Sec. 34-3. - Underground electric utility service.

(a) Electric service installation. (1) All new electric utility service shall be installed underground in all building plots. All lateral electric and service lines supplying electric utility service shall be placed underground. (2) All upgraded electric utility service shall be installed underground in all building plots wherever such is sound and practical from an engineering standpoint as reasonably determined by the City. (3) Overhead feeder lines may be placed within dedicated easements in building plots when determined by the City to be necessary and appropriate, pursuant to the following criteria: a. Along the perimeter of the platted building plots. b. Adjacent to or within the right-of-way of thoroughfares identified on the current Thoroughfare Plan of the City and approved for the location of overhead utilities. c. Within alleys or other areas identified for the location of aerial utility service on the approved building plot plat. (4) Prior to the issuance of a certificate of occupancy for any structure on the building plot, the builder shall dedicate easements upon forms approved by the City for the installation of utilities, including electric. All liens and other ownership interests shall be subordinated to the easement use. (5) Where the electric service is placed underground, all street lighting and site lighting equipment shall be placed underground except for the poles on which the lights are to be affixed. (6) The Builder shall be responsible for furnishing and installing, and the expenses related thereto, of conduit, transformer pads, pull boxes, and any other civil work required for the installation of all on-site underground development feeder, lateral and service lines utilized to provide electric utility service to the building plot. The specifications for the conduit shall be approved by the Electrical Department prior to installation. The installation of the conduit shall be inspected and approved by the Electrical Department at the time of installation. (7) Where electric service is placed underground, all auxiliary equipment for such service, including, but not limited to, transformers, junction enclosures and switching devices, shall be pad-mounted on grade or shall be placed underground. (8) Temporary utility service may be provided via overhead line extension. (b) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: Builder means any person, firm or corporation who applies for or is issued a permit by the Building Official to erect, construct, enlarge, install, alter, repair, move, improve, remove, convert or demolish any building, structure, electrical, gas, mechanical, plumbing or fire protection system located within the municipal corporation; or a permit or permission to develop property. Building plot means all of the land within a project, whether one or more lots, developed according to a common plan or design for similar or compatible uses, which singularly or in phases is treated as such for site plan review purposes. The determination of the boundaries of a building plot shall be made as the first step in the site plan or project review, unless such determination has previously been made at the time of plat approval. For development, not subject to site plan review, the building plot or premises shall be the exterior boundary of any included lots, in the event that the structure is built upon more than one lot. Feeder line means any line, wire, or cable and appurtenances which distributes, transmits, or delivers an electric utility service from a source to a general area or to multiple developments, and not to a specific end user. Lateral line means any line, wire, or cable and appurtenances used to distribute, transmit, or deliver electric utility service from a feeder line to two or more sites or end users of the electric utility service within a specific development. Lot means the physical and undivided tract or parcel of land as shown on a duly recorded plat. Plot plan means a plan showing the use of land, including locations of buildings, drives, sidewalks, parking areas, drainage facilities and other facilities to be constructed, and anything else in accordance with Sections 10 and 11 of the Unified Development Ordinance (see App. A) of the City. Service line means any line, wire, or cable and appurtenances used to distribute, transmit, or deliver an electric utility service from a source of supply, feeder line, or lateral line directly to an end user. Upgraded electric utility service means any increase in electric service capacity or any relocation of the electric service entrance.

(Code 2011 (Repub.), § 3-5; altered in 2017 recodification)

Ask a question about College Station law

Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.