§ 22.03.005 — General sewer use requirements
Code of Ordinances, City of Beaumont, Texas (through Ord. 26-062 adopted 2026-10-06 (eCode360 BE6239 publication, data-code-date 2026-10-06, scraped 2026-11-21)) · Beaumont Code of Ordinances § 22.03.005
Corpus is an independent public-information project, not the official City of Beaumont website. Stable reference: corpuslaw.us/code/5dd088f1-7249-4e48-8f95-7339562551a0
§ 22.03.005: General sewer use requirements.
(a) Prohibited discharge standards. (1) General prohibitions. No user shall introduce or cause to be introduced into the POTW any pollutant or wastewater which causes pass through or interference. These general prohibitions apply to all users of the POTW whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. (2) Specific prohibitions. No user shall introduce or cause to be introduced into the POTW the following pollutants, substances, or wastewater: (A) Pollutants which create a fire or explosive hazard in the POTW, including, but not limited to, wastestreams with a closed-cup flashpoint of less than 140 degrees F (60 degrees C) using the test methods specified in 40 CFR 261.21; (B) Wastewater having a pH less than six (6.0) or more than eleven (11.0), or otherwise causing corrosive structural damage to the POTW or equipment; (C) Any ashes, cinders, sand, mud, straw, shavings, metal, glass, rags, feathers, tar, plastics, wood, paunch manure or other solid or viscous substances in amounts which will cause obstruction of the flow in the POTW resulting in Interference; (D) Pollutants, including oxygen-demanding pollutants (BOD, etc.), released in a discharge at a flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, will cause Interference with the POTW; (E) Heat in amounts which will inhibit biological activity in the POTW resulting in Interference, but in no case heat in such quantities that the temperature at the POTW Treatment Plant exceeds 40 °C (104 °F) unless the Approval Authority, upon request of the POTW, approves alternate temperature limits; (F) Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin, in amounts that will cause Interference or Pass Through; (G) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; (H) Trucked or hauled pollutants, except at discharge points designated by the director; (I) Noxious or malodorous liquids, gases, solids, or other wastewater which, either singly or by interaction with other wastes, are sufficient to create a public nuisance or a hazard to life, or to prevent entry into the sewers for maintenance or repair; (J) Wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes and vegetable tanning solutions, which consequently imparts color to the treatment plant's effluent, thereby violating the city's NPDES permit; (K) Wastewater containing any radioactive wastes or isotopes except in compliance with applicable state or federal regulations; (L) Storm Water, surface water, ground water, artesian well water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, Noncontact Cooling Water, and unpolluted wastewater, unless specifically authorized by the director; (M) Sludges, screenings, or other residues from the pretreatment of industrial wastes; (N) Medical Wastes, except as specifically authorized by the director in an individual wastewater discharge permit; (O) Wastewater causing, alone or in conjunction with other sources, the treatment plant's effluent to fail toxicity test; (P) Detergents, surface-active agents, or other substances which might cause excessive foaming in the POTW. (b) National categorical pretreatment standards. Users must comply with the categorical pretreatment standards found at 40 CFR chapter I, subchapter N, parts 405–471. (c) State pretreatment standards. Users must comply with state pretreatment standards codified at TCEQ regulations for existing and new sources of pollution, 30 TAC part 1, chapter 315. (d) Local limits. (1) The director is authorized to establish local limits pursuant to 40 CFR 403.5(c). (2) The following pollutant limits are established to protect against pass through and interference. No person shall discharge wastewater containing in excess of the following: - | 4.0 mg/l Arsenic - | 0.3 mg/l Cadmium - | 21.0 mg/l Chromium - | 1.0 mg/l Copper - | 1.4 mg/l Cyanide - | 1.8 mg/l Lead - | 0.005 mg/l Mercury - | 4.0 mg/l Nickel - | 200 mg/l Oil and Grease - | 1.4 mg/l Selenium - | 1.18 mg/l Silver - | 10.0 mg/l Total Phenols - | 8.0 mg/l Zinc - | 3.72 mg/L Nonylphenol The above limits apply at the point where the wastewater is discharged to the POTW. All concentrations for metallic substances are for total metal unless indicated otherwise. (3) The director may develop best management practices (BMPs), by ordinance or in individual wastewater discharge permits, to implement local limits and the requirements of section 22.03.005(a). (e) Right of revision. The city reserves the right to establish, by ordinance or in individual wastewater discharge permits, more stringent standards or requirements on discharges to the POTW consistent with the purpose of this article. (f) Dilution. No user shall ever increase the use of process water, or in any way attempt to dilute a discharge, as a partial or complete substitute for adequate treatment to achieve compliance with a discharge limitation unless expressly authorized by an applicable pretreatment standard or requirement.
( Ordinance 22-070 adopted 11/22/2022 ; Ordinance 26-054 adopted 9/22/2026 )
Ask a question about Beaumont law
Corpus searches the Beaumont sections it holds and shows the ones that match, with their citations. Free, no sign-in.