§ 14-241 — Electrical code
Code of Ordinances, City of Corpus Christi, Texas (Supp. No. 44: codified through Ordinance No. 033940, enacted June 2, 2026) · Corpus Christi Code of Ordinances § 14-241
Corpus is an independent public-information project, not the official City of Corpus Christi website. Stable reference: corpuslaw.us/code/b02d5577-5908-4f75-960f-75224b6cb549
Sec. 14-241. - Electrical code.
The National Electrical Code, 2020 Edition, as published by the National Fire Protection Association, is incorporated by reference and adopted as the Electrical Code for the City of Corpus Christi with the following local amendments (Additions to the National Electrical Code are shown as underlined text. Deletions to the National Electrical Code are shown as strikethroughs): Section 80.13(13) Authority Whenever any installation subject to inspection prior to use is covered or concealed without having first been inspected, the authority having jurisdiction shall be permitted to require that such work be exposed for inspection. The authority having jurisdiction shall be notified when the installation is ready for inspection and shall conduct the inspection within 2 days. Section 80.19(F) Inspection and Approvals (3) When any portion of the electrical installation within the jurisdiction of the Electrical Inspector is to be hidden from view by the permanent placement of parts of the building, the person, firm, or corporation installing the equipment shall notify the Electrical Inspector, and the equipment shall not be concealed until it has been approved by the Electrical Inspector or until 2 days have elapsed from the time of such notification, provided that on large installations, where the concealment of equipment proceeds continuously, the person, firm, or corporation installing the equipment shall give the Electrical Inspector due notice in advance, and inspections shall be made periodically during the progress of the work. Section 80.27(A) Inspectors Qualifications Certificate. All electrical Inspectors shall be certified by a nationally recognized inspector certification program accepted by the Board. The certification program shall specifically qualify the inspector in electrical inspections. No person shall be employed as an Electrical Inspector unless that person is the holder of an Electrical Inspector's Certificate of the qualification issued by the Board, except that any person who on the date on which this law went into effect was serving as a legally appointed Electrical inspector of the City of Corpus Christi shall, upon application and payment of the prescribed fee and without examination, be issued a special certificate permitting him or her to continue to serve as an Electrical Inspector in the same territory. Section 80.29 Liability for Damages. Article 80 shall not be construed to affect the responsibility or liability of any party owning, designing, operating, controlling, or installing any electrical equipment for damages to persons or property caused by a defect therein, nor shall the city or any of its employees be held as assuming any such liability by reason of the inspection, reinspection, or other examination authorized. Section 90.2(B) Not Covered. This code does not cover the following. (1) Installations in ships, watercraft other than floating buildings, railway rolling stock, aircraft, or automotive vehicles other than mobile homes and recreational vehicles. Informational Note: although the scope of this code indicates the code does not cover installations in ships portions of this code are incorporated by reference into Title 46, Code of Federal Regulations Parts 110-113. (2) Installations underground in mines and propelled mobile surface mining machinery and its attendant electrical trailing cable. (3) Installations of railways for generation, transformation, transmission, energy storage, or distribution of power, used exclusively for operation of rolling stock or installations used exclusively for signaling and commutations purposes. (4) Installations of communications equipment under the exclusive control of communications utilities located outdoors or in building spaces used exclusively for such installations. (5) Installations under the exclusive control of an electric utility where such installations: a. Consist of service drops or service laterals, and associated metering, or b. Are on property owned or leased by the electric utility for the purpose of communications, metering, generation, control, transformation, transmission, energy, storage, or distribution of electric energy, or c. Are located in legally established easements or rights-of-way, or d. Are located by other written agreements either designated by or recognized by public service commissions, utility commissions, or other regulatory agencies having jurisdiction for such installations. These written agreements shall be limited to installations for the purpose of communications, metering, generation, control, transformation, transmission, energy storage, or distribution of electric energy where legally established easements or tights-of-way cannot be obtained. These installations shall be limited to federal lands, Native American reservations through the U.S. Department of the Interior Bureau of Indian Affairs, military bases, lands controlled by port authorities and state agencies and departments, and lands owned by railroads. (6) Installations of exterior lighting on property owned or leased by the utility, in public streets or alley rights-of-way, and in irrevocable utility or electric easements. If the easement on which the outdoor lighting is being installed is not shown on a plat that is filed for record with the county clerk's office, the electrical utility must present a map or survey showing the location of the easement and the location of the proposed outdoor lighting. Section 210.8(A) Dwelling Units. All 125 -volt , single-phase, 15- and 20 ampere through 250-volt receptacles install in the locations specified in 210 (A)(1) through (A)(12) and supplied by a single-phase branch circuit rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms. (2) Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use. (3) Outdoors. Exception to (3): Receptacles that are not readily accessible and are supplied by a branch circuit dedicated to electric snow-melting, deicing, or pipeline and vessel heating equipment shall be permitted to be installed in accordance with the 426.28 or 427.22, as applicable. (4) Crawl spaces—at or below grade level. (5) Basements. Exception to (5): A receptacle supplying only a permanently installed fire alarm or burglar alarm system shall not be required to have ground fault circuit-interrupter protection. Informational Note: See 760.41(B) and 760.121(B) for power supply requirements. Receptacles installed under the exception to 210.8(A)(3) shall not be considered as meeting requirements of 210.52(G). (6) Kitchens—where the receptacles are installed to serve the countertop surfaces. (7) Sinks—where receptacles are installed within 1.8 m(6ft) from the top inside edge of the bowl of the sink. (8) Boathouses. (9) Bathtubs or shower stalls—where receptacles are installed within 18m (6ft) of the outside edge of the bathtub or shower wall. (10) Laundry areas. Exception to (1) through (3), (5) through (8), and (10): Listed locking support and mounting receptacles utilized in combination with compatible attachment fittings installed for the purpose of serving a ceiling luminaire or ceiling fan shall not be required to be ground-fault circuit-interrupter protected. If a general- purpose convenience receptacle is integral to the ceiling luminaire or ceiling fan, GFCI protection shall be provided. (11) Indoor damp and wet locations. (12) Receptacle outlets supplying Refrigerators or Freezers will not require AFCI/GFGI protection if supplied by a dedicated circuit with a 20-amp 120-volt Single Receptacle device. Section 210.11(C)(3) Bathroom Branch Circuits. In addition to the number of branch circuits required by other parts of this section, one or more, not exceeding three (3), 12-volt, 20-ampere branch circuit shall be installed to supply installed devices or receptacle outlet(s) required by 210.52(D) and any countertop and similar work surface receptacle outlets. Such circuits shall have no other outlets. Section 210.19(1) General. Branch-circuit conductors shall have an ampacity not less that the larger of 210.19(A)(1)(a) or (A)(1)(b) and comply with 110.14(C) for equipment terminations. (a) Where a branch circuit supplies continuous loads or any combination of continuous and noncontinuous loads, the minimum branch-circuit conductor size shall have an ampacity not less that the noncontinuous load plus 125 percent of the continuous load in accordance with 310.14. (b) the minimum branch-circuit conductor size shall have an ampacity not less than the maximum load to be served after the application of any adjustment or correction factors in accordance with 310.15. Exception No. 1 to (1)(a): if the assembly, including the overcurrent devices protection the branch circuits(s), is listed for operation at 100 percent of its rating, the ampacity of the branch-circuit conductors shall be permitted to be not less than the sum of the continuous load plus the non-continuous load in accordance with 110.14(c). Exception No. 2 to (1)(a) to (1)(b): Where a portion of a branch circuit is connected at both its supply and load ends to separately installed pressure connection as covered in 110.14(C)(2), it shall be permitted to have an allowable ampacity, in accordance with 310.15, not less that the sum of the continuous load plus the noncontinuous load. No portion of a branch circuit installed under this exception shall extend into an enclosure containing either the branch-circuit load terminations. (c) Minimum amperage. All circuits, except lighting circuits, must have a minimum current capacity of twenty (20) amperes. 210.52.A.1 Spacing Exception: measurement does not include requirement behind doors. 210.52.C.3 is deleted. 210.53 Receptacles Required for Non-Dwellings. Commercial buildings must have a minimum of one (1) receptacle installed for every twenty (20) feet measured horizontally around the interior wall at the floor level of each room, excluding storage rooms. Article 230.11 Service-Entrance Conductor and Sub feed Installation Methods. Service-entrance conductors and sub feeds to electrical distribution panels must run in conduits or raceways. A masthead used for support of service drop conductors must extend not less than forty-two (42) inches above the roof and must be two (2) inches or larger rigid metal conduit. Section 230.70 General. Means shall be provided to disconnect all ungrounded conductors in a building or other structure from the service location. (A) Location. There service disconnection means shall be installed in accordance with 230.70(A)(1), (A)(2), and (A)(3). (1) Readily Accessible Location. The service disconnecting means shall be installed at a readily accessible location either outside of a building or structure or inside nearest the point of entrance of the service conductors. (2) Bathrooms. Service disconnection means shall not be installed in bathrooms. (3) Remote Control. Where a remote-control device(s) is used to actuate the service disconnection means shall be located in accordance with 230.70(A)(1). (B) Marking. Each service disconnect shall be permanently marked to identify it as a service disconnect. (C) Suitable for Use. Each service disconnecting means shall be suitable for the prevailing conditions. Service equipment installed in hazardous (classified) locations shall comply with the requirements of Articles 500 through 517. (D) Minimum Fault Current Protection. All electrical service entrance equipment, except for temporary construction loops, must be provided with fault current protection of not less than twenty-two thousand (22,000) amps. (E) Exception For Certain Lighting Fixtures Installed on Poles. A service disconnect means is not required on a pole with a lighting fixture, if: (1) The pole is in a location accessible to the public, such as in parking lots, parks, etc., and a disconnecting means is installed in the circuit powering the fixture at a secure location, or with a lockable disconnect which is permanently identified at the location of the disconnect; or (2) The fixture and all wiring providing power to the fixture are under the exclusive control of an electric distribution utility. Section 242.14.C Type 2 SPD's - Separately Derived System Exception: not required for single family homes. Section 300.5(L) Non-metallic Electrical Conduit Required. Only non-metallic electrical conduit may be installed underground. The use of metallic electrical conduits is prohibited in underground installations. Table 310.5 Exception No. 1: The minimum size conductor that may be used on any circuit, except a lighting circuit, is 12. 408.24 Spare Raceways. For each panel a spare one-inch raceway must be installed from the panel to an accessible location. Exception No. 1: A spare raceway is not required if there is no access in the attic or from floor above or below the panel. Exception No. 2: A spare raceway is not required if the walls and ceiling adjacent to panel are not covered. Exception No. 3: Except single family residential installations where a spare raceway can be installed for multiple panels. 408.25 Spare Spaces. New Panels shall have no less than 1 spare space for future expansion. 514.8 Underground Wiring. Underground wiring shall be installed in threaded metal conduit or threaded steel intermediate metal conduit or SCH 80 PVC conduit. Any portion of electrical wiring that is below the surface of a Class I, Division I or a Class I, Division 2 location [as classified in Table 514.3(B)(1) and Table 514(B)(2)] shall be sealed within 3.05 m (10 ft) of the point of emergence above grade. Except for listed explosionproof reducers at the conduit seal, there shall be no union, coupling, box, or fitting between the conduit seal and the point of emergence above grade. Refer to Table 300.5. Exception No. 2: Type PVC conduit, Type RTRC conduit, and Type HDPE conduit shall be permitted where buried under not more than 600 mm (2 ft) of cover. Where Type PVC conduit, Type RTRC conduit or Type HDPE conduit is used, threaded rigid metal conduit, or threaded steel intermediate metal conduit shall be used for the last 600 mm (2ft) of the underground run to emergence or the point of connection to the aboveground raceway, and an equipment grounding conductor shall be included to provide electrical continuity of the raceway system and for grounding of non-current-carrying metal parts. Article 696 Electrically Charged Fencing 696.1 Electrically charged fencing. Installation of electrically charged fencing for purpose of security, animal containment and other similar uses must be under approved Underwriters' Laboratories, or any other nationally recognized testing agency, devices. Upon installation such fencing must be clearly identified with signage not to exceed a fifty-foot maximum spacing on this electrical fencing. The signage must be legible from five (5) feet and must be properly maintained while fence is in use.
(Ord. No. 030847, 5-17-2016; Ord. No. 031247, § 2, 9-19-2017; Ord. No. 032058, § 14, 3-17-2020; Ord. No. 032968, § 4, 1-31-2023)
Ask a question about Corpus Christi law
Corpus searches the Corpus Christi sections it holds and shows the ones that match, with their citations. Free, no sign-in.
