§ 6.09.096 — Minimum depth of surface casing; cementing of casing

Code of Ordinances, City of Beaumont, Texas (through Ord. 26-062 adopted 2026-10-06 (eCode360 BE6239 publication, data-code-date 2026-10-06, scraped 2026-11-21)) · Beaumont Code of Ordinances § 6.09.096

Corpus is an independent public-information project, not the official City of Beaumont website. Stable reference: corpuslaw.us/code/7ba61132-1fa7-41b5-8148-4d2053f63d77

§ 6.09.096: Minimum depth of surface casing; cementing of casing.

No well shall be drilled within the city limits without properly setting surface casing to a minimum depth of eight hundred (800) feet. No well shall be drilled within the city limits without cementing the surface casing by the pump and plug method with sufficient cement to completely fill all of the annular space behind such casing to the surface of the ground, and without cementing the production string by the pump and plug method with sufficient cement to completely fill all of the annular space behind the production string to at least five hundred (500) feet above the highest oil and/or gas bearing horizon. In the event a protection string of casing be required under the terms of this article, said protection string shall not be installed without cementing the protection string by the pump and plug method with sufficient cement to completely fill all the annular space behind the protection string to at least five hundred (500) feet above the highest oil and/or gas bearing horizon.

( 1958 Code, sec. 24-30 ; Ordinance 76-38 , sec. 1, adopted 3/23/76 ; 1978 Code, sec. 19-30 )

Ask a question about Beaumont law

Corpus searches the Beaumont sections it holds and shows the ones that match, with their citations. Free, no sign-in.