§ 24.02.153 — Amendments
Code of Ordinances, City of Beaumont, Texas (through Ord. 26-062 adopted 2026-10-06 (eCode360 BE6239 publication, data-code-date 2026-10-06, scraped 2026-11-21)) · Beaumont Building and Development Code § 24.02.153
Corpus is an independent public-information project, not the official City of Beaumont website. Stable reference: corpuslaw.us/code/54067667-ad9e-4205-81ba-1ee37aa479cd
§ 24.02.153: Amendments.
(a) Section 101.2 of the Uniform Plumbing Code is hereby amended to read as follows: Section 101.2. The provisions of this code shall apply to the erection, installation, alteration, repair, relocation, replacement, addition to, use, or maintenance of commercial plumbing systems within this jurisdiction. (b) Section 102.1 of the Uniform Plumbing Code is hereby amended to read as follows: Section 102.1. Where the requirements within the jurisdiction of this Plumbing Code have any conflict with the requirements in the International Building Code or the International Residential Code, the International Building and International Residential Code shall prevail. (c) Section 102.1.1 of the Uniform Plumbing Code is hereby added to read as follows: Section 102.1.1. Where the requirements within the jurisdiction of the International Building Code or International Residential Code reference the International Plumbing Code, the International Plumbing Code shall be used as the Beaumont Plumbing Code. (d) Section 104.5 of the Uniform Plumbing Code is amended to read as follows: Section 104.5 Fee schedule. See Section 24.01.002, adoption of fee schedule, of the City Code of Ordinances. (e) Section 107.1 of the Uniform Plumbing Code is hereby amended to read as follows: Section 107.1 Application for appeal. A person shall have the right to appeal a decision of the Building Code Official to the Building Board of Appeals. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply or an equally good or better form of construction is proposed. The application shall be filed on a form obtained from the Building Official within twenty (20) days after the notice was served. (f) Section 402.5 of the Uniform Plumbing Code is hereby amended to read as follows: Section 402.5. Fixtures shall be set level and in proper alignment with reference to adjacent walls. No water closet or bidet shall be set closer than 15 inches from its center to a side wall or obstruction or closer than 30 inches center to center to a similar fixture. The clear space in front of a water closet, lavatory, or bidet shall be not less than 21 inches. No urinal shall be set closer than 12 inches from its center to a side wall or partition or closer than 24 inches center to center. (g) Section 408.4 of the Uniform Plumbing Code is hereby amended to read as follows: Section 408.4. Showers shall have a waste outlet and fixture tailpiece not less than 1-1/2 inches in diameter. Fixture tailpieces shall be constructed from the materials specified in Section 701.2 for drainage piping. Strainers serving shower drains shall have a waterway at least equivalent to the area of the tailpiece. (h) Section 408.6 of the Uniform Plumbing Code is hereby amended to read as follows: Section 408.6. Shower compartments shall be not less than 900 square inches in interior cross-sectional area. (i) Section 422.1 of the Uniform Plumbing Code is hereby amended to read as follows: Section 422.1. Requirements for this Section can be found in the International Building Code, Table 2902.1. (j) Section 508.4.1 of the Uniform Plumbing Code is hereby amended to read as follows: Section 508.4.1. The distance from the passageway access to the appliance shall not exceed 20 feet measured along the centerline of the passageway. (k) Section 601.3.2 of the Uniform Plumbing Code is hereby amended to read as follows: Section 601.3.2. Pipe identification shall be repeated at intervals not exceeding 25 feet. (l) Section 603.4.3 of the Uniform Plumbing Code is hereby amended to read as follows: Section 603.4.3. Access shall be provided to backflow preventers as specified by the manufacturer's instructions. (m) Section 701.2 of the Uniform Plumbing Code is hereby amended to read as follows: Section 701.2, Drainage Piping. All sanitary drainage and vent piping for building drain or building-sewer to be schedule 40 PVC or better, or copper tube. (n) Section 707.4 of the Uniform Plumbing Code is hereby amended to read as follows: Section 707.4 Horizontal drains and building drains. Horizontal drainage pipes in buildings shall have cleanouts located at intervals of not more than 80 feet. Building drains shall have cleanouts located at intervals of not more than 80 feet except where manholes are used instead of cleanouts, the manholes shall be located at intervals of not more than 400 feet. (o) Section 718.1 of the Uniform Plumbing Code is hereby amended to read as follows: Section 718.1. Building sewers shall run in practical alignment and at a uniform slope of not less than 1/4 inch per foot toward the point of disposal, unless otherwise approved by the authority having jurisdiction. (p) Section 908.2.6 of the Uniform Plumbing Code is hereby added to read as follows: Section 908.2.6. Horizontal Wet Venting Permitted excluding the first story.
( Ordinance 03-080 , sec. 8, adopted 10/14/03 ; 1978 Code, sec. 6-142 ; Ordinance 10-057 , sec. 19, adopted 8/3/10 ; Ordinance 17-008 , sec. 8, adopted 2/7/17 ; Ordinance 23-035 adopted 4/4/2023 ; Ordinance 24-011 adopted 3/19/2024 )
Ask a question about Beaumont law
Corpus searches the Beaumont sections it holds and shows the ones that match, with their citations. Free, no sign-in.