§ 4.1 — Measurements and Exceptions

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 4.1

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/638b6f42-3433-4bad-a873-f4b12ffdd805

4.1. MEASUREMENTS AND EXCEPTIONS

4.1.1. DENSITY A. Gross Density Gross density is the number of principal dwelling units allowed for each gross acre of land, and is determined by dividing the number of dwelling units on a site by the gross acreage of the site, including dedicated rights-of-way, private streets, and open space set asides, but excluding perimeter right-of-way dedicated for streets. In the determination of the number of principal residential units to be allowed on a specific parcel of land, a fractional unit equal to or greater than one-half of a unit shall be rounded up to equal a full unit. The density calculation does not include secondary residential units. B. Dwelling Units Allowed The number of dwelling units allowed on a site is based on the presumption that all other applicable standards of this Code shall be met. The maximum density established for a zoning district is not a guarantee that such densities may be obtained, nor a valid justification for varying or modifying other dimensional or development standards. 4.1.2. LOT AREA A. Lot area shall mean the total gross lot area unless otherwise indicated. B. Existing platted lots shall not be made nonconforming by the acquisition of public right-of-way. See Article 11, Nonconformities. C. Transit passenger shelters are exempt from the minimum lot area requirements. 4.1.3. GROSS LIVING AREA A. The minimum required gross living area for a multifamily dwelling unit is calculated exclusive of breezeways, garages, porches, carports, and balconies. B. In the RE, RS-20, RS-15, RS-7.2, and RS-5 zoning districts, the Zoning Administrator may reduce the minimum gross living area to 1,000 square feet where a smaller unit size is consistent with existing development in surrounding neighborhoods. 4.1.4. LOT COVERAGE A. Lot coverage shall mean the percentage of a lot covered by primary and accessory buildings. Paving for parking facilities is not counted when calculating lot coverage. B. For single-family uses in the RE, RS-20, RS-15, RS-7.2, RS-5, RM-12, VG and PD zoning districts, maximum lot coverage calculations shall not include paving, swimming pools, decks, and uncovered patios unless otherwise indicated. C. Lots smaller than 7,500 square feet in mixed-use districts shall have minimum building footprint coverage of 60 percent. 4.1.5. MINIMUM LOT WIDTH A. In addition to the minimum lot width requirements, corner lots for one- or two-family residential uses located in residential districts and PD-zoned property that have a side lot line abutting an arterial street, shall provide an additional 20 feet in lot width to allow appropriate building setbacks from and orientation to all arterial streets. B. All other corner lots for residential use shall provide an additional ten feet of lot width over the minimum standards. C. Lots for one- or two-family residential uses located in in residential districts and PD zoned property that have direct access on to a major collector shall have a minimum lot width of 120 feet. 4.1.6. SETBACKS A. Definitions 1. A street frontage setback is that area extending along any front, side, or rear lot line that is adjacent to a street, private access easement, or alley in which no structure may be built. 2. The side interior building setback is that area extending along the side lot line not adjacent to a street, private access easement, or alley in which no structure may be built. 3. The rear building setback is that area extending across the rear lot line, not adjacent to a street, private access easement, or alley, in which no structure may be built. B. Platted Building Lines and Setbacks Setbacks shall conform to the setback requirements of the applicable zone district regardless of previously approved platted building lines or setbacks. C. Measurement Setbacks shall be measured from the property lines, except as follows: 1. Street frontage setbacks shall be measured from the right-of-way line as shown on the Thoroughfare Development Plan for arterial and collector streets, as shown in Figure 4.1 below. 2. Street frontage setbacks shall be measured from the existing right-of-way for all non-Thoroughfare Development Plan streets, as shown in Figure 4.1 below. [image omitted; see the official code] Figure 4.1 Setback measurement at thoroughfare right-of-way 3. Street frontage on private access easements or alleys shall be measured from the closest edge of a private access easement or alley for residential zoning districts. D. Double-Frontage Lots Except in the mixed-use zoning districts, street setbacks shall be required on all frontages of double-frontage lots. In the mixed-use zoning districts, the street setback shall be required only in the front yard of the primary structure. E. Corner Lots 1. For corner lots, only one lot line shall be considered the front lot line. The front setback shall be measured from the front lot line. 2. The Zoning Administrator may determine the front yard to be on the street front that is consistent with the prevailing pattern of front yards on the street in order to maintain compatibility with the established development pattern of the street. F. Standards 1. Setbacks shall be unoccupied and unobstructed by any building, structure, or portion of a structure from 30 inches above grade upward; provided, however, that fences, non-structural walls, trellises, poles, posts, ornaments, furniture, and other customary yard accessories may be permitted in any setback subject to height limitations and visibility triangle requirements of this Code. 2. As used in this section, the term “building” includes any structure that by nature of its size, scale, bulk, dimension, or use constitutes a visual obstruction or generates activity similar to that usually associated with a building. Without limiting the generality of the foregoing, the following structures shall be deemed to fall within this description: a. Gas pumps and overhead canopies or roofs. b. Fences running along lot boundaries adjacent to public rights-of-way that exceed six feet in height and are substantially opaque. 3. Landscaping that meets or exceeds the requirements in Section 5.2, Landscaping, is permitted in any setback or transitional buffer yard. G. Minimum Setback Reductions The following setback reductions apply to the minimum setbacks as indicated below: 1. In the RE, RS-20, RS-15, RS-7.2, RS-5, VG, and RM-12 zoning districts, covered front porches and j-swing garages may encroach up to five feet into the 20-foot setback from a local street, private access easement, or alley. This reduction shall not apply to front entry garages. 2. For permitted townhouses and duplexes, the minimum front setback may be reduced to fifteen feet when access is provided by a private access easement at the rear of the structure and the lot fronts a minor collector, local street, or private access easement. 3. The side setback for an attached townhouse may be reduced to zero except for end units, which shall have a minimum side setback of five feet. 4. When a single family or townhouse residence is developed on a double-frontage lot with a minor arterial or local street as the rear lot line, and a fence is installed as permitted by Section 5.3.4, Fences, then the rear setback for the residence and accessory structures may be reduced to five feet. If the double-frontage lot backs up to a major thoroughfare, the rear setback for accessory structures may be reduced to five feet or the setback required by 3.3.6.A., whichever is greater. H. Permitted Projections into Required Setbacks Structures listed in this subsection may project into specified required setbacks. Projections shall not extend or encroach into a public or private easement or right-of-way, nor obscure a required visibility triangle as described in Section 5.3.5, Visibility Triangles Maintained. 1. Uncovered Paved Terraces and Patios Uncovered paved terraces and patios not taller than 12 inches may project into any required setback, provided that no structures placed there shall violate other requirements of this Code. 2. Unroofed Landings, Decks, Stairs, and Balconies Unroofed landings, decks, and stairs may project into required setbacks not more than 5 feet, provided that no portion other than a handrail shall extend higher than 30 inches above the finished grade level. Unroofed balconies may project into a required side or rear yard provided that these projections are at least five feet from the property line. 3. Incidental Architectural Features Cornices, eaves, canopies, sunshades, gutters, chimneys, flues, belt courses, headers, sills, pilasters, lintels, ornamental features, box windows, and other similar architectural features may project not more than two feet into any required yard provided these projections occupy not more than two percent of the required setback area and are at least five feet from the lot line. 4. Roofs Over Porches and Other Exterior Approaches Roofs over porches, stairways, landings, terraces, or other exterior approaches to pedestrian doorways may encroach up to five feet into a front setback. The covered porch or entrance area encroaching into the setback shall remain exterior to the building and enclosed by no more than a railing. 5. Handicap Ramps Handicap access ramps may be located within required front, side, and rear setbacks. 6. Fences Fences as regulated by Section 5.3.4, Fences. 7. Parking Facilities Parking facilities and structures as regulated by Section 5.4, Off-Street Parking and Loading. 8. Swimming Pools A swimming pool, and the decking around a swimming pool, may project into the required side or rear setback, provided the outside wall of the pool is at least five feet from the lot line. 4.1.7. BUILDING HEIGHT A. Measurement of Primary Structures The height of a building shall be the vertical distance measured from the average elevation of the finished grade along the front of the building to the highest point of the roof surface of a flat roof; to the deck line of a mansard roof; and to the mean height level between eaves and ridge for a gable, hip, or gambrel roof. B. Measurement of Accessory Structures For all accessory structures, the height of a building is measured as the height of the tallest wall. C. Height Exceptions for Appurtenances Except as specifically provided elsewhere in this Code, the height limitations contained in this Code do not apply to cupolas, flagpoles, chimneys, antennas, heating and ventilation equipment, stairwell towers, lightning rods, ground-mounted wind turbines, solar panels, or similar appurtenances; provided, however, the following: 1. The appurtenance does not interfere with Federal Aviation Regulations; 2. The appurtenance does not extend more than five feet above the maximum permitted building height, except for flagpoles, belfries, and antennas that must be of greater height in order to function; 3. The appurtenance is not constructed for the purpose of providing additional floor area in the building; 4. The appurtenance complies with the screening requirements for mechanical equipment and appurtenances in Section 5.3.2, Mechanical and Utility Equipment Screening; and 5. The appurtenance is functional. D. Special Height Limitations in Airport Controlled Area Building height may be further limited within the APO overlay district. E. Special Height Limitations in Non-Residential Zoning Districts For all buildings contained within a non-residential zoning district, except within the Limited Office (LO) zoning district, the following height standards shall apply. 1. There shall be no height limitation, unless otherwise provided within an Overlay District; except a. A building’s height shall not exceed 45 feet within the first 75 feet of a shared property line with an existing single-family residential zoning or use; and b. A building’s height shall not exceed a height of one foot for every one foot of distance from the existing single-family residential zoning or use shared property line. 2. Multi-family and mixed-use residential buildings located within any non-residential zoning district must also meet a minimum height of six (6) stories when adjacent to major thoroughfares, freeways, and highways within the first 100 feet of the right-of-way.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.