For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3-200 — Off-Street Parking Standards

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Major Sports Complex Chapter, § 3-200

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/3a265054-3906-493c-aeae-71602e68ec1e

Section 3-200 Off-Street Parking Standards

A. Location 1. It is not necessary that required off-street parking for each use be located on the same lot or tract occupied by such use. 2. No off-street parking or loading space shall be located, either in whole or in part, within any fire lane required by ordinance of the City or within aisles, driveways or maneuvering areas necessary to provide reasonable access to any parking space within an off-street parking facility. B. Minimum Off-Street Parking Required 1. The minimum amount of off-street parking shall be calculated in accordance with Table 5.4-1, Off-Street Parking Schedule A, of the “Unified Development Code” Chapter of the Code of the City of Arlington. 2. Where a major sports complex or approved venue project is used for a combination of uses, the minimum amount of off-street parking required shall be the composite or sum of the requirements for each type of use, provided that such sum shall be reduced based on the method prescribed by Section 5.4.4(B), of the “Unified Development Code” Chapter of the Code of the City of Arlington. 3. In determining the required number of parking spaces, fractional spaces shall be counted to the nearest whole space. 4. Parking spaces located in drive-through lanes shall not be counted as meeting the required minimum parking. 5. The floor area of structures devoted to off-street parking of vehicles shall be excluded in computing the floor area for off-street parking requirements. 6. Parking required under this Section may be satisfied by any parking spaces that the person or entity holding or owning (whether directly or indirectly), from time to time, the legal possessory right or interest to the lot or tract occupied by such use has the right to use, provided such parking is located at any parking facility within the same zoning district as such use. 7. Provided none of the uses sharing a parking facility require the same parking space at the same time, each use shall be deemed to have provided such parking individually for purposes of satisfying the requirements of this Section. 8. No parking located within any publicly dedicated right-of-way shall count toward the number of off-street spaces required under this Section. C. Construction Design Standards 1. Pavement. An all-weather surface parking facility shall be constructed of asphalt or concrete. The Zoning Administrator may approve the use of a porous paving system or other pervious surface. 2. Spaces. No parking space shall be less than eighteen (18) feet in length and nine (9) feet in width. Exception: Parking spaces may be reduced in length when a tire-stop curb is installed sixteen (16) feet from the maneuvering lane and a clear space of two feet is provided for a vehicle to overhang. The overhang is not permitted over public property, any sidewalks, or a setback in which parking is not permitted. Such reduction is permitted only when the width of the maneuvering lane is maintained at twenty-six (26) feet. 3. Markings. Parking spaces shall be striped or otherwise clearly designated on the parking facility surface, and shall not include any fire lane or other area necessary for aisles or maneuvering of vehicles. 4. Lighting. Parking lots shall have exterior lighting in all publicly accessible areas. Such lighting need not be operated on non-event days. All such lighting shall be controlled by a photo cell or seasonally-adjusted timer switch. Light intensity shall be a minimum of 0.4 foot candle power. The light intensity value shall not represent the initial illumination of a light, but shall represent the maximum level of acceptable darkness in any publicly accessible area when measured at a height not greater than three (3) feet from the ground. Lighting fixtures that have been identified as non-operable shall be repaired to an operable state within seventy-two (72) hours. D. Parking for the Disabled. Required parking spaces for the disabled shall be provided for all uses in accordance with Americans with Disabilities Act and the Texas Accessibility Standards. E. Maintenance. Parking facilities and loading berths shall be maintained and kept in a state of good repair at all times by the owner or the person in control of the premises. F. Use. Any parking facility within a major sports complex or as part of an approved venue project may contain, as an accessory use, any use permitted by the “Unified Development Code” Chapter of the Code of the City of Arlington within the zoning district in which such parking facility is located.

(Amend Ord 15-019, 5/26/15)

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.