§ 1.07 — National Electrical Code
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Electrical Code Chapter, § 1.07
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/0acd2a91-b930-4787-9b83-1580b2cac9f6
Section 1.07 National Electrical Code
A. Adoption: The National Electrical Code, 2020 Edition, as published by the National Fire Protection Association, referred to herein as "NEC", is hereby adopted and designated as the Electrical Code of the City of Arlington, the same as though such Code were copied at length herein, subject, however, to the deletions, amendments and addenda provided in Section 1.07(B) hereof. A copy of the NEC is filed in the office of the Building Official of the City of Arlington, Texas. B. Additions, Amendments and Deletions: The National Electrical Code, as adopted in Section 1.07(A) hereof, is hereby modified by the following deletions, amendments and addendums. These additions, amendments and deletions shall have precedence in any case where they are in conflict with the National Electrical Code adopted in Section 1.07(A) above. 1. The amendment of Article 100, entitled Definition, by adding the following term: Engineering Supervision. Supervision by a Qualified State of Texas Licensed Professional Engineer engaged primarily in the design or maintenance of electrical installations. 2. The amendment of Article 110.2, entitled Approval, to hereafter read as follows: 110.2 Approval. The conductors and equipment required or permitted by this Code shall be acceptable only if approved. Approval of equipment may be evident by listing and labeling of equipment by a Nationally Recognized Testing Lab (NRTL) with a certification mark of that laboratory or a qualified third-party inspection agency or a field evaluation by a Field Evaluation Body accredited by either the International Code Council International Accreditation Service AC354 or ANSI National Accreditation Board programs and approved by the Authority Having Jurisdiction (AHJ). Exception: Unlisted equipment that is relocated to another location within a jurisdiction or is field modified is subject to the approval by the AHJ. This approval may be by a field evaluation by a NRTL or qualified third-party inspection agency or a field evaluation by a Field Evaluation Body accredited by either the ICC IAS AC354 or ANAB programs and approved by the AHJ. Informational Note No. 1: See 90.7, Examination of Equipment for Safety, and 110.3, Examination, Identification, Installation, and Use of Equipment. See definitions of Approved, Identified, Labeled, and Listed. Informational Note No. 2: Manufacturer’s self-certification of equipment may not necessarily comply with U.S. product safety standards as certified by an NRTL. Informational Note No. 3: National Fire Protection Association (NFPA) 790 and 791 provide an example of an approved method for qualifying a third-party inspection agency. 3. The amendment of Table 210.24, entitled Summary of Branch-Circuit Requirements, to hereafter read as follows: Table 210.24 Summary of Branch-Circuit Requirements Circuit Rating | 15A | 20A | 30A | 40A | 50A Conductors (min. size) Circuit wires1 | 12 | 12 | 10 | 8 | 6 Taps | 12 | 12 | 12 | 12 | 12 Fixture wires & cords – see 240.5 Overcurrent Protection | 15 A | 20 A | 30 A | 40 A | 50A Outlet devices: Lampholders Permitted | Any type | Any type | Heavy Duty | Heavy Duty | Heavy Duty Receptacle Rating2 | 15 max. A | 15 or 20 A | 30 A | 40 or 50 A | 50A Maximum Load | 15 A | 20 A | 30 A | 40 A | 50A Permissible Load | See 210.23(A) | See 210.23(A) | See 210.23(B) | See 210.23(C) | See 210.23 (C) 1 These gauges are for copper conductors 2 For receptacle rating of cord-connected electric-discharge luminaires, see 410.30(C) 4. The amendment of Article 230.70(A)(1), entitled Readily Accessible Location, so that it shall hereafter read as follows: (1) Readily Accessible Location. The service disconnecting means shall be installed at a readily accessible location either outside of a building or structure or inside nearest the point of entrance of the service conductors. Three-phase services to non-residential occupancies shall have the disconnecting means located on the exterior of the building or structure when the metering equipment is located on the exterior of the building or structure. 5. The amendment of Table 311.12(A), entitled Minimum Size of Conductors, to hereafter read as follows: Table 311.12(A) Minimum Size of Conductors1 Conductor Voltage Rating (Volts) | Minimum Conductor Size (AWG) Copper | Aluminum or Copper- Clad Aluminum 0-2000 | 12 | 1/0 2001-8000 | 8 | 1/0 8001-15,000 | 2 | 1/0 15,001-28,000 | 1 | 1/0 28,001-35,000 | 1/0 | 1/0 1 Exception: An equipment grounding conductor within a listed cable assembly. 6. The amendment of Article 410.118, entitled Access to other boxes, to hereafter read as follows: 410.118 Access to other boxes. Luminaires recessed in the ceilings, floors, or walls shall not be used to access outlet, pull, or junction boxes or conduit bodies, unless the box or conduit body is an integral part of the listed luminaire. Exception: removable luminaires with a minimum measurement of 22 in. X 22 in. shall be permitted to be used as access to outlet, pull, junction boxes or conduit bodies. 7. The amendment of Article 422.31(B), entitled Appliances Rated over 300 Volt-Amperes, to hereafter read as follows: (B) Appliances Rated over 300 Volt-Amperes. For permanently connected appliances rated over 300 volt-amperes, the branch-circuit switch or circuit breaker shall be permitted to serve as the disconnecting means where the switch or circuit breaker is within sight from and is readily accessible to the appliance it serves or is capable of being locked in the open position in accordance with 110.25 and is readily accessible to the appliance it serves. Informational Note No. 1: For appliances employing unit switches, see 422.34. Informational Note No 2: The following means of access are considered to constitute readily accessible for this code change when conforming to the additional access requirements of the I Codes: (1) A permanent stair. (2) A pull-down stair with a minimum 300 lb. (136 kg) capacity. (3) An access door from an upper floor level. 8. The amendment of Article 500.8(A), entitled Suitability, to hereafter read as follows: (A) Suitability. Suitability of identified equipment shall be determined by one of the following: (1) Equipment listing or labeling; (2) Evidence of equipment evaluation from a qualified testing laboratory or inspection agency concerned with product evaluation; or, (3) Evidence acceptable to the authority having jurisdiction such as a manufacturer's self-evaluation or an engineering judgment signed and sealed by a qualified Registered licensed Professional Engineer in the State of Texas. Informational Note: Additional documentation for equipment may include certificates demonstrating compliance with applicable equipment standards, indicating special conditions of use, and other pertinent information. 9. The amendment of Article 505.7(A), entitled Implementation of Zone Classification System, to hereafter read as follows: (A) Implementation of Zone Classification System. Classification of areas, engineering and design, selection of equipment and wiring methods, installation, and inspection shall be performed by a Registered Professional Engineer licensed in the State of Texas. 10. The amendment of Article 695.6(A)(1), entitled Services and On-Site Power Production Facilities, to hereafter read as follows: (1) Services and On-Site Power Production Facilities. Service conductors and conductors supplied by on-site power production facilities shall be physically routed outside a building(s) and shall be installed as service-entrance conductors in accordance with 230.6, 230.9, and Parts III and IV of Article 230. Where supply conductors cannot be physically routed outside of buildings, the conductors shall be permitted to be routed through the building(s) where installed in accordance with 230.6(1) or (2). 11. The amendment of Article 710.15(A), entitled Supply Output, to hereafter read as follows: (A) Supply Output. Power supply to premises wiring systems fed by stand-alone or isolated microgrid power sources shall have adequate capacity to meet the calculated load in accordance with Article 220.
(Amend Ord 22-059, 11/01/22)
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.