For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.07 — Water Quality Monitoring Requirements including Total Maximum Daily Loads (TMDLs)

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Stormwater Pollution Control Chapter, § 5.07

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/327147b7-669f-4bd3-8192-17c2248eb56c

Section 5.07 Water Quality Monitoring Requirements including Total Maximum Daily Loads (TMDLs)

A. The permittee shall monitor discharges from the facility at all outfall(s) determined to be discharging a pollutant of concern at a level of concern under Part II, Section B.7, Impaired Water Bodies and Total Maximum Daily Load (TMDL) Requirements of the TPDES MSGP. B. The permittee may not establish substantially similar outfalls for sampling required by the MSGP. C. The permittee shall monitor the discharge(s) from regulated industrial activities for the pollutant of concern at a frequency of once per year. For the following pollutants of concern, monitoring must be conducted for the following alternative pollutants, unless an alternate is approved in writing by the EPA or TCEQ, or the TCEQ develops separate written guidance: Pollutant(s) of Concern: Bacteria: E.coli (for discharge to fresh water); or enterococci (for discharges to marine waters). 5.07 Dissolved Oxygen: BOD5, COD, or both (based on the nature of the industrial activity, and whether there is an existing benchmark sampling requirement for the facility’s industrial sector). Nutrients: Phosphorous (for discharges to fresh water); or Nitrogen (for discharges to marine waters), unless otherwise established in an applicable TMDL or TMDL Implementation Plan. Hazardous Metals: Specific metal(s) listed in 303d list or the TMDL. Other: If the impairment is due to a parameter for which there is not an obvious analytical test or benchmark value (e.g., sediment, fish tissue, etc.), the permittee shall contact the TCEQ for guidance on which pollutant(s) to monitor for, if any, and the TCEQ will respond in writing. The permittee shall retain this information with the SWP3. The permittee may utilize the analytical results of sampling for other sections of this general permit to comply with this annual sampling requirements (e.g., hazardous metals sampling in Part III, Section C, or benchmark monitoring in Parts IV and V of this general permit). D. Sampling, monitoring, and analyses must be conducted according to procedures specified in Part III, Section E.4 of the TPDES MSGP unless otherwise specified and using test procedures with minimum analytical levels (MALs) at or below benchmark values for all the benchmark parameters for which sampling is required. E. Reporting: The permittee shall report the result of sampling for this section to the TCEQ by March 31 following the calendar year in which the samples were collected. Results must also be submitted to the City of Arlington. F. If sampling results indicate that the pollutant is present below the level of concern (e.g., the analytical result is below the benchmark values outlined in the TPDES MSGP) or is not present (e.g., analytical result is below the MAL), then the permittee may discontinue sampling under this section for the remainder of the permit term.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.