§ 2.09 — Grease, Oil, and Sand Interceptors Required
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Industrial Waste and Water Pollution Control Chapter, § 2.09
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/880105dc-814d-40cc-85b3-69b6d656e333
Section 2.09 Grease, Oil, and Sand Interceptors Required
Where any wastewater contains or may contain sand, grit, debris, undesirable wastes or oil and grease in excess of the allowable limit, appropriate interceptors to remove the aforementioned substances shall be provided and maintained by the User at his own expense and as required by the Authority. Such Users shall: 1. Direct all waste streams, which contain or may contain sand, grit, debris, undesirable wastes or oil and grease in excess of the allowable limit into an approved interceptor or other pretreatment device approved by the Authority. a. All fixtures, equipment and drain lines located in a facility’s food preparation and clean up areas shall be connected to an appropriately sized grease interceptor. b. The types of equipment or fixtures that shall be connected to a grease interceptor include, but are not limited to the following: pre-rinse or pre-wash sinks or sinks in dishwashing areas; dishwashers; two or three compartment sinks; wok stoves; garbage disposals; kitchen floor drains; floor sinks; mop sinks; food prep sinks and hand sinks. 2. Provide equipment and facilities of a type, design and minimum capacity approved by the Authority. a. Interceptors designed to remove oil and grease shall: (1) have a minimum of two compartments. (2) conform to City of Arlington specifications. (3) separate and retain grease and store settled solids. (4) be constructed and installed for adequate load bearing capacity. (5) have a manhole cover of at least 24 inches (24") in diameter to accommodate cleaning, maintenance, personnel entry, and in accordance with Chapter 30 of the Texas Administrative Code or City of Arlington specifications, at level grade, over each compartment of the interceptor. (a) Bricks or any other un-approved device shall not be used to raise a manhole cover to grade or to secure the manhole cover to the interceptor. (b) Manhole covers shall be installed in a manner that will prevent inflow and infiltration. (6) be installed in a location outside of the building and shall not be placed in such a proximity to the facility that would cause any type of nuisance. (7) be size based on the Plumbing Code as adopted by the City or as determined by the Authority. b. Interceptors designed to remove sand and grit shall: (1) separate and retain sand and grit, and store settled solids. (2) be constructed and installed for adequate load bearing capacity. (3) have a manhole cover of at least 24 inches (24") in diameter to accommodate cleaning, maintenance, personnel entry, and in accordance with Chapter 30 of the Texas Administrative Code or City of Arlington specifications, at level grade, over each compartment of the interceptor. (a) Bricks or any other un-approved device shall not be used to raise a manhole cover to grade or to secure the manhole cover to the interceptor. (b) Manhole covers shall be installed in a manner that will prevent inflow and infiltration. (4) not be installed in a location or manner that would cause any type of nuisance. (5) be sized based on the Plumbing Code as adopted by the City or as determined by the Authority.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.