§ 18-532 — Meter loops
Code of Ordinances, City of Brownsville, Texas (Supp. No. 26: codified through Ordinance No. 2026-1797, enacted January 20, 2026) · Brownsville City Code § 18-532
Corpus is an independent public-information project, not the official City of Brownsville website. Stable reference: corpuslaw.us/code/5c8eed6a-29b1-47f8-95e1-5b8dceb4511b
Sec. 18-532. - Meter loops.
All electrical meter loops in a residential installation shall have an externally operated fused switch or breakers. Where a meter loop is to be changed to a new location or a new position for an increase in load and the existing panel feed is found to be of substandard size, this panel feeder shall be changed out and brought up to a standard. One or more circuits in an existing wiring installation found to be overloaded shall have an approved panel installed and shall be so divided that no circuit shall be loaded over 80 percent.
(Ord. No. 2015-672-H, 4-21-2015)