Section G2415.2 (404.2), entitled CSST, by adding a second paragraph which shall read as follows: Both ends of each section of medium pressure gas piping shall identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING: 1/2 to 5 psi gas pressure - Do Not Remove" 40. The amendment of Section G2415.12 (404.12), entitled Minimum burial depth, to read as follows: G2415.12 (404.12) Minimum burial depth. Underground piping systems shall be installed a minimum depth 18 inches (457 mm) below grade. 41. The amendment of Section G2415.12.1 (404.12.1), entitled Individual outdoor appliances, by deleting the section in its entirety. 42. The amendment of Section G2417.1 (406.1), entitled General, to read as follows: G2417.1 (406.1) General. Prior to acceptance and initial operation, all piping installations shall be inspected and pressure tested to determine that the materials, design, fabrication, and installation practices comply with the requirements of this code. The permit holder shall make the applicable tests prescribed in Sections 2417.1.1 through 2417.1.5 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the building official when the piping system is ready for testing. The equipment, material, power and labor necessary for the inspections and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. 43. The amendment of Section G2417.4 (406.4), entitled Test pressure measurement, to read as follows: G2417.4 (406.4) Test pressure measurement. Test pressure shall be measured with a monometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. 44. The amendment of Section G2417.4.1 (406.4.1), entitled Test pressure, to read as follows: G2417.4.1 (406.4.1) Test pressure. The test pressure to be used shall be no less than 3 psig (20 kPa gauge), or at the discretion of the Code Official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge. For tests requiring a pressure of 3 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one half inches (3 ½"), a set hand, 1/10 pound incrementation and pressure range not to exceed 6 psi for tests requiring a pressure of 3 psig. For tests requiring a pressure of 10 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3 ½"), a set hand, a minimum of 2/10 pound incrementation and a pressure range not to exceed 20 psi. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (1/2 psi) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Diaphragm gauges used for testing must display a current calibration and be in good working condition. The appropriate test must be applied to the diaphragm gauge used for testing. 45. The amendment of Section G2417.4.2 (406.4.2), entitled Test duration, to read as follows: G2417.4.2 (406.4.2) Test duration. The test duration shall be held for a length of time satisfactory to the Building Official, but in no case for less than fifteen (15) minutes. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa), the test duration shall be held for a length of time satisfactory to the Building Official, but in no case for less than thirty (30) minutes. 46. The amendment of Section G2420.1 (406.1), entitled General, by adding Section G2420.1.4, entitled Valves in CSST installations, which shall read as follows: G2420.1.4 Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings, and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping. 47. The amendment of Section G2420.5.1 (409.5.1), entitled Located within the same room, to read as follows: G2420.5.1 (409.5.1) Located within the same room. The shutoff valve shall be located in the same room as the appliance. The shutoff valve shall be within 6 feet (1829 mm) of the appliance, and shall be installed upstream of the union, connector or quick disconnect device it serves. Such shutoff valves shall be provided with access. Shutoff valves serving movable appliances, such as cooking appliances and clothes dryers, shall be considered to be provided with access where installed behind such appliances. Appliance shutoff valves located in the firebox of a fireplace shall be installed in accordance with the appliance manufacturer’s instructions. A secondary shutoff valve must be installed within 3 feet (914 mm) of the firebox if appliance shutoff is located in the firebox. 48. The amendment of Section G2421.1 (410.1), entitled Pressure regulators, to read as follows: G2421.1 (410.1) Pressure regulators. A line pressure regulator shall be installed where the appliance is designed to operate at a lower pressure than the supply pressure. Line gas pressure regulators shall be listed as complying with ANSI Z21.80. Access shall be protected from physical damage. Regulators installed on the exterior of the building shall be approved for outdoor installation. Access to regulators shall comply with the requirements for access to appliances as specified in Section M1305. Exception: A passageway or level service space is not required when the regulator is capable of being serviced and removed through the required attic opening. 49. The amendment of Section G2422.1.2.3 (411.1.3.3), entitled Prohibited locations and penetrations, by deleting Exception 1 and Exception 4. 50. The amendment of Section G2445.2 (621.2), entitled Prohibited use, to read as follows: G2445.2 (621.2) Prohibited use. One or more unvented room heaters shall not be used as the sole source of comfort heating in a dwelling unit. Exception: Existing approved unvented room heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the Building Official unless an unsafe condition is determined to exist as described in International Fuel Gas Code Section 108.7. 51. The amendment of Section G2448.1.1 (624.1.1), entitled Installation requirements, to read as follows: G2448.1.1 (624.1.1) Installation requirements. The requirements for water heaters relative to access, sizing, relief valves, drain pans and scald protection shall be in accordance with this code. 52. The amendment of Section P2603.3, entitled Protection against corrosion, to read as follows: P2603.3 Protection against corrosion. Metallic piping, except for cast iron, ductile iron and galvanized steel, shall not be placed in direct contact with steel framing members, concrete or cinder walls and floors or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used to prevent direct contact, the sheathing shall have a thickness of not less than 0.008 inch (8 mil) (0.203 mm) and the sheathing shall be made of approved material. Where sheathing protects piping that penetrates concrete or masonry walls or floors, the sheathing shall be installed in a manner that allows movement of the piping within the sheathing. 53. The amendment of Section P2603.5.1, entitled Sewer depth, to read as follows: P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum of 12 inches (304 mm) below finished grade at the point of septic tank connection. Building sewers shall be a minimum of 12 inches (304 mm) below grade. 54. The amendment of Section P2604, entitled TRENCHING AND BACKFILLING, by adding Section P2604.2.1, entitled Plastic sewer and DWV piping installation, which shall read as follows: P2604.2.1 Plastic sewer and DWV piping installation. Plastic sewer and DWV piping installed underground shall be installed in accordance with the manufacturer’s installation instructions. Trench width shall be controlled to not exceed the outside the pipe diameter plus 16 inches or in a trench which has a controlled width equal to the nominal diameter of the piping multiplied by 1.25 plus 12 inches. The piping shall be bedded in 4 inches of granular fill and then backfilled compacting the side fill in 6-inch layers on each side of the piping. The compaction shall be to minimum of 85 percent standard proctor density and extend to a minimum of 6 inches above the top of the pipe. 55. The amendment of Section P2801.6, entitled Required pan, to read as follows: P2801.6 Required pan. Where a storage tank-type water heater or a hot water storage tank is installed in a location where water leakage from the tank will cause damage, the tank shall be installed in a pan constructed of one of the following: 1. Galvanized steel or aluminum of not less than 0.0236 inch (0.6010 mm) in thickness. 2. Plastic not less than 0.036 inch (0.9 mm) in thickness. 3. Other approved materials. 56. The amendment of Section P2801.6.1, entitled Pan size and drain, to read as follows: P2801.6.1 Pan size and drain. The pan shall be not less than 1 1/2 inches (38 mm) in depth and shall be of sufficient size and shape to receive all dripping or condensate from the tank or water heater. The pan shall be drained by an indirect waste pipe having a diameter of not less than 3/4 inch (19 mm). Piping for safety pan drains shall be of those materials listed in Table P2906.5. Multiple pan drains may terminate to a single discharge piping system when approved by the administrative authority and permitted by the manufactures installation instructions and installed with those instructions. Where a pan drain was not previously installed, a pan drain shall not be required for a replacement water heater installation. 57. The amendment of Section P2804.6.1, entitled Requirements for discharge piping, to read as follows: P2804.6.1 Requirements for discharge piping. The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: 1. Not be directly connected to the drainage system. 2. Discharge through an air gap located in the same room as the water heater. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. Exception: Multiple relief devices may be installed to a single T & P discharge piping system when approved by the administrative authority and permitted by the manufacturer’s installation instructions and installed with those instructions. 5. Discharge to the floor, to the pan serving the water heater or storage tank, to a waste receptor, to an approved location, or to the outdoors. [Items 6 through 14 remain unchanged] 58. The amendment of Section P2902.5.3, entitled Lawn irrigation systems, to read as follows: P2902.5.3 Lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by an atmospheric-type vacuum breaker, a pressure-type vacuum breaker, a double-check assembly or a reduced pressure principle backflow preventer. A valve shall not be installed downstream from an atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principle backflow preventer. 59. The amendment of Section P3003.9.2, entitled Solvent cementing, to read as follows: P3003.9.2 Solvent cementing. Joint surfaces shall be clean and free from moisture. A purple primer that conforms to ASTM F 656 shall be applied. Solvent cement not purple in color and conforming to ASTM D 2564, CSA B137.3, CSA B181.2 or CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D 2855. Solvent cement joints shall be permitted above or below ground. 60. The amendment of Section P3111, entitled COMBINATION WASTE AND VENT SYSTEM, by deleting the section in its entirety. 61. The amendment of Section P3112.2, entitled Vent Connection, by deleting and replacing said Section with the following: P3112.2 Installation. Traps for island sinks and similar equipment shall be roughed in above the floor and may be vented by extending the vent as high as possible, but not less than the drainboard height and then returning it downward and connecting it to the horizontal sink drain immediately downstream from the vertical fixture drain. The return vent shall be connected to the horizontal drain through a wye-branch fitting and shall, in addition, be provided with a foot vent taken off the vertical fixture vent by means of a wye-branch immediately below the floor and extending to the nearest partition and then through the roof to the open air or may be connected to other vents at a point not less than six (6) inches (152 mm) above the flood level rim of the fixtures served. Drainage fittings shall be used on all parts of the vent below the floor level and a minimum slope of one-quarter (1/4) inch per foot (20.9 mm/m) back to the drain shall be maintained. The return bend used under the drain-board shall be a one (1) piece fitting or an assembly of a forty-five (45) degree (0.79 radius), a ninety (90) degree (1.6 radius) and a forty-five (45) degree (0.79 radius) elbow in the order named. Pipe sizing shall be as elsewhere required in this Code. The island sink drain, upstream of the return vent, shall serve no other fixtures. An accessible cleanout shall be installed in the vertical portion of the foot vent. 62. The amendment of the Electrical Part (Chapters 34 through 43) of the International Residential Code by deleting in its entirety. The applicable code provisions are found in the Electrical Chapter of the Arlington City Code. E. The following local amendments to the International Energy Conservation Code (I.E.C.C.) are hereby adopted: 1. The I.E.C.C. contains both commercial ("C") and residential ("R") provisions. Where an amendment cites a section number with both a C and an R number, it is understood that both sections are amended respectively. 2. The amendment of Section C101.1/R101.1, entitled Title, is amended to read as follows: C101.1/R101.1 Title. This code shall be known as the International Energy Conservation Code of the City of Arlington, Texas, and shall be cited as such. It is referred to herein as "this code". 3. The amendment of Section C102.1/R102.1, entitled General, by adding Section C102.1.2, entitled Alternative compliance, and Section R102.1.2 (N1101.4.1), entitled Alternative compliance, and they shall both respectively read as follows: C102.1.2 Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the Code Official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. R102.1.2 (N1101.4.1) Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the Code Official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Regardless of the program or the path to compliance, each 1- and 2-family dwelling shall be tested for air and duct leakage as prescribed in Section R402.4.1.2 (N1102.4.1.2) and R403.3.3 (N1103.3.3) respectively. 4. The amendment of Section C105.2/R105.2, entitled Required Inspections, to read as follows: C105.2/R105.2 Required inspections. The code official, his or her designated agent or an approved agency, upon notification, shall make the inspections set forth in Sections C105.2.1 through C105.2.6. C105.2.1/R105.2.1 Footing and foundation inspection. Inspections associated with footings and foundations shall verify compliance with the code as to R-value, location, thickness, depth of burial and protection of insulation as required by the code and approved plans and specifications. C105.2.2/R105.2.2 Framing and Air Barrier rough-in inspection. Inspections at framing and rough-in shall be made before application of interior finish insulation and shall verify compliance with the code as to: air leakage controls as required by the code; and approved plans and specifications. C105.2.3/R105.2.3 Insulation and Fenestration rough-in inspection. Inspections at framing and rough-in shall be made before application of interior finish and shall verify compliance with the code as to: types of insulation and corresponding R-values and their correct location and proper installation; fenestration properties such as U-factor and SHGC and proper installation. C105.2.4/R105.2.4 Plumbing rough-in inspection. Inspections at plumbing rough-in shall verify compliance as required by the code and approved plans and specifications as to types of insulation and corresponding R-values and protection and required controls. C105.2.5/R105.5.5 Mechanical rough-in inspection. Inspections at mechanical rough-in shall verify compliance as required by the code and approved plans and specifications as to installed HVAC equipment type and size, required controls, system insulation and corresponding R-value, system air leakage control, programmable thermostats, dampers, whole-house ventilation, and minimum fan efficiency. Exception: Systems serving multiple dwelling units shall be inspected in accordance with Section C105.2.4. C105.2.6/R105.2.6 Final inspection. The building shall have a final inspection and shall not be occupied until approved. The final inspection shall include verification of the installation of all required building systems, equipment and controls and their proper operation and the required number of high-efficacy lamps and fixtures. 5. The amendment of Sections C104/R104, entitled FEES, by deleting in their entirety. 6. The amendment of Sections C109/R109, entitled STOP WORK ORDER, by amending the same to read as follows: SECTION C109/R109 STOP WORK ORDER C109.1/R109.1 Stop Work Order. Whenever any work is being done contrary to the provisions of this Code, the Building Official may order the work stopped by notice in writing served on any persons engaged in the doing or causing such work to be done. Any such person shall forthwith stop such work until: a. He or she is authorized by the Building Official to proceed with the work; or b. An appeal perfected pursuant to Section 2.06 of Article II has resulted in a waiver of the condition causing the stop order, or a finding that there is no cause for a stop order. Failure to stop such work, in addition to penalties and remedies elsewhere set forth, shall void any appeal. 7. The amendment of Section C110/R110, entitled MEANS OF APPEALS, by deleting in their entirety. 8. The amendment of Section R202 (N1101.6), entitled GENERAL DEFINITIONS, by adding the following definitions: DYNAMIC GLAZING. Any fenestration product that has the fully reversible ability to change it performance properties, including U-factor, solar heat gain coefficient (SHGC), or visible transmittance (VT). PROJECTION FACTOR. The ratio of the horizontal depth of the overhang, eave or permanently attached shading device, divided by the distance measured vertically from the bottom of the fenestration glazing to the underside of the overhang, eave or permanently attached shading device. 9. The amendment of Section R401.2.5, entitled Additional energy efficiency, by deleting in its entirety. 10. The amendment of Table 402.1.2, entitled MAXIMUM ASSEMBLY U- FACTORS AND FENESTRATION REQUIREMENT, by amending the following columns and rows to read as follows. Climate Zone | Fenestration U-Factorf | Ceiling U-Factor 2 | 0.40 | 0.029 3 | 0.32 | 0.029 11. The amendment of Table 402.1.3, entitled INSULATION MINIMUM R- VALUES AND FENESTRATION REQUIREMENTS BY COMPONENT, by amending the following columns and rows to read as follows: Climate Zone | Fenestration U-Factorb,i | Ceiling R-Value | Wood Frame Wall R-Value | Slab R-Value & Depth 2 | 0.40 | 42 | 13 or 0 + 10 | 0 3 | 0.32 | 42 | 19 or 13+53ci, 0+15 | 10ci, 2 ft 0 12. The amendment of Section C402.5.2, entitled Dwelling and sleeping unit enclosure testing, to read as follows: C402.5.2 Dwelling and sleeping unit enclosure testing. The building thermal envelope shall be tested in accordance with ASTM E779. ANSI/RESNET/ICC 380, ASTM E1827 or an equivalent method approved by the code official. The measured air leakage shall not exceed 0.30 cfm/ft2 (1.5 Us m2) of the testing unit enclosure area at a pressure differential of 0.2 inch water gauge (50 Pa). Where multiple dwelling units or sleeping units or other occupiable conditioned spaces are contained within one building thermal envelope, each unit shall be considered an individual testing unit, and the building air leakage shall be the weighted average of all testing unit results, weighted by each testing unit's enclosure area. Units shall be tested separately with an unguarded blower door test as follows: 1. Where buildings have fewer than eight testing units, each testing unit shall be tested. 2. For buildings with eight or more testing units, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit enclosure area. For each tested unit that exceeds the maximum air leakage rate, an additional three units shall be tested, including a mixture of testing unit types and locations. 13. The amendment of Section R402.4.1, entitled Building thermal envelope, by adding Section R402.4.1.4, entitled Sampling options for R2 multifamily dwelling units, which shall read as follows R402.4.1.4 Sampling options for R2 multifamily dwelling units. For buildings with eight or more testing units that must be tested as required by R402.1.2 or R402.1.3, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit enclosure area. For each tested unit that exceeds the maximum air leakage rate, an additional three units shall be tested, including a mixture of testing unit types and locations. Where buildings have fewer than eight testing units, each testing unit shall be tested. 14. The amendment of Section R402.4.6, entitled Electrical and communication outlet boxes (air-sealed boxes), to read as follows: R402.4.6 Electrical and communication outlet boxes (air-sealed boxes). Electrical and communication outlet boxes installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. 15. The amendment of Section R403.3, entitled Ducts, by adding Section R403.3.8, entitled Sampling options for R2 multifamily dwelling units, which shall read as follows: R403.3.8 Sampling options for R2 multifamily dwelling units. For buildings with eight or more testing units that must be tested as required by R403.3.5, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit floor area. For each tested unit that exceeds the maximum duct leakage rate, an additional three units shall be tested, including a mixture of testing unit types and locations. Where buildings have fewer than eight testing units, each testing unit shall be tested. 16. The amendment of Section R403.6, entitled Mechanical Ventilation, by adding Section R403.6.4, entitled Sampling options for R2 multifamily dwelling units, which shall read as follows: R403.6.4 Sampling options for R2 multifamily dwelling units. For buildings with eight or more testing units that must be tested as required by R403.6.3, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit floor area. For each tested unit that does not meet the minimum ventilation rate, an additional three units shall be tested, including a mixture of testing unit types and locations. Where buildings have fewer than eight testing units, each testing unit shall be tested. 17. The amendment of Section R404.2, entitled Interior Lighting Controls, by deleting in its entirety. 18. The amendment of Section R405.2, entitled Performance-based compliance, to read as follows. R405.2 Performance-based compliance. Compliance based on total building performance requires that a proposed design meets all of the following: 1. The requirements of the sections indicated within Table R405.2. 2. The building thermal envelope greater than or equal to levels of efficiency and solar heat gain coefficients in Table R402.1.1 or R402.1.3 of the 2009 International Energy Conservation Code. 3. An annual energy cost that is less than or equal to the annual energy cost of the 2021 standard reference design or 8% less than the annual energy cost of the 2018 standard reference design. Energy prices shall be taken from a source approved by the code official, such as the Department of Energy, Energy Information Administration's State Energy Data System Prices and Expenditures reports. Code officials shall be permitted to require time-of-use pricing in energy cost calculations. Exception: The energy use based on source energy expressed in Btu or Btu per square foot of conditioned floor area shall be permitted to be substituted for the energy cost. The source energy multiplier for electricity shall be 3.16. The source energy multiplier for fuels other than electricity shall be 1.1. 19. The amendment of TABLE R406.5 (N1106.4), entitled MAXIMUM ENERGY RATING INDEX, by amending the columns and rows below to read as follows: TABLE R406.5 (N1106.4) 1 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE ENERGY RATING INDEX 2 63 3 63 1 This table is effective until August 31, 2022. TABLE R406.5 (N1106.4) 2 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX 2 | 59 3 | 59 2 The table is effective from September 1, 2022 to August 31, 2025. TABLE R406.5 (N1106.4) 3 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX 2 | 57 3 | 57 3 The table is effective from September 1, 2025 to August 31, 2028. TABLE R406.5 (N1106.4) 3 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX 2 | 55 3 | 55 4 This table is effective on or after September 1, 2028. 20. The amendment of Section R408, entitled ADDITIONAL EFFICIENCY PACKAGE OPTIONS, by deleting in its entirety. 21. NOTE: HB 3215 was signed into law by the Governor on June 14, 2021, as part of the 87th Regular Session, and was codified in Chapter 388, Texas Building Energy Performance Standards: §388.003 (i), (j), and (k). HB 3215 now allows a Home Energy Rating System Index (ex. HERS Index) utilizing ANSI/RESNET/ICC Standard 301 (as it existed on January 1, 2021) shall be considered in compliance with State law provided that: • The home includes compliance with the Mandatory requirements of 2018 IECC Section R406.2. • The home includes compliance with Building thermal envelope provisions of Table R402.1.2 or Table R402.1.4 of the 2018 IECC. F. The following local amendments to the International Existing Building Code (I.E.B.C.) are hereby adopted: 1. The amendment of Section 102.4, entitled Referenced codes and standards., to read as follows: 102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each reference and as further regulated in Sections 102.4.1 and 102.4.2. Exception: Where enforcing a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing shall govern. 2. The amendment of Section 105, entitled PERMITS, by deleting in its entirety. 3. The amendment of Section 106, entitled CONSTRUCTION DOCUMENTS, by deleting in its entirety. 4. The amendment of Section 108, entitled FEES, by deleting in its entirety. 5. The amendment of Section 109, entitled INSPECTIONS, by deleting in its entirety. 6. The amendment of Section 110, entitled CERTIFICATE OF OCCUPANCY, by deleting in its entirety. 7. The amendment of Section 112, entitled MEANS OF APPEALS, by deleting in its entirety. 8. The amendment of Section 113, entitled VIOLATIONS, by deleting in its entirety. 9. The amendment of Section 114, entitled STOP WORK ORDER, by amending it in its entirety to read as follows: SECTION 114 STOP WORK ORDER 114.1 Stop work orders. Whenever any work is being done contrary to the provisions of this Code, the Building Official may order the work stopped by notice in writing served on any persons engaged in the doing or causing such work to be done. Any such person shall forthwith stop such work until: a. He or she is authorized by the Building Official to proceed with the work; or b. An appeal perfected pursuant to Section 2.05 has resulted in a waiver of the condition causing the stop order, or a finding that there is no cause for a stop order. Failure to stop such work, in addition to penalties and remedies elsewhere set forth, shall void any appeal. 10. The amendment of Section 115, entitled UNSAFE STRUCTURES AND EQUIPMENT, by deleting in its entirety. 11. The amendment of Section 202, entitled GENERAL DEFINITIONS, by amending the definition of EXISTING BUILDING to read as follows: EXISTING BUILDING. A building, structure, or space with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; a building, structure or space that is undergoing a change of occupancy or use. 12. The amendment of Section 306.1, entitled Scope., by adding the following Exceptions, which shall read as follows: Exceptions: 1. Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of this chapter. 2. If the cost of the project is less than $50K, it must comply with ICC A117.1, or it shall be reviewed and inspected to the Texas Accessibility Standards by a Registered Accessibility Specialist. 13. The amendment of Section 306.2, entitled Design., by adding the following Exception, which shall read as follows: Exception: Projects subject to the Texas Accessibility Standards as adopted by the Texas Department of Licensing and Regulation are exempt from this section. Projects with a valuation of less than $50,000.00 (which are subject to the Texas Accessibility Standards) may be accepted as equivalent to this section where reviewed and inspected to the Texas Accessibility Standards by a Texas Department of Licensing and Regulation Registered Accessibility Specialist when a plan review report and a compliant inspection report are provided to the building code official. 14. The amendment of Section 306.5, entitled Change of occupancy., by adding Section 306.5.1, entitled Complete change of occupancy., which shall read as follows: 306.5.1 Complete change of occupancy. Where an entire building undergoes a change of occupancy, it shall comply with Section 305.4.1 and shall have all of the following accessible features: 1. Not fewer than one accessible building entrance. 2. Not fewer than one accessible route from an accessible building entrance to primary function areas. 3. Signage complying with Section 1111 of the International Building Code. 4. Accessible parking, where parking is being provided. 5. Not fewer than one accessible passenger loading zone, where loading zones are provided. 6. Not fewer than one accessible route connecting accessible parking and accessible passenger loading zones to an accessible entrance. 7. At least one accessible family or assisted use toilet room shall be provided in accordance with Chapter 11 of the International Building Code. Where it is technically infeasible to comply with the new construction standards for any of these requirements for a change of group or occupancy, Items 1 through 6 shall conform to the requirements to the maximum extent technically feasible. Exception: The accessible features listed in Items 1 through 6 are not required for an accessible route to Type B units. 15. The amendment of Section 401.3, entitled Flood hazard areas., by deleting in its entirety. 16. The amendment of Section 405.2.6, entitled Flood hazard areas., by deleting in its entirety. 17. The amendment of Section 406.1, entitled Material., to read as follows: 406.1 Material. Existing electrical wiring and equipment undergoing repair shall be allowed to be repaired or replaced with like material, in accordance with the requirements of NFPA 70. 18. The amendment of Section 502.3, entitled Flood hazard areas., by deleting in its entirety. 19. The amendment of Section 503.2, entitled Flood hazard areas., by deleting in its entirety. 20. The amendment of Section 503.16, entitled Enhanced classroom acoustics., by adding an Exception, which shall read as follows: Exception: Compliance with the Texas Accessibility Standards is not considered equivalent compliance for the purpose of this code section. 21. The amendment of Section 504.1.2, entitled Existing fire escapes., to read as follows: 504.1.2 Existing fire escapes. Existing fire escapes shall continue to be accepted as a component in the means of egress in existing buildings only. Existing fire escapes shall be permitted to be repaired or replaced. 22. The amendment of Section 504.1.3, entitled New fire escapes., by deleting in its entirety. 23. The amendment of Section 507.3, entitled Flood hazard areas., by deleting in its entirety. 24. The amendment of Section 701.3, entitled Flood hazard areas., by deleting in its entirety. 25. The amendment of Section 702.4, entitled Window opening control devices on replacement windows., by adding a second Exception, which shall read as follows: 2. Operable windows with openings that are provided with window fall prevention devices that comply with ASTM F2090. 26. The amendment of Section 702.7, entitled Materials and methods., to read as follows: 702.7 Materials and methods. All new work shall comply with the materials and methods requirements in the International Building Code, International Energy Conservation Code, International Mechanical Code, National Electrical Code, and International Plumbing Code, as applicable, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building. 27. The amendment of Section 802.5.1, entitled Minimum requirement., to read as follows: 802.5.1 Minimum requirement. Every portion of open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps, and landings that is more than 30 inches (762 mm) above the floor or grade below and is not provided with guards, or those in which the existing guards are judged to be in danger of collapsing, shall be provided with guards. 28. The amendment of Section 803.1, entitled Scope., by adding a second paragraph, which shall read as follows: For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls capable of resisting the passage of smoke containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. 29. The amendment of Section 803.2.6, entitled Supervision., by amending the Exception to read as follows: Exception: Supervision is not required where the Fire Code does not require such for new construction. 30. The amendment of Section 803.3, entitled Standpipes., to read as follows: 803.3 Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive standpipe requirements. 31. The amendment of Section 804.2, entitled General., by deleting Exception 1 in its entirety. 32. The amendment of Section 804.4.1.2, entitled Fire escapes required., to read as follows: 804.4.1.2 Fire Escapes required. For other than Group I-2, where more than one exit is required, an existing fire escape complying with Section 805.3.1.2.1 shall be accepted as providing one of the required means of egress. 33. The amendment of Section 804.4.1.2.1, entitled Fire escape access and details., to read as follows: Section 804.4.1.2.1 Fire escape access and details. Fire escapes shall comply with all of the following requirements: 1. Occupants shall have unobstructed access to the fire escape without having to pass through a room subject to locking. 2. Access to a fire escape shall be through a door, except that windows shall be permitted to provide access from single dwelling units or sleeping units in Group R-1, R-2 and I-1 occupancies or to provide access from spaces having a maximum occupant load of 10 in other occupancy classifications. 2.1 The window shall have a minimum net clear opening of 5.7 square feet (0.53 m2) or 5 square feet (0.46 m2) where located at grade. 2.2 The minimum net clear opening height shall be 24 inches (610 mm) and net clear opening width shall be 20 inches (508 mm). 2.3 The bottom of the clear opening shall not be greater than 44 inches (1118 mm) above the floor. 2.4 The operation of the window shall comply with the operational constraints of the International Building Code. 3. {deleted} 4. Openings within 10 feet (3048 mm) of fire escape stairways shall be protected by fire assemblies having minimum ¾-hour fire resistance ratings. Exception: Opening protection shall not be required in buildings equipped throughout with an approved automatic sprinkler system. 5. In buildings of Group E occupancy, up to and including the 12th grade, buildings of Group I occupancy, boarding houses and childcare centers, ladders of any type are prohibited on fire escapes used as a required means of egress. 34. The amendment of Section 804.6.2, entitled Transoms., to read as follows: 804.6.2 Transoms. In all buildings of Group B, E, I-1, I-2, R-1 and R-2 occupancies, all transoms in corridor walls in work areas shall be either glazed with 1/4-inch (6.4 mm) wired glass set in metal frames or other glazing assemblies having a fire protection rating as required for the door and permanently secured in the closed position or sealed with materials consistent with the corridor construction. 35. The amendment of Section 904.1, entitled Automatic sprinkler systems., to read as follows: 904.1 Automatic sprinkler systems. An automatic sprinkler system shall be provided in a work area where required by Section 803.2 or this section. For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. 36. The amendment of Section 904.1.1, entitled High-rise buildings., to read as follows: 904.1.1 High-rise buildings. An automatic sprinkler system shall be provided in work areas of high-rise building. 37. The amendment of Section 1011.2.1., entitled Fire sprinkler system., to read as follows: 1011.2.1 Fire sprinkler system. Where a change in occupancy classification occurs or where there is a change of occupancy within a space where there is a different fire protection system threshold requirement in Chapter 9 of the International Building Code that requires an automatic fire sprinkler system to be provided based on the new occupancy in accordance with Chapter 9 of the International Building Code. The installation of the automatic sprinkler system shall be required within the area of the change of occupancy and areas of the building not separated horizontally and vertically from the change of occupancy by one of the following: 1. Fire barrier, as required by Section 707 of the IBC. 2. Fire wall, as required by Section 706 of the IBC. Exceptions: 1. An automatic sprinkler system shall not be required in a one-or two-family dwelling constructed in accordance with the International Residential Code. 2. Automatic sprinkler system shall not be required in a townhouse constructed in accordance with the International Residential Code. 3. The townhouse shall be separated from adjoining units in accordance with Section R302.2 of the International Residential Code. 38. The amendment of Section 1102.2, entitled Area limitations., by adding Section 1102.2.1, entitled Fire separations., which shall read as follows: 1102.2.1 Fire separations. Where fire separations are utilized to allow additions without exceeding the allowable area provisions of Chapter 5 of the IBC for either the existing building or the new addition, the decreased clear space where the two buildings adjoin shall be accounted for in such calculation relative to the allowable frontage increase. 39. The amendment of Section 1103.3, entitled Flood hazard areas., by deleting in its entirety. 40. The amendment of Section 1201.4, entitled Flood hazard areas., by deleting in its entirety. 41. The amendment of Section 1301.3.2, entitled Compliance with other codes., to read as follows: 1301.3.2 Compliance with other codes. Buildings that are evaluated in accordance with this section shall comply with the International Fire Code. 42. The amendment of Section 1301.3.3, entitled Flood hazard areas., by deleting in its entirety. 43. The amendment of Section 1402.6, entitled Flood hazard areas., by deleting in its entirety. 44. The amendment of Section 1509, entitled WATER SUPPLY FOR FIRE PROTECTION, by deleting in its entirety and replacing with the following: SECTION 1509 WATER SUPPLY FOR FIRE PROTECTION 1509.1 When required An approved water supply for fire protection, either temporary or permanent, shall be made available as soon as combustible material arrives on the site. The water supply design and the timing of the water supply installation relative to building construction shall comply with the adopted Fire Code. G. The following local amendments to the International Swimming Pool and Spa Code (I.S.P.S.C.) are hereby adopted: 1. The deletion of Section 101.1, entitled Title. 2. The deletion of Section 101.3, entitled Purpose. 3. The amendment of Section 102.9, entitled Other laws, to read as follows: Section 102.9 Other laws. The provisions of this code shall not be deemed to nullify any provisions of local, state or federal law, including but not limited to the following: 1. Texas Department of State Health Services (TDSHS); Standards for Public Pools and Spas; §285.181 through §285.208, (TDSHS rules do not apply to pools serving one- and two-family dwellings or townhouses). 2. Texas Department of Licensing and Regulation (TDLR); 2012 Texas Accessibility Standards (TAS), TAS provide the scoping and technical requirements for accessibility for Swimming Pool, wading pools and spas and shall comply with 2012 TAS, Section 242. (TAS rules do not apply to pools serving one- and two-family dwellings or townhouses). Exception: Elements regulated under Texas Department of Licensing and Regulation (TDLR) and built-in accordance with TDLR approved plans, including any variances or waivers granted by the TDLR, shall be deemed to comply with the requirements of this Chapter. 4. The amendment of Section 103.1, entitled Creation of enforcement agency, to read as follows: Section 103.1 Creation of enforcement agency. The City of Arlington Building Inspections Department is hereby created and the official in charge thereof shall be known as the Building Official. The City of Arlington Code Compliance Services Department is hereby created and the official in charge thereof shall be known as the Code Official for operation and maintenance of any public swimming pool in accordance with this code, local and state law. 5. The amendment of Section 104.6, entitled Right of entry, to read as follows: 104.6 Right of entry. Whenever necessary to make an inspection to enforce any of the provisions of this Code, or whenever the Administrative Authority or their authorized representative has reasonable cause to believe that there exists in any building or upon any premises any condition or code violation which makes such building or premises unsafe, dangerous or hazardous, the Administrative Authority or their authorized representative may enter such building or premises at all reasonable times to inspect the same or to perform any duty imposed upon the Administrative Authority by this Code. If such building or premises be unoccupied, they shall first make a reasonable effort to locate the owner or other persons having charge or control of the building or premises and request entry. If such entry is refused, or if no owner or other person having charge or control of the building or premises can be located, the Administrative Authority or their authorized representative shall obtain a warrant pursuant to the "Municipal Court" Chapter of the Code of the City of Arlington. 6. The amendment of Section 105.4, entitled Permit issuance, to read as follows: 105.4 Permit issuance. The application, plans, specifications, computations, and other data filed by an applicant for permit shall be reviewed by the Administrative Authority. Such plans may be reviewed by other departments of this jurisdiction to verify compliance with applicable laws under their jurisdiction. If the Administrative Authority finds that the work described in an application for a permit and the plans, specifications and other data filed therewith conform to the requirements of this Code and other pertinent laws and ordinances and that the fees specified in Section 105.6 have been paid, they shall issue a permit therefore to the applicant. "Applicant" in this usage shall conform to the provisions of Sections 4.01 of the Construction Chapter of the Arlington City Code. 7. The amendment of Section 105.6, entitled Fees and refunds, to read as follows: 105.6 Fees and refunds. Any person, firm or corporation desiring a permit as required by this Building Code shall, at or before the time of permit issuance, pay a fee as specified in the fee structure as approved by the City Council of the City of Arlington by resolution and which may be amended from time to time by said City Council. 8. The amendment of Section 106.1, entitled Construction documents, by adding the following paragraph: Design, construction, or renovation of Class A and Class B pools and spas, therapeutic pools and spas, surf pools, wave pools, and pools with a movable bottom, drop slide, or waterslide constructed on or after the effective date of this amendment shall be planned and designed by a licensed engineer. 9. The amendment of Section 107.3, entitled Prosecution of violation, by deleting it in its entirety. 10. The amendment of Section 110.13, entitled Testing, to read as follows: 110.13 Testing. Pool and Spa systems shall be tested as required in this code and in accordance with Sections 110.14 through 110.16. Tests shall be made by the permit holder and may be observed by the Building Official, his designee, or the Code Compliance Services Department. 11. The amendment of Section 111, entitled MEANS OF APPEAL, by deleting in its entirety. 12. The amendment of Section 112, entitled BOARD OF APPEALS, by amending in its entirety to read as follows: SECTION 112 BOARD OF APPEALS 112.1 Board of Appeals. The Building Code Board of Appeals shall act as a Board of Appeals as provided in Article II of this Chapter. 13. The amendment of Section 113.4, entitled Violation penalties, to read as follows: 113.4 Violation Penalties. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert or demolish, equip, use or maintain any mechanical systems or equipment or cause or permit the same to be done in violation of this Code. A person convicted of violating any of the provisions of this Code shall be guilty of a misdemeanor and each day or portion thereof during which any such violation continues shall be a separate offense. Each offense shall be punishable by a fine of not more than $2,000.00. The issuing or granting of a permit or approval of plans and specifications by the City shall not be deemed or construed to be a permit for, or an approval of, any violation of any of the provisions of this Code or any other ordinance of the City. No permit presuming to give authority to violate or cancel the provisions of this Code, or any other ordinance of the City, shall be valid, except insofar as the work or use which is authorized is lawful. The issuing or granting of a permit or approval of plans by the City shall not prevent the Administrative Authority from thereafter requiring the correction of errors in said plans and specifications or from preventing construction operations being carried on thereunder when in violation of this Code or of any other ordinance of the City, or from revoking any certificate of approval when issued in error. 14. The amendment of Section 114, entitled STOP WORK ORDER, by amending it in its entirety to read as follows: SECTION 114 STOP WORK ORDER 114.1 Stop work orders. Whenever any work is being done contrary to the provisions of this Code, the Building Official may order the work stopped by notice in writing served on any persons engaged in the doing or causing such work to be done. Any such person shall forthwith stop such work until: a. He or she is authorized by the Building Official to proceed with the work; or b. An appeal perfected pursuant to Section 2.05 has resulted in a waiver of the condition causing the stop order, or a finding that there is no cause for a stop order. Failure to stop such work, in addition to penalties and remedies elsewhere set forth, shall void any appeal. 15. The amendment of Section 202, entitled DEFINITIONS, by adding the definitions of "Building Code", "Existing Pool or Spa System", "Code Compliance Services Department", and "Shall", and amending the definition of "Code Official": BUILDING CODE. The "Construction" Chapter of the Code of the City of Arlington, 1987, as amended. CODE OFFICIAL. The officer or other designated authority charged with the administration and enforcement of this code, or a duly authorized representative. The Code Official is also the Building Official and Administrative Authority. CODE COMPLIANCE SERVICES DEPARTMENT. The team regulating the operation of public pools. Routine inspections on pools and spas open to the public are conducted to document compliance with the standards set forth in State law. EXISTING POOL or SPA SYSTEM. Any system, apparatus or equipment that has been approved for operation within the City by the Administrative Authority prior to the adoption of this Code. SHALL. As it applies to an act or duty to be performed by the Administrative Authority pursuant to any section of this Code, is discretionary. Its use in all other applications in this Code shall be mandatory. 16. The amendment of Section 305.1, entitled General., to read as follows: Section 305.1 General. The provisions of this section shall apply to the design of barriers for restricting entry into areas having pools and spas. In only one-and two-family dwellings and townhouses, where spas or hot tubs are equipped with a lockable safety cover complying with ASTM F1346 and swimming pools are equipped with a powered safety cover that complies with ASTM F1346, the areas where those spas, hot tubs or pools are located shall not be required to comply with Sections 305.2 through 305.7. 17. The amendment of Section 305.2.7., entitled Chain link dimensions, by adding Section 305.2.7.1, entitled Chain link fencing prohibited, which shall read as follows: 305.2.7.1 Chain link fencing prohibited. Chain link fencing is not permitted as a barrier in public pools built after January 1, 1994. 18. The amendment of Section 305.4, entitled Structure wall as a barrier, by amending the first paragraph to read as follows: 305.4 Structure wall as a barrier. Where a wall of a dwelling or structure of a one- and two-family dwelling or townhouse or its accessory structure serves as part of a barrier and where doors or windows provide direct access to the pool or spa through that wall, one of the following shall be required: 19. The amendment of Section 305.6, entitled Natural barriers, to read as follows: 305.6 Natural barriers used in a one- and two-family dwelling or townhouse. In the case where the pool or spa area abuts the edge of a lake or other natural body of water, public access is not permitted or allowed along the shoreline, and required barriers extend to and beyond the water’s edge a minimum of eighteen (18) inches, a barrier is not required between the natural body of water shoreline and the pool or spa. 20. The amendment of Section 307.1.4., entitled Accessibility, by adding an Exception, which shall read as follows: Exception: Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to comply with the requirements of this chapter. 21. The amendment of Section 307.2.2, entitled Materials and structural design., by adding Section 307.2.2.2, entitled Adjacency to Structural Foundation, which shall read as follows: Section 307.2.2.2. Adjacency to Structural Foundation. Depth of the swimming pool and spa shall maintain a ratio of 1:1 from the nearest building foundation or footing of a retaining wall. Exception: A sealed engineered design drawing of the proposed new structure shall be submitted for approval. 22. The amendment of Section 310.1, entitled General., to read as follows: 310.1 General. Suction entrapment avoidance for pools and spas shall be provided in accordance with APSP 7 (ANSI/PHTA/ICC 7) or for public swimming pools in accordance with State of Texas Rules for Public Swimming Pools and Spas, Title 25 TAC Chapter 265 Subchapter L, Rule §265.190. Exceptions: 1. Portable spas and portable exercise spas listed and labeled in accordance with UL 1563 or CSA C22.2 No. 218.1 2. Suction entrapment avoidance for wading pools shall be provided in accordance with Section 405. 23. The amendment of Section 402.12, entitled Water envelopes, by amending in its entirety to read as follows: 402.12. Water envelopes. The minimum diving water envelopes shall be in accordance with Table 402.12 Texas Department of State Health Services, Administrative Code Title 25, Chapter 265, Section 186 (e) and Figure: 25 TAC 256.186 (e) (6). Table 402.12 Texas Department of State Health Services, Administrative Code Title 25, Chapter 265, Section 186 (e) Maximum Diving Board Height Over Water | ¾ Meter | 1 Meter | 3 Meters Max. Diving Board Length | 12 ft. | 16 ft. | 16 ft. Minimum Diving Board Overhang | 2 ft. 6 in. | 5 ft. | 5 ft. D1 Minimum | 8 ft. 6 in. | 11 ft. 2 in. | 12 ft. 2 in. D2 Minimum | 9 ft. | 10 ft. 10 in. | 11 ft. 10 in. D3 Minimum | 4 ft. | 6 ft. | 6 ft. L1 Minimum | 4 ft. | 5 ft. | 5 ft. L2 Minimum | 12 ft. | 16 ft. 5 in. | 19 ft. 9 in. L3 Minimum | 14 ft. 10 in. | 13 ft. 2 in. | 13 ft. 11 in. L4 Minimum | 30 ft. 10 in. | 34 ft. 7 in. | 38 ft. 8 in. L5 Minimum | 8 ft. | 10 ft. | 13 ft. H Minimum | 16 ft. | 16 ft. | 16 ft. From Plummet to Pool Wall at Side | 9 ft. | 10 ft. | 11 ft. 6 in. From Plummet to Adjacent 10 ft. 10 ft. 10 ft. Plummet Figure: 25 TAC 256.186 (e) (6) H (Overhead Obstruction or Ceiling) 2’6” Min. Pt A Pt. B Pt. C 4’Min 4’6” Min D 11 Max D2 D1 R 6’6”Typical 1 30º Max. 10 Max Slope L1 L2 L3 Typical L4 4’Min 4’Min L5 10’ (1 Meter) 24. The amendment of Section 411.2, entitled Pool stairs, by amending Section 411.2.1 and Section 411.2.2 to read as follows: 411.2.1 Tread dimensions and area. Treads shall have a minimum unobstructed horizontal depth (i.e., horizontal run) of 12 inches and a minimum width of 20 inches. not be less than 24 inches (607mm) at the leading edge. Treads shall have an unobstructed surface area of not less than 240 square inches (154838mm2) and an unobstructed horizontal depth of not less than10 inches (254 mm) at the center line. 411.2.2 Risers. Risers for steps shall have a maximum uniform height of 10 inches, with the bottom riser height allowed to taper to zero except for the bottom riser, shall have a uniform height of not greater than 12 inches (305 mm) measured at the center line. The bottom riser height is allowed to vary to the floor. 25. The amendment of Section 411.5.1, entitled Swimouts, to read as follows: 411.5.1 Swimouts. Swimouts, located in either the deep or shallow area of a pool, shall comply with all of the following: 1. The horizontal surface shall be no greater than 20 inches (508 mm) below the waterline. 2. An unobstructed surface shall be provided that is equal to or greater than that required for the top tread of the pool stairs in accordance with Section 411.2. 3. Where used as an entry and exit access, swimouts shall be provided with steps that comply with the pool stair requirements of Section 411.2. 4. The leading edge shall be visibly set apart and provided with a horizontal solid or broken stripe at least 1 inch wide on the top surface along the front leading edge of each step. This stripe shall be plainly visible to persons on the pool deck. The stripe shall be a contrasting color to the background on which it is applied, and the color shall be permanent in nature and shall be a slip-resistant surface. 26. The amendment of Section 411.5.2, entitled Underwater seats and benches, by amending Item 5 to read as follows: 5. The leading edge shall be visually set apart and provided with a horizontal solid or broken stripe at least 1 inch wide on the top surface along the front leading edge of each step. This stripe shall be plainly visible to persons on the pool deck. The stripe shall be a contrasting color to the background on which it is applied, and the color shall be permanent in nature and shall be a slip-resistant surface. 27. The amendment of Section 610.5.1., entitled Uniform height of 9 inches., shall be retitled and amended to read as follows: 610.5.1 Uniform height of 10 inches. Except for the bottom riser, risers at the centerline shall have a maximum uniform height of 10 inches (254 mm). The bottom riser height shall be permitted to vary from the other risers. 28. The amendment of Section 804.1, entitled General., to read as follows: Section 804.1 General. The minimum diving water envelopes shall be in accordance with Table 804.1 and Figure 804.1, or the manufacturer’s specifications, whichever is greater. Negative construction tolerances shall not be applied to the dimensions of the minimum diving water envelopes given in Table 804.1. H. Notwithstanding any other requirements in this Building Code, the following standards are hereby adopted for all applicable Multi-Family and Mixed-Use Developments: GREEN BUILDING PERFORMANCE STANDARDS FOR MULTI-FAMILY AND MIXED-USE DEVELOPMENT A. Applicability 1. This ordinance applies to: a) Any new construction of multi-family and residential mixed-use developments; and b) Any existing structure that requires substantial reconstruction to be converted from a commercial use to a multi-family or residential mixed-use occupancy c) Any existing multi-family structure that requires substantial reconstruction as part of a single project. 2. Substantial reconstruction means the project involves either: a) Demolition or rebuilding of 50% or more of the gross floor area, or b) Removal, replacement, or structural alteration of 50% or more of the building’s exterior walls and roof assembly. 3. This chapter does not apply to interior renovations, maintenance, or repairs that do not meet the thresholds above. 4. A new multi-family or mixed-use project that has been approved by the City Council through a Development Plan for a Planned Development (PD) for Residential Multi-Family-22 (RMF-22) uses, a Multi-Family Development Plan, or a Mixed-Use Development Plan, prior to September 1, 2025, is exempt from this chapter until September 1, 2030, at which time any permit shall be subject to the regulations contained herein. B. Intent It is the intent that the International Code sections referenced in this chapter serve as directional guides, as specific section numbering and captions may be amended from time to time through the International Code Council’s (ICC) ongoing code development cycles and the City’s adoption thereof. The building codes most recently adopted by the City of Arlington, and any local amendments thereto, shall serve as the baseline measurement for all regulations contemplated by this Chapter. Modifications included in this Chapter are intended to be specific code provisions. In the event of direct conflict between any future adopted building codes and the provisions contained in this Chapter, the most stringent regulation shall control. C. Definitions The following terms when used in this Chapter have the meanings ascribed to them in this section. 1. Mixed-use residential, when used to describe land use or development, means the use or development, as applicable, of a site consisting of residential and nonresidential uses in which the residential uses are at least 65 percent of the total square footage of the development. The term includes the use or development of a condominium. 2. Multi-family residential, when used to describe land use or development, means the use or development, as applicable, of a site for three or more dwelling units within one or more buildings. The term includes the use or development of a residential condominium. D. Required Performance Standards Any construction subject to this chapter, regardless of the designated zoning classification of the land on which it will be constructed, shall conform to the following enhanced performance standards. 1. Energy & Efficiency requirements otherwise established by Sections 403 and 406 and Appendix CB of the 2021 International Energy Conservation Code (IECC) are supplemented or amended to provide for: a) Minimum 10% improvement over IECC baseline performance. b) Net-zero ready infrastructure (solar- and battery-ready). c) All-electric HVAC and appliance infrastructure. d) High-efficiency HVAC (SEER 16 or higher). 2. Indoor Environmental Quality requirements otherwise established by Sections 806, 1202, and 1206 of the 2021 International Building Code (IBC) and Sections 403 and 605 of the 2021 International Mechanical Code (IMC) are supplemented or amended to provide for: a) Minimum MERV 13 air filtration. b) ASHRAE 62.2 compliant ventilation. c) VOC limits per ASHRAE/ASTM. d) STC/IIC ≥ 50 for total acoustic separation (walls, floors and ceilings). 3. Water Efficiency requirements otherwise established by Section 604, Section 1301, and Appendix C of the 2021 International Plumbing Code (IPC) are supplemented or amended to provide for: a) Toilets ≤1.0 gpf, Showers ≤1.5 gpm, Faucets ≤1.0 gpm. b) Rainwater/graywater reuse infrastructure readiness. c) Smart irrigation controllers required. 4. Roofing Performance requirements otherwise established by Chapter 15 the 2021 International Building Code (IBC) are supplemented or amended to provide for: a) High-albedo roofing: SRI ≥ 78 (low-slope), SRI ≥ 29 (steep-slope). b) On-site stormwater runoff mitigation. c) UL 2218 or FM 4473 Class 4 hail resistance. 5. Construction Waste & Indoor Air Quality requirements otherwise established by Chapter 33 of the 2021 International Building Code (IBC) are supplemented or amended to provide for: a) Minimum 75% diversion of construction/demolition waste. b) Indoor Air Quality (IAQ) management plan required during construction. 6. Transportation & Access requirements otherwise established by Chapters 4 and 11 of the 2021 International Building Code (IBC) and Section C405 of the International Energy Conservation Code (IECC) are supplemented or amended to provide for: a) Bicycle parking: 1 space per 5 units. b) EV Charging: i.) 1.5 EV charging stations for every 10 dwelling units (charging stations for at least 15% of parking); and ii.) 2.5 EV ready parking spaces for every 10 dwelling units (infrastructure readiness for at least 25% of parking); and iii.) Resulting in a site total of 40% EV-ready or EV-installed parking spaces. c) CPTED-compliant lighting: full cut-off, 1.0 footcandle minimum. 7. Safety & Security (CPTED) requirements otherwise established by Chapter 4 as well as Sections 404, 406, and 1205 of the 2021 International Building Code (IBC) are supplemented or amended to provide for: a) Uniform lighting at entries, walkways, and parking. b) Clear landscaping (≤3-ft shrubs, ≥7-ft tree canopies). c) Marked and illuminated unit entries. d) Visual/physical boundaries between public and private space.

Amended by Ord. No. 25-075, passed 9-16-2025.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.