§ 14-281 — Plumbing code
Code of Ordinances, City of Corpus Christi, Texas (Supp. No. 44: codified through Ordinance No. 033940, enacted June 2, 2026) · Corpus Christi Code of Ordinances § 14-281
Corpus is an independent public-information project, not the official City of Corpus Christi website. Stable reference: corpuslaw.us/code/81bd38f6-7761-431e-b437-84ef5e593992
Sec. 14-281. - Plumbing code.
The International Plumbing Code, 2021 Edition, as published by the International Code Council, is incorporated by reference and adopted as the Plumbing Code for the City of Corpus Christi with the following local amendments (Additions to the International Plumbing Code are shown as underlined text. Deletions to the International Plumbing Code are shown as strikethroughs): 101.1 Title. These regulations shall be known as the Plumbing Code of the City of Corpus Christi hereinafter referred to as "this code." 102.8.3 Appendices. Appendix B Rates of Rainfall for Various Cities, Appendix C Structural Safety, Appendix D Degree Day and Design Temperatures, Appendix E Sizing of Water Piping are hereby adopted. 103.1 Creation of agency. The City of Corpus Christi Development Services is hereby created named and the official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. 108.2 Required inspections and testing. The code official, upon notification from the permit holder or the permit holder's agent, shall make the following inspections and such other inspections as necessary, and shall either release that portion of the construction or shall notify the permit holder or an agent of any violations that must be corrected. The holder of the permit shall be responsible for the scheduling of such inspections. 1. Underground inspection shall be made after trenches or ditches are excavated and bedded, piping installed, and before any backfill is put in place. Rough-in inspection shall be made after trenches or ditches are excavated and bedded, piping installed, and before any backfill is put in place. 2. Rough-in inspection Top Out inspection shall be made after the roof, framing, fire blocking, firestopping, draft stopping and bracing is in place and all sanitary, storm and water distribution piping is roughed-in, and prior to the installation of wall or ceiling membranes. A pressure test is required on all piping before the inspection is approved. 3. Final inspection shall be made after the building is complete, all plumbing fixtures are in place and properly connected, and the structure is ready for occupancy. ***Exception or note: For single family residential, refer to the adopted International Residential Code. 109.2 Schedule of permit fees. Where work requires a permit, a fee for each permit shall be paid as required, in accordance with the schedule as established by the applicable governing authority. Reference the City of Corpus Christi fee schedule. 110.1.1. Design of gray water disposal. The plans and installation of a gray water disposal system providing for the storage of gray water must be designed and certified by a registered professional engineer or registered professional sanitarian. Section 114 of the International Plumbing Code is deleted. Refer to Section 14-206(a) Construction Trade Advisory Appeal Board for details on the establishment, duties and powers, and appeals process of the construction trade advisory & appeals board. Section 115 of the International Plumbing Code is deleted. Refer to Section 14-207 Violations and Penalties. 305.4.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be installed not less than eighteen (18) inches below finished grade at the point of septic tank connection. Building sewers shall not be less than twelve (12) inches below grade. 312.10.1 Inspections. All backflow prevention assemblies required by Texas Commission on Environmental Quality (TCEQ) Publication RG-195 and 30 Texas Administrative Code Chapter 290 shall be tested and certified to be operating within specifications upon installation and immediately after repairs or relocation. All backflow prevention assemblies where there is a health contamination hazard as identified by Texas Commission on Environmental Quality (TCEQ) Publication RG-195 and 30 Texas Administrative Code § 290.47(f) shall be tested and certified to be operating within specifications at the time of installation, immediately after repairs or relocation, and at least annually. All testing and certification shall be performed by a state-licensed Backflow Prevention Assembly Tester. The Backflow Prevention Assembly Tester must file an original copy of the initial test certification and each annual certification with the City's Third-Party database within ten (10) days of the testing. All connections between an industrial facility or industrial processing unit and the City's water system must be equipped with a reduced pressure backflow preventer, which will prevent backflow and back siphonage. A reduced pressure backflow preventer must be installed at each City meter servicing potable water and fire service lines. An Industrial District Affidavit must be submitted immediately upon installation or repair by a Texas certified Professional Engineer for each City water meter that is on the industrial customer's property and submitted to the Utilities Department or designee. The City has the right to inspect any connections to the City's water system, including any valves and backflow prevention devices. If the owner or operator of an industrial facility or industrial processing unit fails to install, test or timely provide backflow test results, or maintain valves and backflow prevention devices in good operating condition, the City may refuse to connect the industrial facility or industrial processing unit to, or disconnect the facility or unit from, the City's water supply system. In addition, the City may authorize the backflow prevention device be tested, repaired and/or replaced with all associated charges to be charged to the customer's utility bill. 403.1.1 Fixture calculations. To determine the occupant load of each sex, the total load shall be divided in half. To determine the required number of fixtures, the fixture ratio or ratios for each fixture type shall be applied to the occupant load of each sex in accordance with Table 403.1. fractional numbers resulting from applying the fixture ratios of Table 403.1 shall be rounded up to the next whole number. For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number: Exceptions: 1. the total occupant load shall not be required to be divided in half where approved statistical data indicate a distribution of the sexes of other than 50 percent. 2. Where multiple user facilities are designed to serve all genders, the minimum fixture count shall be calculated 100 percent, based on total occupant load. In such multiple user facilities each fixture type shall be in accordance with ICC A117.1 and each urinal that is provided shall be located in a stall. 3. Distribution of the sexes is not required where single-user water closets and bathing room fixtures are provided in accordance with Section 403.1.2. 403.2 Separate facilities: Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: 1. Separate facilities shall not be required for dwelling units and sleeping units. 2. Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 15 or fewer. 3. Separate facilities shall not be required in mercantile occupancies in which maximum occupant load is 100 or fewer. 4. Separate facilities shall not be required in business occupancies in which the maximum occupant load is 25 or fewer. 5. Separate facilities shall not be required to be designated by sex where single-user toilet rooms are provided in accordance with section 403.1.2 6. Separate facilities shall not be required where rooms have both water closets and lavatory fixtures are designed for use by both sexes and privacy for water closets is provided in accordance with Section 405.3.4. Urinals shall be located in an area visually separated from the remainder of the facility or each urinal that is provided shall be located in a stall. 606.2 Location of shutoff valves. Shutoff valves shall be installed in the following locations: 1. On the fixture supply to each plumbing fixture, other than bathtubs and showers in one- and two-family residential occupancies and other than in individual sleeping units that are provided with unit shutoff valves in hotels, motels, boarding houses, and similar occupancies. 2. On the water supply pipe to each sill-cock, hose bib, or wall hydrant. 3. On the water supply pipe to each appliance or mechanical equipment. 608.1.2 Failure to report test result. Upon the failure of the utility customer to report the result of the required test and certification of the backflow prevention device, the City Manager, or designee, may authorize the backflow prevention device to be tested and repaired with all associated charges to be placed on the customer's utility bill, and may also authorize the stoppage of the supply of water to the service address. The water may not be restored, except upon provision of the report of the required test and certification that the backflow prevention device is operating in accordance with specifications. 608.15 Location of backflow preventers. Access shall be provided to backflow preventers as specified by the manufactured instructions. If needed, additional access and clearance must be provided to allow for the required testing, maintenance, and repair. Access and clearance must require a minimum of one (1) foot (305 mm) between the lowest portion of the assembly and grade, floor, or platform. Installations elevated more than five (5) feet (1.53 m) above the floor or grade, measured from the center line of the valve, must be provided with a permanent platform capable of supporting five hundred (500) pounds and provide mechanical support. 608.17.1.11 Carbonated beverage dispensers. A reduced pressure assembly backflow preventer is required when copper piping serves water to a carbonated beverage dispenser. The required backflow preventer shall comply with Texas Commission on Environmental Quality (TCEQ) public drinking water regulations. For TCEQ regulations, see 30 Texas. Administrative Code §290.47(f), Appendix F: Assessment of Hazards and Selection of Assemblies. When a carbonated beverage dispenser is not served by copper piping, an approved ASSE 1022 dual check with atmospheric vent backflow preventer (built into the carbonator assembly) may be used in lieu of the reduced pressure assembly. 608.17.4 Connections to automatic fire sprinkler systems and standpipe systems. The potable water supply to automatic fire sprinkler systems and standpipe systems shall be protected against backflow by a double check backflow prevention assembly, a double check fire detector protection backflow prevention assembly or a reduced pressure principal fire detector protection backflow prevention assembly. Exceptions: 1. Where systems are installed as a portion of the water distribution system in accordance with the requirements of this code and are not provided with a fire department connection, isolation of the water supply system shall not be required. 2. Isolation of the water distribution system is not required for deluge, preaction or dry pipe systems. SECTION 614 LAWN IRRIGATION SYSTEMS 614.1 Landscape Irrigation Systems. Landscape Irrigation Systems are required to comply with chapter 344 of part 1 of title 30 of the Texas Administrative Code. 708.1.1 Horizontal drains and building drains. Horizontal drainage pipes in buildings shall have cleanouts located at intervals of not more than 100 feet (30,480 mm) eighty (80) ft (24,384 mm) apart. Building drains shall have cleanouts located at intervals of not more than 100 feet (30,480 mm) eighty (80) ft (24,384 mm) except where manholes are used instead of cleanouts, the manholes shall be located at intervals of not more than 400 feet (122 m). The interval length shall be measured from the cleanout or manhole opening, along the developed length of the piping to the next drainage fitting providing access for cleaning, the end of the horizontal drain or the end of the building drain. Exception: Horizontal fixture drain piping serving a nonremovable trap shall not be required to have a clean out for the section of piping between the trap and the vent connection for such trap. 708.1.2 Building sewers. Building sewers smaller than 8 inches (203 mm) shall have cleanouts located at intervals of not more than 100 feet (30,480 mm) eighty (80) ft (24,384 mm). Building sewers 8 inches (203 mm) and larger shall have a manhole located not more than 200 feet (60 960 mm) from the junction of the building drain and building sewer and at intervals of not more than 400 feet (122 m). The interval length shall be measured from the cleanout or manhole opening, along the developed length of the piping to the next drainage fitting providing access for cleaning, a manhole or the end of the building sewer. 708.1.3 Building drain and building sewer junction. The junction of the building drain and the building sewer shall be served by a cleanout that is located at the junction or within 10 feet (3048 mm) of the developed length of piping upstream of the junction. There shall be a two-way double riser cleanout near the junction of the building drain and the building sewer. For the requirements of this section, the removal of the water closet shall not be required to provide cleanout access. SECTION 804 ELEVATOR SUMP DISCHARGE 804.1 General. Discharge of elevator sump sumps shall be to an approved location. Section 903.1.1 Roof extension. All open vent pipes that extend through a roof shall terminate not less thansix (6) inches (152.4 mm) above the roof. 916.3.1 Vertical vents. A vertical vent must be installed on the drain line downstream of the island vent configuration, unless the building drain branch line is at least three (3) inches (76 mm). This is section 916 island vent fixtures.
(Ord. No. 030847, 5-17-2016; Ord. No. 031067, § 1, 2-14-2017; Ord. No. 031344, § 1, 1-23-2018; Ord. No. 031456, § 1, 6-19-2018; Ord. No. 032058, § 14, 3-17-2020; Ord. No. 032968, § 7, 1-31-2023; Ord. No. 033156, §§ 2, 5, 9-5-2023)
Ask a question about Corpus Christi law
Corpus searches the Corpus Christi sections it holds and shows the ones that match, with their citations. Free, no sign-in.
