§ 12.08.006: Noise measurement.

(a) Any noise measurement made pursuant to the provisions of this article shall be made with a sound level meter which meets the American National Standards Institute’s standard. The A-weighted network (scale) at “slow” response shall be used to measure the sound level. (b) No external measurements shall be made during precipitation or if the wind speed exceeds 15 miles per hour. (c) Exterior noise levels shall be measured at the property line of an offended person. Where practical, the microphone shall be positioned four to five feet above the ground and ten feet or more away from any reflective surface. For the purpose of enforcing this article, a measurement period shall be taken over a period of at least 10 minutes. (d) Interior noise levels shall be measured at a point at least four feet from any wall, ceiling or floor.

( Ordinance 11-025 , sec. 1, adopted 3/8/11 )