§ 15-1-11 — CROSS-CONNECTIONS PROHIBITED
Austin City Code (Supp. No. 174: codified through Ordinance No. 20260521-050, effective June 1, 2026) · Austin City Code § 15-1-11
Corpus is an independent public-information project, not the official City of Austin website. Stable reference: corpuslaw.us/code/07371907-5190-4376-83a7-b8d5755e73dc
§ 15-1-11 - CROSS-CONNECTIONS PROHIBITED.
(A) A person shall not: (1) install, maintain, or allow to exist a potable water supply, plumbing fixture, equipment, mechanism, or construction device that creates a cross-connection, or allows reclaimed, contaminated, or polluted water, mixtures or other substances, or gases, to enter the private or public potable water system by backsiphonage, backpressure, or other means; (2) connect an alternate water supply to the City's public water system or a private plumbing system unless a backflow prevention assembly or air gap is installed as required by this chapter; (3) use a chemical or substance that may cause pollution or contamination of the public or private potable water system without installing a backflow prevention assembly or backflow prevention device as required by this chapter; (4) connect a reclaimed water system to the City's public water system or to the potable water system of a customer who receives potable water service from the City's public water system; or (5) connect a vehicle or equipment capable of producing backsiphonage or backpressure without installing a backflow prevention assembly or device as required by this chapter. (B) A person shall not install a backflow prevention assembly in a private plumbing system, fire protection system, process water system, irrigation system, or other water distribution system connected to the City's public water system unless: (1) the assembly complies with Table 15-1-14-A; (2) the assembly has been tested and listed as an approved backflow prevention assembly by the most recent listing from the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research; and (3) the installation complies with this chapter and the Plumbing Code. (C) A person shall not install a backflow prevention device unless the installation complies with this chapter and the Plumbing Code. (D) A person shall not connect the public water system or a plumbing system to any other source of potable or non-potable water without approval by the director. (E) The director may not install or authorize the installation of a permanent water or reclaimed water meter unless the customer's tester has submitted a test and maintenance report for each backflow prevention assembly installed on a site and all inspections are final as required by the Building Code. (F) A person shall not use a backflow prevention assembly or backflow prevention device unless: (1) the backflow prevention assembly or backflow prevention device was lawfully installed before April 21, 2025; (2) the use, maintenance, or repair of the backflow prevention assembly or device is in accordance with the original design and location; and (3) no hazard to life, health, or property has been created by such installation.
Source: Ord. No. 20250410-002, Pt. 1, 4-21-25.
Ask a question about Austin law
Corpus searches the Austin sections it holds and shows the ones that match, with their citations. Free, no sign-in.