§ 98.06 — Mechanical and electrical requirements
Code of Ordinances, City of Carrollton, Texas (Includes legislation through Ord. No. 4326 adopted September 1, 2026) · Carrollton City Code § 98.06
Corpus is an independent public-information project, not the official City of Carrollton website. Stable reference: corpuslaw.us/code/7c3cbb9b-43c1-4902-a9e5-b3f559c4561d
§ 98.06: Mechanical and electrical requirements.
(A) The owner of the structure shall provide and maintain mechanical and electrical facilities and equipment in compliance with these requirements. A person shall not occupy as owner-occupant or permit another person to occupy any premises which does not comply with these requirements. (B) Heating facilities. (1) Heating facilities shall be provided in structures as required by the city building code. (2) Cooking appliances shall not be used to provide space heating to meet the requirements of this section. (3) Indoor occupiable work spaces shall be supplied with heat to maintain a temperature of not less than 65° F (18° C) during the period the spaces are occupied. (Exception: Processing, storage and operation areas that require cooling or special temperature conditions.) (4) The required room temperatures shall be measured three feet (914 mm) above the floor near the center of the room and two feet (610 mm) inward from the center of each exterior wall. (C) Mechanical equipment. (1) All mechanical equipment, appliances, fireplaces, solid fuel burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition, and shall be capable of performing the intended function. (2) All fuel burning equipment and appliances shall be connected to an approved chimney or vent. (Exception: Fuel burning equipment and appliances which are labeled for unvented operation.) (3) All safety controls for fuel burning equipment shall be maintained in effective operation. (4) A supply of air for complete combustion of fuel and for ventilation of the space containing the fuel burning equipment shall be provided for the fuel burning equipment. (5) Devices intended to reduce fuel consumption by attachment to a fuel burning appliance, to the fuel supply line thereto, or to the vent outlet or vent piping therefrom, shall not be installed unless labeled for such purpose and the installation is specifically approved. (D) Electrical facilities. (1) Every occupied building shall be provided with an electrical system in compliance with the city electrical code. (2) All electrical equipment, wiring, outlets, receptacles, and appliances shall be properly installed and maintained in a safe and approved manner. (3) Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric luminaire. (E) Elevators, escalators and dumbwaiters. (1) Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certification of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, or the certificate shall be available for public inspection in the office of the building operator. The inspection and test shall be performed at not less than the periodical intervals listed in ASME A17.1, Appendix N, except where otherwise specified by the authority having jurisdiction. (2) In buildings equipped with passenger elevators, at least one elevator shall be maintained in operation at all times when the building is occupied. (Exception: Buildings equipped with only one elevator shall be permitted to have the elevator temporarily out of service for testing or servicing.) (F) Duct systems shall be maintained free of obstructions and shall be capable of performing the required function.
( Ordinance 3341 , adopted 11/3/2009 )
Ask a question about Carrollton law
Corpus searches the Carrollton sections it holds and shows the ones that match, with their citations. Free, no sign-in.