§ 22.02.104: Responsibilities of generator.

(a) A generator shall provide grease traps or grit traps when, in the opinion of the water quality manager, they are necessary for the proper handling of wastewater. Appeals of the decision of the water quality manager shall be handled as provided for other appeals under section 22.02.106(c) hereof. (b) Grease and grit traps shall be constructed to prevent fats, oils, or greases from entering the sanitary sewer in concentrations greater than 200 mg/l and shall be located so that they are easily accessible for cleaning, maintenance, and inspection. The installation of grease traps or grit traps shall comply with the requirements of the city’s plumbing code. (c) A generator shall properly install a sample port or sample well for ease in sampling the wastewater discharge from the grease or grit trap. Sample ports shall meet the following criteria: (1) The sample port shall be installed and maintained at the generator’s expense; (2) The sample port shall be installed as close as possible to the connection to the city sanitary sewer main within the bounds of the facility property; (3) The port shall be installed according to the specifications obtained from city water utilities. It shall be installed perpendicular to the effluent flow to allow visual observation and sampling; (4) The port shall be accessible for monitoring authorities; (5) New facilities being constructed shall have the sample port installed before opening for business. Established generators must install a sample port within six (6) months of approval of this division; (6) Exempt establishments may be required to install a sample port for inspection purposes. (d) A generator of grease trap or grit trap waste shall have the trap serviced as frequently as necessary to prevent bypass or overflow, and to insure proper operation of the trap. Such generators, at a minimum, shall have the grease or grit trap cleaned once every three (3) months. (e) If the city determines that quarterly cleaning of a grease or grit trap is not sufficient to prevent the discharge of oil and grease in quantities less than 200 mg/l, the city will require more frequent cleaning of the grease trap. (f) A manifest shall be generated every time the grease or grit trap is pumped or cleaned. The generator shall sign a copy of the manifest as well as the driver. It shall be the responsibility of the generator to insure they receive a copy of the manifest from the hauler after the grease or grit trap has been cleaned and that they receive a final copy of the manifest after the waste has been disposed of at the final disposal site and the disposal facility has signed the manifest. A copy of the completed manifest shall be sent to city water utilities every time the facility’s grease or grit trap is serviced. The manifest must be submitted within twenty-one (21) days of the servicing of the trap. (g) The generator shall keep copies of the completed grease or grit trap waste manifests for three (3) years. (h) A generator shall have his trap serviced by a transporter having a valid registration with the state. (i) Grease and grit traps shall be inspected for seepage into the surrounding media whenever the trap has been pumped. The generator shall repair, replace, or install apparatus and equipment as necessary to ensure the proper operation and function of the trap. (j) A generator shall supervise the servicing of their grease or grit traps and shall ensure they are completely emptied by the transporter during such servicing. The transporter shall not return any material to the grease or grit trap once the trap has been cleaned. (k) A generator shall clean up or cause to be cleaned up all spills of liquid or solid waste and shall have the waste properly disposed of by the transporter. (l) A generator that is located in a multi-user building may be required to separate sanitary sewer flows from adjacent sites and install a water submeter to measure individual water consumption or utilize some other method approved by the water quality manager or his designee. (m) The cost of complying with all sections of this division shall be the responsibility of the property owner and their lessees. These costs include but are not limited to any maintenance, analysis, grease or grit trap cleaning, repair, replacement, or modification, and installation of sample wells or ports.

( Ordinance 01-042 , sec. 1, adopted 6/12/01 ; 1978 Code, sec. 28-58(d) ; Ordinance 08-040 , sec. 29, adopted 5/13/08 )

Ask a question about Beaumont law

Corpus searches the Beaumont sections it holds and shows the ones that match, with their citations. Free, no sign-in.