For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 157.12 — Gas well permit application and filing fees

Code of Ordinances, City of Carrollton, Texas (Includes legislation through Ord. No. 4326 adopted September 1, 2026) · Carrollton City Code § 157.12

Corpus is an independent public-information project, not the official City of Carrollton website. Stable reference: corpuslaw.us/code/b1964cd0-b078-48f1-99e6-2c2cb278be13

§ 157.12: Gas well permit application and filing fees.

(A) Every application for a gas well permit issued pursuant to this chapter shall be in writing signed by operator, or some person duly authorized to sign on his behalf, and filed with the Building Inspections Department. (B) Every application shall be accompanied by a permit fee in accordance with the comprehensive fee schedule (see chapter 31 of the City Code of Ordinances) and the standard application fee for a special use permit as listed on the Urban Development Department fee schedule. The application shall include the following minimum information: (1) The date of the application. (2) An accurate legal description of the lease property to be used for the operation site, the parcel and the production unit and name of the geologic formation as used by the Commission. Property recorded by plat shall reference subdivision, block and lot numbers. (3) Map showing proposed transportation route and road(s) for equipment, chemicals or waste products used or produced by the gas operation. (4) Proposed well name and well depth. (5) Surface owner(s), telephone number(s), fax number(s), physical address(es), and e-mail address(es) of the lease property. (6) Operator/applicant name, telephone number, fax number, physical address and e-mail address and if the operator is a corporation, the state of incorporation, and if the operator is a partnership, the names and addresses of the general partners. (7) Name, telephone number, fax number, physical address and e-mail address of the individual designated to receive notice. (8) Name and address of representatives or operator's agent with supervisory authority over all gas operation site activities and a 24-hour telephone number. (9) Location and description of all improvements and structures within 800 feet of the well. Such locations and descriptions shall be prepared by a registered professional surveyor. (10) A site plan of the proposed operation site showing the location of all improvements and equipment, including the location of the proposed well(s) and other facilities including, but not limited to, tanks, pipelines, compressors, separators and storage tanks or storage sheds. All site plans must include the following criteria: (a) Site plans shall be submitted on a sheet size of 24" × 36". (b) Property boundaries with dimensions and setback lines. (c) Location of proposed buildings and structures indicating sizes in square feet. (d) The location and intensity of exterior lighting fixtures. (e) The location of mechanical equipment. (f) Outside storage areas. (g) Curb cut locations. (h) Parking, loading, and maneuvering areas. (i) A separate plan sheet showing the location, materials and dimensions of all screening improvements as required by section 157.21. (j) On-site waste disposal locations. (k) Adjacent property lines, streets, easements immediately adjacent to the operation site. (l) Names of the owners of property immediately adjacent to the operation site. (m) City boundaries where applicable. (n) Date the drawing was prepared with name, address, and phone number of preparer. (o) Location, width and purpose of all existing easements. (p) North arrow, at a maximum scale of 1:50 immediately adjacent to the operation site. (q) All existing street names immediately adjacent to the operation site, with the proper hundred block designation shown. (r) Dimensions of all existing rights-of-way as specified on the city's thoroughfare plan. (s) Title block identifying the gas well site location. (t) Vicinity location map at 1" = 2,000'. (u) Zoning classifications of all properties shown on the site plan. (v) Location of the 100-year flood limits where applicable. (w) The X, Y, and Z (elevation) coordinates (NAD 83 Texas State Plane Coordinate System, North Central Texas FIPS 4202 (feet)) must be labeled for at least two of the perimeter corners. (x) As a minimum, a preliminary drainage study as identified in the general design standards. (y) Topographic information including contours of at least a two-foot interval or better. (11) Copies of all reports required by the Commission, specifically including a copy of the approved Railroad Commission Form W-1 and/or P-4. (12) A signed right-of-way maintenance agreement supplied by the city that provides that the operator shall repair, at his own expense, any damage caused by any activity associated with the preparation, drilling, production and operation of well. (13) A description of public utilities required during the drilling and site operations. (14) A description of the water source to be used during the drilling. (15) A copy of the Storm Water Pollution Prevention Plan (SWPPP) as required by the Commission, the Texas Commission on Environmental Quality (TCEQ), the United States Environmental Protection Agency (EPA), and/or the city. A copy of the Notice of Intent (NO) shall be submitted to the Department of Public Works at least three days prior to the commencement of any on-site activity. (16) A copy of the determination by the TCEQ of the depth of useable quality ground water. (17) Evidence of insurance and security requirements under this chapter. (18) A statement, under oath, signed by the operator or designated representative, that the information submitted with the application is, to the best of his knowledge and belief of the operator or designated representative, true and correct. (19) All required application and permit fees. (20) A tree preservation plan that conforms to the city's ordinance. (21) A copy of a Hazardous Materials Management Plan and additionally, all material safety data sheets (MSDSs) for all hazardous materials that will be located, stored, transported and/or temporarily used on the drilling site shall be provided to the City Manager or his designee and the Fire Department. (22) A copy of the operator's emergency response plan. (C) Building permit required. (1) No building or structure regulated by the current code adopted by the city shall be erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a separate permit for each building or structure has first been obtained from the Building Inspections Department. (2) It shall be the responsibility of any person, firm or corporation, upon submittal of an application for a building permit for work regulated by the current code adopted by the city, to register as a general contractor with the city. Work regulated includes, but is not limited to, construction of gates, fencing, plumbing, irrigation, electricity, roadways, entrances, compressors, flow lines, pipelines, gathering lines, tank batteries and buildings. Such registration shall be upon forms supplied by the Building Inspections Department and shall become null and void on December 31 of each year. An appropriate fee for registration shall be assessed in accordance with the city fee schedule. (3) No subdivision plat will be required.

( Ordinance 3703 , § 1( Ordinance 3145 ), adopted 9/15/2015 )

Ask a question about Carrollton law

Corpus searches the Carrollton sections it holds and shows the ones that match, with their citations. Free, no sign-in.