§ 40-158 — Interceptors
Code of Ordinances of the City of College Station, Texas (Supp. No. 10 Update 2: codified through Ordinance No. 2026-4726, adopted October 22, 2026) · College Station Code of Ordinances § 40-158
Corpus is an independent public-information project, not the official City of College Station website. Stable reference: corpuslaw.us/code/9d94b34c-7b97-49c7-bf8f-6b47d35a0681
Sec. 40-158. - Interceptors.
(a) Purpose. The purpose of this section is to aid in the prevention of sanitary sewer blockages and obstructions from contributions and accumulation of wastes, including, but not limited to, fats, oils, greases, sand, and grit, into the City's sanitary sewer system from industrial or commercial customers, including, but not limited to, food preparation and serving facilities, car wash facilities, automotive repair and maintenance shops. (b) Interceptor maintenance, recordkeeping, and grease removal. (1) Grease interceptors shall be installed by all retail and wholesale food preparation establishments. The grease interceptors shall be installed at the customer's expense. Grease interceptors may also be required in non-cooking or cold dairy and frozen foodstuffs establishments and other industrial or commercial customers when they are deemed necessary by the City for the proper handling of liquid wastes containing grease. All grease interceptors shall be serviced and emptied of accumulated waste (grease cap and sludge pocket) as required to maintain the interceptor above its minimum design capability or effective volume, but not less often than every 30 days, unless a different schedule is established in writing by the City. Customers who are required to pass wastewater through a grease interceptor shall: a. Provide a minimum hydraulic retention time of 24 minutes at actual peak flow or 12 minutes at calculated theoretical peak flow rate as predicted by the adapted plumbing code fixture criteria, between the influent and effluent baffles with 20 percent of the total volume of the grease interceptor being allowed for sludge to settle and accumulate, identified hereafter as a "sludge pocket." b. Ensure that the grease interceptors shall be kept free of inorganic solid materials such as grit, rocks, gravel, sand, eating utensils, cigarettes, shells, towels, rags, etc., which could settle into the sludge pocket and thereby reduce the effective volume of the grease interceptor. c. Ensure that if any skimmed or pumped wastes or other materials are removed from the grease interceptor and treated in any fashion on-site, and then reintroduced back into the grease interceptor as an activity of and after said on-site treatment, the customer shall be responsible for the attainment of established grease numerical limits consistent with and contained in this subdivision on all discharges of wastewater from said grease interceptor discharged into the sanitary sewer collection and treatment system. d. Operate the grease interceptor in a manner so as to maintain said device such that attainment of the oil and grease limit is consistently achieved. The term "consistent" shall mean any grab sample taken from said grease interceptor discharge shall be subject to terms of numerical limit attainment described in this subdivision. If an establishment desires, because of documented space constraints, an alternate to an out-of-building grease interceptor, the request for an alternative location shall contain the following information: 1. Lot plat containing the building footprint, location of City sewer main and other utilities with their respective easements, and surveyed distances in relation to available exterior space outside of the building. 2. Existing plumbing at or in a site that uses common plumbing for all services at that site. e. Keep the area around the grease interceptor free of accumulated fats, oils and greases, and the area around the trap shall not cause an odor or health hazard. f. Maintain a written record (on-site) of interceptor maintenance for a three-year period. All such records, including liquid waste manifests, shall be available for inspection by the City during the normal work week (Monday through Friday 8:00 a.m. to 5:00 p.m.). g. Ensure that the grease interceptor is cleaned and maintained by a transporter registered with the State. The liquid waste collected shall be disposed of at a State-authorized processing or treatment facility, a liquid waste transfer station, or a municipal solid waste landfill. (2) The use of biological additives as a grease degradation agent is conditionally permissible, upon prior written approval of the City. Any establishment using this method of grease abatement shall maintain the trap or interceptor in such a manner that attainment of the oil and grease discharge limit, as measured from the trap's outlet, is consistently achieved. (3) The use of automatic grease removal systems is conditionally permissible, upon prior written approval of the Director of College Station Utilities, the City Building Official or designee, and the Brazos County Health Department Environmental Health Services. Any establishment using this equipment shall operate the system in such a manner that attainment of the oil and grease discharge limit, as measured from the unit's outlet, is consistently achieved. (4) A 1,000-gallon interceptor shall be a minimum standard for all cooking or food processing establishments. The City reserves the right to make determinations of grease interceptor adequacy and need, based on review of all relevant information regarding the proposed grease interceptor performance, facility site inspection and building plan review. The City may require an interceptor of larger capacity, or repairs, modification, or replacement of present traps. (5) If a customer does not agree with the sample results taken by the City, the customer will have the option to have two separate samples collected and analyzed by an independent contractor at the customer's expense. All sampling shall be during the peak wash time for the cooking establishment. The average of the two samples will be accepted as the official discharge results. The City shall have a representative on-site during the sampling. (6) Only sinks used for kitchen utensil and cookware washing, dishwashers, and floor drains in the kitchen area shall be connected to the grease interceptor. Outside covered areas, that are constructed as to exclude all stormwater, with floor drains utilized to wash kitchen vent filters and other grease laden kitchen fixtures may, with the City's approval, be connected to the grease interceptor. (7) Except as provided herein, for a period of one year following adoption of the ordinance from which this subdivision is derived, although installation of grease interceptors shall be required at the time of adoption of the ordinance from which this subdivision is derived, no enforcement actions will be taken under this subdivision for failure to achieve discharge limits from grease interceptors. If during this one-year period an obstruction of a City sewer main or lateral occurs and causes a sewer back-up and/or overflow and the back-up or overflow can be attributed in part or in whole to an accumulation of grease or other wastes discharged by the customer into the City's sewer main or lateral, the person is responsible for any costs incurred from damage or stoppages caused by the sewer back-up and/or overflow. The City may bill the person for all direct and indirect costs incurred by the City due to the back-up and/or overflow. (8) Access manholes, with a minimum diameter of 30 inches, shall be provided over each grease chamber and sanitary tee. The access manholes shall extend at least to finish grade and be designed and maintained to prevent water inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, liquid waste removal, and discharge sampling activities. (c) Oil, sand, and grit interceptors. (1) If the City permits the pretreatment or equalization of waste flows, the design and installation shall be subject to the review and approval of the Director and subject to the requirements of all applicable codes, ordinances and laws. (2) When a customer operates a facility whose wastewater is associated with discharges of oil, sand, grit and gravel an interceptor shall be installed. Oil, sand, and grit interceptors shall be installed by the customer as required by the City and at the customer's expense. Facilities required to install grit or grease interceptors include, but are not limited to, automatic and coin operated laundries, car washes, fueling stations, commercial garages or similar businesses having wash or grease racks. Customers who are required to pass wastewater through an oil, sand or grit interceptor shall: a. Maintain ambient fluid temperatures of 40 to 70 degrees Fahrenheit at standard atmospheric conditions; b. Maintain an oil/water specific gravity differential of 0.15; c. Maintain the oil concentration in the wastewater so that it meets all Federal, State and local discharge limits; d. Maintain a written record on-site of interceptor maintenance for three years. All such records, including liquid waste manifests, shall be available for inspection by the City during the normal workweek (Monday through Friday 8:00 a.m. to 5:00 p.m.). (3) Except as provided herein, for a period of one year following adoption of the ordinance from which this subdivision is derived, although installation of oil, sand, or grit interceptors shall be required at the time of adoption of the ordinance from which this subdivision is derived, no enforcement actions will be taken under this subdivision for failure to achieve discharge limits from the interceptors. If during this one-year period an obstruction of a City sewer main or lateral occurs and causes a sewer back-up and/or overflow and the back-up or overflow can be attributed in part or in whole to an accumulation of waste discharged by the customer into the City's sewer main or lateral, the person is responsible for any costs incurred from damage or stoppages caused by the sewer back-up and/or overflow. The City may bill the person for all direct and indirect costs incurred by the City due to the back-up and/or overflow. (4) Access manholes, with a minimum diameter of 30 inches, shall be provided over each oil or grit chamber and sanitary tee. The access manholes shall extend at least to finish grade and be designed and maintained to prevent water inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, liquid waste removal, and discharge sampling activities. (5) The grit interceptor shall be cleaned and maintained by a transporter registered with the State. The liquid waste collected shall be disposed of at a State-authorized processing or treatment facility, a liquid waste transfer station, or a municipal solid waste landfill.
(Code 2011 (Repub.), § 11-6(I); altered in 2017 recodification)
Ask a question about College Station law
Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.