§ 172.31 — Installations
Code of Ordinances, City of Carrollton, Texas (Includes legislation through Ord. No. 4326 adopted September 1, 2026) · Carrollton City Code § 172.31
Corpus is an independent public-information project, not the official City of Carrollton website. Stable reference: corpuslaw.us/code/98ff756b-baf9-43d6-afd8-773d1ef3c4c2
§ 172.31: Installations.
(A) New facilities. (1) Food processing or food service facilities which are newly proposed or constructed, shall be required to design, install, operate and maintain a grease trap/interceptor in accordance with locally adopted plumbing codes, the Carrollton Restaurants and Food Establishments code, the Carrollton Food Establishment Policy or other applicable ordinances and guidelines as required by the DCO. Grease traps/interceptors shall be installed and inspected prior to issuance of a certificate of occupancy and a health permit. (2) Auto repair shops which are newly proposed or constructed with floor drain in areas of operation, shall be required to design, install, operate and maintain a grit trap/oil separator in accordance with locally adopted plumbing codes or other applicable ordinances and guidelines as required by the DCO. Grit traps/oil separators shall be installed and inspected prior to issuance of a certificate of occupancy. (B) Existing facilities. (1) Existing food processing or service facilities that change in ownership, or existing facilities which will be expanded or renovated to include a food service facility, where such facility did not previously exist or where there is an inadequately sized grease trap/interceptor, shall be required to design, install, and operate a grease trap/interceptor in accordance with locally adopted plumbing codes, the Carrollton Restaurants and Food Establishments code, the Carrollton Food Establishment Policy or other applicable ordinances and guidelines as required by the DCO. Grease traps/interceptors shall be installed and inspected prior to the issuance of a certificate of occupancy and a health permit. (2) Existing auto repair shops with floor drains in the areas of operation that change in ownership, or expanded or renovated to include floor drains in areas of operation shall be required to design, install, and operate a grit trap/oil separator in accordance with locally adopted plumbing codes, or other applicable ordinances and guidelines as required by the DCO. Grit traps/oil separators shall be installed and inspected prior to the issuance of a certificate of occupancy.
( Ordinance 3243 , adopted 8/5/2008 )
Ask a question about Carrollton law
Corpus searches the Carrollton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
