Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Mobile Homes and Travel Trailers Chapter, § 8.06

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/c50fbc66-96fa-4f6d-8385-b71f0d37ad2c

Section 8.06 Electrical Distribution System

A. General Requirements - Every park shall contain an electrical wiring system consisting of wiring, fixtures, equipment and appurtenances which shall be installed and maintained in accordance with applicable codes and regulations governing such systems. B. Power Distribution Lines 1. Main power lines located above ground shall be suspended at least eighteen (18) feet above ground level. There shall be a minimum horizontal clearance of three (3) feet between overhead wiring and any trailer, service building or other structure. 2. All direct burial conductors or cable shall be buried at least eighteen (18) inches below the ground surface and shall be insulated and specially designed for the purpose. Such conductors shall be located not less than one foot radial distance from water, sewer, gas or communication lines. C. Individual Electrical Connections 1. Where individual electrical connections are provided at trailer spaces, they shall include an approved disconnecting device and over-current protective equipment. The minimum service per outlet shall be 120 volts AC, 50 amperes. 2. Outlets (receptacles or pressure connectors) shall be housed in a weatherproof outlet box, and shall be located not more than 25 feet from the over-current protective device in the trailer. A three-pole, four-wire grounding type shall be used. 3. Receptacles, if provided, shall be in accordance with American Standard Outlet Receptacle C-73.1. 4. Connectors, if not substituted by more than one receptacle, shall be provided where the calculated load of the trailer is more than 50 amperes. 5. The trailer shall be connected to the outlet box by an approved type of flexible supply cord with a male attachment plug or with pressure connectors. D. Required Grounding - All exposed non-current carrying metal parts of travel trailers and all other equipment shall be grounded by means of an approved grounding conductor with branch circuit conductors or other approved method of grounded metallic wiring. The neutral conductor shall not be used as an equipment ground for travel trailers or other equipment.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.