For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.05 — Design and Construction Requirements for Piers and Boathouses

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Construction Chapter, § 19.05

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/03b7beb5-3f37-4405-82c1-0de2c1307ba3

Section 19.05 Design and Construction Requirements for Piers and Boathouses

A. All piers and boathouse in Lake Arlington shall be considered accessory structures. A primary structure must be present on the lot to which a pier, boathouse and/or walkway is erected or constructed. B. All piers and boathouses must be designed and sealed by a licensed professional engineer. The following specific criteria must be incorporated in the engineer’s design and be included on the construction documents: 1. All piers and/or boathouses shall be designed to withstand the loads as specified in the Building Code, 2. All piers and/or boathouses shall be designed to withstand a minimum of four foot high wave action and the design wind load simultaneously; 3. Designs shall include the impacts of wind and wave action effects of boats attached to the pier and/or boathouse. 4. Floating piers and boathouses shall be designed with anchorage footing and piers to remain in place to prevent the structure from floating or rising above the 100-year flood elevation; 5. Cables and chains used in anchoring systems shall be designed with a minimum working load safety factor of 3.0 for cables and 2.0 for chains; 6. Flotation devices for boathouses, walkways and bridges shall be designed and/or manufactured to support the dead load and live load as a fixed structure. C. Building zone width. The building zone width is determined by the extension of the side property lines of a lot into the lake less the required minimum side setback. Minimum side setbacks for piers and boathouses from the extended side property lines are as set forth in Table 19B - Buildable Zone Width. See Figure 19A - Buildable Zone Width for illustration purposes. Table 19B - Buildable Zone Width LOT WIDTH | MIN SIDE SET BACK Less than 50 feet | 5 feet 50 feet to 69 feet | 10 feet 70 feet to 99 feet | 15 feet 100 feet or more | 20 feet [image omitted; see the official code] Figure 19A - Buildable Zone Width Illustration D. Maximum structure area. The maximum horizontal area of structures incidental to a single property (piers and/or boathouses) is 1,000 square feet. EXCEPTION: For property owners that remove existing retaining walls and provide shoreline restoration; or, for property owners that elect to preserve existing natural shoreline areas, the maximum area of structures may be 1,250 square feet. Shoreline Restoration and Preservation projects must comply with the Lake Arlington Chapter. E. Maximum length into the Lake. Piers and/or boathouses shall not extend into the lake more than 100 feet from the shoreline. EXCEPTIONS: 1. If the elevation of the Lake bottom at the 100 foot limit is higher than 545 feet above mean sea level then the dock may extend to the point where the Lake bottom is 545 feet above mean sea level to a maximum length of 150 feet as measured from the shoreline regardless of Lake Bottom elevation. This exception may not apply in narrow areas of the reservoir. 2. In narrow areas of the reservoir (See figure 19B - Map of Narrow Areas), no structure shall occupy more than one third (1/3) of the channel width and in no case shall a structure extend out into the reservoir to a point that is more than 20 feet from the centerline of the channel. For the purposes of this provision, the channel width is measured from water’s edge at the normal lake elevation of 548 feet mean sea level. See Figure 19C - Narrow Channel Illustration. 3. For property owners that remove existing retaining walls to undergo a shoreline restoration effort; or, for property owners that elect to preserve existing natural shoreline areas the maximum length of a pier may be extended to 125 feet. This exception may not apply in narrow areas of the reservoir. [image omitted; see the official code] Figure 19B - Map of Narrow Areas [image omitted; see the official code] Figure 19C - Narrow Channel Illustration F. All piers and boathouses shall have lights in accordance with this subsection. These requirements apply to any piers and boathouses that extend into the Lake more than eight feet from a shoreline measured perpendicular to the shoreline. 1. Piers and boathouses must be continuously lighted with amber lights between sunset and sunrise each day. 2. Piers and boathouses must have at least one light station. Except as otherwise provided in this subsection, the light station must be located on the end of the pier and/or boathouse and on the side that is farthest from and parallel to the shoreline. The light must be visible to a properly approaching watercraft. 3. A pier or boathouse that extend thirty feet or more from the shoreline must have at least one light station on each side of the pier and/or boathouse not facing the shoreline. 4. A pier or boathouse that extends fifty feet or more from the shoreline must have light stations from the shoreline to the end of the pier and/or boathouse at intervals of not more than twenty five feet except that a light station may not be located within eight feet of the shoreline. 5. Each light station required by this subsection must have a two-bulb fixture with two working light bulbs between 7.5 and 25 watts. Light bulbs or covers must be amber and white light shall not radiate from the fixture. Light stations must be controlled by only a photoelectric cell to insure dusk to dawn continuous operation. 6. All electrical wiring on any pier and/or boathouse shall be in accordance with the City of Arlington electrical code for marine applications. 7. Other lights installed that are not required by this subsection may only cast light down and shall not cast light outward from the pier. 8. Any pier and/or boathouse that require lights under this subsection shall provide temporary lighting during construction and until the permanent lighting is installed. G. Address. Each pier and/or boathouse shall have an address placard stating the street address and the street name of the primary residence associated with the structure. The address placard shall be clearly legible from the lake side of the structure. The lettering shall be a minimum of 6-inch high and be made of reflective material so that the address can be read at night. Placards shall be made of cast aluminum and be rectangular in shape. H. Toilet. Toilet facilities of any type are prohibited on any boathouse or pier. I. Water. The installation of a potable water line shall comply with the plumbing code. J. Electrical. The installation of any electrical components shall comply with the electrical code. K. Specific design requirements for boathouses. 1. Single Story. All boathouses are limited to a single story (lower deck) and a sundeck (upper deck) or roof. 2. Height. The maximum height of any boathouse is thirteen feet as measured vertically from the pier walking surface to the top plate line. 3. Pitch. The maximum pitch for any sloped roof is 3:12. 4. Roofs. Flat roofs shall have a minimum roof pitch of 1/2:12. The upper flat roof may be constructed for use as a sundeck. When the upper deck is utilized as a sundeck, the following regulations apply: a. The sundeck may not have a permanent roof or covering. b. The sundeck is accessible by stairway and handrails constructed in accordance with the building code. c. The sundeck area is protected with a surrounding guardrail constructed in accordance with the building code. d. Except for the required guardrails, no other vertical construction is permitted on the upper deck. 5. Enclosed boathouses are prohibited. Solid sides on the boathouse are permitted at a maximum of two feet downward from the top plate. No additional materials (i.e. lattice, fencing, bars, screen fabric, doors, glass, etc.) may be installed below the two foot sidewalls. 6. A single enclosed storage area is permitted only on the lower deck of a boathouse. The enclosed storage area may only be used for the purpose of storing items such as fishing tackle, skis and life jackets. Products considered hazardous material or any material which has a warning label prohibiting its use or storage near water and/or public water supplies is prohibited. The maximum area allowed for the enclosed storage shall be 32 square feet. L. Design criteria for piers and/or boathouses. 1. The use of wood piles is prohibited; 2. Metal piles shall be a minimum of three inches inside diameter schedule 40 pipe. Such piles shall be driven by a pile hammer to a point of resistance. Such piles shall be driven in pairs, one on either side of the structure and braced. Such piles shall be spaced a maximum of twelve feet center to center. 3. Flotation structures shall be anchored with solid units that will provide the following anchorage: a. All anchors shall be of masonry, concrete, or steel and shall be securely fastened to the pier or boathouse by cable, chain, or other approved methods. b. All piers and boathouses shall be anchored to the shore line. c. Piers less than fifty feet in length shall be anchored on each corner designed to support one-fourth of the total dead load plus one-eighth the total live load. d. Piers fifty feet or more in length shall also be anchored at the midpoint of the pier. 4. Required Water Proofing: All wood below the 100-year flood elevation shall be approved pressure-preservative-treated wood as defined in the building code. All metal, including bolts, lag bolts, and fasteners, shall be galvanized or factory painted and listed for immersion in water. Creosote treated wood is prohibited. 5. Floating structures and flotation. Flotation material shall be extruded polystyrene, expanded polystyrene, or a copolymer of polyethylene and polystyrene and have the following characteristics: a. A minimum density of 0.9 pounds per cubic foot and be of consistent quality throughout the float. b. Beads shall be firmly fused together with no voids inside the encasement. c. Flotation material shall have a water absorption rate of less than 3.0 pounds per cubic foot over seven days when tested by the Hunt Absorption Test. d. All flotation material shall be encased in solid polyethylene or a polyurethane type coating, both of which shall be watertight and have a nominal thickness of 0.125 inches. e. Drums made of plastic or metal, whether new or recycled, are prohibited from use as an encasement or float. f. All floats shall be warranted for a minimum of fifteen (15) years against sinking, becoming waterlogged, cracking, peeling, fragmenting, or losing beads, and shall not be prone to damage by animals. M. Shoreline Restoration and Preservation. Shoreline Restoration and Preservation shall be conducted as provided for in the Lake Arlington Chapter.

(Amend Ord 12-011, 4/3/12) (Amend Ord 11-043, 8/16/11)

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.