§ 94.06 — Water quality standards
Code of Ordinances, City of Carrollton, Texas (Includes legislation through Ord. No. 4326 adopted September 1, 2026) · Carrollton City Code § 94.06
Corpus is an independent public-information project, not the official City of Carrollton website. Stable reference: corpuslaw.us/code/c3bbc486-30bd-461f-84b1-44f935559629
§ 94.06: Water quality standards.
(A) Water source. (1) The water supply used to fill a pool, spa, or IWFF shall be from a potable water system. Water added to maintain the pool, spa or, IWFF water level, water used as vehicle for disinfectants or chemicals, and water used for pump priming shall be potable water. (2) All portions of the water distribution system serving a pool, spa, or IWFF shall be protected against cross-connection, backflow and back siphonage. No direct mechanical connection shall be made between the chlorinating equipment or system of piping and a sanitary sewer system, septic system, or other wastewater disposal system. (B) Disinfection. All pools, spas, and IWFFs when in use, shall be continuously disinfected by a chemical and/or process registered with the U.S. Environmental Protection Agency for water disinfection. Use of any other disinfectant besides chlorine or bromine must be approved by the DCO. (1) Disinfectant levels shall be in compliance with the state rules as provided in 25 TAC § 265.204(a) and 25 TAC § 265.306(c) as amended, and the following table. In the case where conflict exists between the tables referred to in this section, the more stringent requirements apply. Disinfectant Levels | Minimum | Ideal | Maximum Free chlorine - Pools | 1.0 ppm | 2.0 — 3.0 ppm | 8.0 ppm Free chlorine - Spas | 2.0 ppm | 3.0 ppm | 8.0 ppm Free chlorine - IWFFs | 1.0 ppm | 3.0 — 5.0 ppm | 8.0 ppm Bromine - Pools | 3 ppm | 4 — 6.0 ppm | 10.0 ppm Bromine - Spas | 4 ppm | 5.5 ppm | 10.0 ppm Bromine - IWFFs | 2.5 ppm | 5.5 — 7.5 ppm | 12.0 ppm Combined chlorine | None | None | 0.4 ppm pH | Not less than 7.0 | 7.2 — 7.6 | 7.8 Cyanuric acid | None | 30 — 50 ppm | 100 ppm ORP | 600 mV | 650 — 750 mV | 900 mV Alkalinity | 60 ppm | 60 — 180 ppm | >180 ppm Calcium hardness - Pools | 150 ppm | >150 — 400 ppm | 1,000 ppm Calcium hardness - Spas | 100 ppm | 150 — 400 ppm | 800 ppm (2) No one shall be permitted into the pool, spa or IWFF when the sanitizer residual is out of the range provided in section 94.06(8)(1). (3) Testing and recording of pool and spa disinfectant levels shall be conducted as follows: (a) Testing and recording for public pools and spas shall be conducted at least every two hours to assure compliance with this chapter's disinfectant requirements, except as provided in subsection (b). For IWFFs, semi-public pools and spas, testing and recording shall be conducted at least once a day. (b) If a public pool or spa utilizes an automated system to control disinfectant and pH, testing and recording the disinfectant level and pH shall be completed at least once per day. If necessary, tests shall be conducted more frequently to assure proper disinfectant level and pH. (c) Test samples must be representative of the pool water. (4) The site operator of a pool and/or spa shall provide and maintain a test kit which is capable of detecting disinfectant residual by the DPD method without dilution. (5) All IWFFs shall be equipped with a supplemental water treatment system that will protect the public against infection by the parasite Cryptosporidium. Supplemental water treatment systems for an IWFF include: (a) UV light disinfection installed after filtration; (b) Ozone; (c) A NSF/ANSI-50 product, combination of products or processes to control Cryptosporidium; (d) Weekly hyper-chlorination following the recommendations of the Center for Disease Control; (e) An equivalent product, process, or system approved by the DCO. (6) Water from an IWFF shall not be combined or circulated with water of other IWFFs or pools unless all of the waters are treated with a supplemental water treatment system. (7) The IWFF treatment tank shall be completely drained and cleaned at a frequency necessary to maintain water quality and sanitary conditions. (C) Other water quality parameters. (1) Requirements for pH. (a) Levels in pool, spa, and IWFF waters shall be kept between 7.0 and 7.8 pH units during hours of operation; (b) Shall be tested at the same time and frequency as the disinfectant level test; and (c) Shall be tested using a pH test kit which shall be accurate to at least 0.2 pH units. (2) Cyanuric acid requirements. (a) Cyanuric acid shall not be used in indoor pools, spas, and IWFFs; (b) If used in outdoor pools or spas, cyanuric acid must not be greater than 100 ppm; for IWFFs, cyanuric acid, but must not be greater than 50 ppm; and (c) Cyanuric acid tests shall be conducted at least once every seven days. (3) ORP reading requirements. If ORP is used, then ORP reading shall be recorded at the same time as sanitizer and pH tests are conducted. (4) Other test requirements. Alkalinity, calcium hardness, and chemical balance shall be performed at least every 30 days or as often as necessary to maintain water quality parameter and water clarity. (5) Water clarity. (a) Every pool or spa shall have clarity sufficient for bottom and main drain or an eight-inch diameter black disk or Secchi disk placed at the deepest part of a pool or spa to be readily visible. Failure to meet this requirement shall constitute grounds for immediate closure of the pool or spa. (b) The water clarity requirement is in effect any time any amount of water is in a pool or spa. (c) Allowances for normal aeration of a spa in increments of no more than 15 minutes, will be permitted. (6) Foreign matter. (a) Every pool, spa or IWFF shall be free of scum and foreign matter including sediment, dirt, slime, algae, and all other foreign matter that might be conducive to the transmission of disease. Debris shall be removed daily. (b) Any dirt, trash, refuse, animal waste, or debris on the surface of a zero depth IWFF shall be removed from the surface and the surfaces shall be flushed and sanitized with a United States Environmental Protection Agency approved disinfectant as often as is needed to prevent contamination of the water in the IWFF. The surfaces of zero depth IWFFs and the decks of all IWFFs shall be kept clean and free of pooled water to prevent the growth of algae and bacteria. (7) Temperature for heated pools and spas. (a) The water temperature in any heated public or semi-public pool or spa shall not exceed 104 degrees Fahrenheit. (b) A break-resistant and working thermometer (plus or minus one degree Fahrenheit tolerance) that is designed for use in spas shall be available for spa users and staff to monitor spa temperature. The thermometer shall be capable of measuring temperature in the range of at least 90 degrees Fahrenheit to 110 degrees Fahrenheit in increments of two degrees Fahrenheit or less. (c) Water temperature controls shall only be accessible to the site operator and not the spa user. (d) The temperature shall be checked and recorded: (i) Before users are allowed into the heated pool/spa; and (ii) Every two hours while the heated pool/spa is available for use. (8) During off-season or periods of non-use. Water clarity shall be maintained and algae growth shall be prevented in outdoor pools, spas or IWFFs not in use for an extended period of time. The facility shall not be allowed to give off objectionable odors, become a breeding site for insects, or create any other nuisance situation or safety hazard.
( Ordinance 3670 , adopted 3/17/2015 ; Ordinance 3848 , §§ 3—5, adopted 1/23/2018 ; Ordinance 4190 adopted 3/5/2024 )
Ask a question about Carrollton law
Corpus searches the Carrollton sections it holds and shows the ones that match, with their citations. Free, no sign-in.