§ 1001 — Definitions
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Uniform Housing Code Chapter, § 1001
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/dba2b707-a6e1-44d6-970a-ba8576f3cf85
Section 1001. Definitions
(a) General. Any building or portion thereof including any dwelling unit, guest room or suite of rooms, or the premises on which the same is located, in which there exists any of the following listed conditions to an extent that endangers the life, limb, health, property, safety or welfare of the public or the occupants thereof shall be deemed and hereby is declared to be a substandard building. (b) Inadequate Sanitation. Inadequate sanitation shall include but not be limited to the following: 1. Lack of or improper water closet, lavatory, bathtub or shower in a dwelling unit as described in Section 505. 2. Lack of or improper water closets, lavatories and bathtubs or showers per number of guests in a hotel as described in Section 505. 3. Lack of or improper kitchen sink as described in Section 505. 4. Lack of hot and cold running water to plumbing fixtures in a hotel as described in Section 505. 5. Lack of hot and cold running water to plumbing fixtures in a dwelling unit as described in Section 505. 6. Lack of adequate heating facilities as described in Section 701. 7. Lack of or improper operation of required ventilating equipment as described in Section 701. 8. Lack of minimum amounts of natural light and ventilation required by this code as described in Section 504. 9. Room and space dimensions less than required by this code as described in Section 503. 10. Lack of required electrical lighting as described in Section 701. 11. Dampness of habitable rooms as described in Section 601. 12. Infestation of insects, vermin or rodents as determined by the Health Officer. 13. General dilapidation or improper maintenance as described in Section 1001(1). 14. Lack of connection to required sewage disposal system as described in Section 1001(f). 15. Lack of adequate garbage and rubbish storage and removal facilities as determined by the Health Officer. 16. Furnished appliances (provided by the owner) in inoperative condition. (c) Structural Hazards. Structural hazards shall include but not be limited to the following: 1. Deteriorated or inadequate foundations. 2. Defective or deteriorated flooring or floor support. 3. Flooring or floor supports of insufficient size to carry imposed loads with safety. 4. Members of walls, partitions or other vertical supports that split, lean, list or buckle due to defective material or deterioration. 5. Members of walls, partitions or other vertical supports that are of insufficient size to carry imposed loads with safety. 6. Members of ceilings, roofs, ceiling and roof supports or other horizontal members which sag, split or buckle due to defective material or deterioration. 7. Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that are of insufficient size to carry imposed loads with safety. 8. Fireplaces or chimneys which list, bulge or settle due to defective material or deterioration. 9. Fireplaces or chimneys which are of insufficient size or strength to carry imposed loads with safety. (d) Nuisance. Any nuisance as defined in this code. (e) Hazardous Wiring. All wiring except that which conformed with all applicable laws in effect at the time of installation and which has been maintained in good condition and is being used in a safe manner. (f) Hazardous Plumbing. All plumbing except that which conformed with all applicable laws in effect at the time of installation and which has been maintained in good condition and which is free of cross connections and siphonage between fixtures. (g) Hazardous Mechanical Equipment. All mechanical equipment, including vents, except that which conformed with all applicable laws in effect at the time of installation and which has been maintained in good and safe condition. (h) Faulty Weather Protection, which shall include but not be limited to the following: 1. Deteriorated, crumbling or loose plaster. 2. Deterioration or ineffective waterproofing of exterior walls, roof, foundations or floors, including broken windows or doors. 3. Defective or lack of weather protection for exterior wall coverings, including lack of paint or weathering due to lack of paint or other approved protective covering. 4. Severely peeling, flaking or chipped paint. 5. Missing, broken, rotted, split, dilapidated or buckled exterior wall coverings, roof coverings or garage doors. (i) Fire Hazard. Any building or portion thereof, device, apparatus, equipment, combustible waste or vegetation which in the opinion of the Chief of the Fire Department would augment the spread and intensity of fire or explosion arising from any cause. (j) Faulty Materials of Construction. All materials of construction except those which are specifically allowed or approved by this code and the Building Code and which have been adequately maintained in good and safe condition. (k) Hazardous or Unsanitary Premises. Those premises on which an accumulation of weeds, vegetation, junk, dead organic matter, debris, garbage, offal, rate harborages, stagnant water, combustible materials and similar materials or conditions constitute fire, health or safety hazards. (l) Inadequate Maintenance. Any building or portion thereof which is determined to be an unsafe building in accordance with the Building Code. (m) Inadequate Exits. All exits which do not meet the requirements of this code except those which conform with all applicable laws at the time of their construction and which have been adequately maintained and increased in relation to any increase in occupant load, alteration or addition or any change in occupancy. Lack of adequate exits shall exist when there is not at least one (1) bedroom window per bedroom below the fourth (4th) story capable of being opened to the maximum size intended. When an unsafe condition exists through lack of or improper location of exits, additional exits may be required to be installed. (n) Inadequate Fire Protection or Fire Fighting Equipment. All buildings or portions thereof which are not provided with the fire resistive construction or fire extinguishing systems or equipment required by this code, except those buildings or portions thereof which conformed with all applicable laws at the time of their construction and whose fire resistive integrity and fire extinguishing systems or equipment have been adequately maintained and improved in relation to any increase in occupant load, alteration or addition or any change in occupancy. (o) Improper Occupancy. All buildings or portions thereof occupied for living, sleeping, cooking or dining purposes which were not designed or intended to be used for such occupancies. (p) Air Conditioning Equipment. Where air conditioning is furnished to the occupant of a rental unit, failure to design to a twenty (20) degree difference between inside and outside temperatures and to function to at least a fifteen (15) degree difference.
(Amend Ord 00-059, 5/16/00) (Amend Ord 04- 009, 1/13/04)
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.
