For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26-318 — Definitions

Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton City Code § 26-318

Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/fac1a89b-325b-473b-8330-b7ae8df81e88

Sec. 26-318. - Definitions.

The following words, terms, and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Advanced metering infrastructure or AMI means a metering system that enables the automated, remote collection of utility consumption data. This system utilizes a network that is capable of automatically transmitting meter readings to the utility over a communication network, eliminating the need for a utility employee to physically visit the meter to obtain a reading. Air gap or AG means a physical separation between the free-flowing discharge end of a potable water supply pipe or appurtenance and an open or non-pressure receiving vessel, plumbing fixture, or other device. An approved air-gap separation shall: (1) Be at least twice the diameter of the supply pipe measured vertically above the overflow rim of the vessel, plumbing fixture, or other device; (2) Be in no case less than one (1) inch; and (3) Comply with the 30 Tex. Admin. Code § 290.44 and the Plumbing Code. Applicable laws means the ordinances, codes, and regulations of the City of Denton, as well as the rules and regulations of the commission and any other state or federal laws governing cross-connection control or backflow prevention. Approved backflow prevention assembly means a backflow prevention assembly that is a DC, DCDA, DCDA-II, RP, RPDA-II, SVB, or PVB and complies with this article, the Plumbing Code, and 30 Tex. Admin. Code § 290.44. In the case of a conflict between this article, state laws or rules, or the Plumbing Code, the more restrictive standard shall apply. Atmospheric vacuum breaker backflow prevention assembly or AVB means a backflow prevention assembly containing an air inlet valve, a check seat, and air inlet port(s). In no circumstances are AVBs approved backflow prevention assemblies in the City of Denton. Auxiliary water supply means any supply of water other than water from the City of Denton's Public Water System. Backflow means an undesirable reversal of flow of water or a mixture of water and other liquids, gases, or other substances, from any source or sources, into the distribution pipes of the potable water supply. Backflow prevention assembly or backflow assembly means a mechanical plumbing device that, when properly installed and maintained, prevents backflow from a private water system into the public water system. Backflow prevention is necessary to stop potentially contaminated or polluted water from entering the public water supply due to either a backpressure or backsiphonage event. Backflow prevention assembly tester or tester means a person who (i) holds a backflow prevention assembly tester license issued by the commission and (ii) is registered to test backflow prevention assemblies in the City of Denton on any domestic, commercial, industrial, or irrigation line. Backflow protection means protection against Backflow provided in accordance with this article, 30 Tex. Admin. Code § 290.44, and the Plumbing Code. In the case of a conflict between this article, state laws or rules, or the Plumbing Code, the more restrictive standard shall apply. Backpressure means any elevation of pressure in downstream piping (For example, and without limitation, by pump, elevation of piping, steam pressure, or air pressure) above the supply pressure at the point of consideration that would cause or tend to cause a reversal of the normal direction of flow. Backsiphonage means the flow of water or a mixture of water and other liquids, mixtures, or substances into the distribution pipes of the public water system from any source other than its intended source caused by a sudden reduction of pressure in the public water system. Building official means the official, or their designee, charged with the administration and enforcement of chapter 17 of the Code of the City of Denton, Texas. City means the City of Denton, Texas. Commission means the Texas Commission on Environmental Quality ("TCEQ") or its successor agency. Containment means a method of backflow prevention that requires the installation of a backflow prevention assembly at the service connection. Contaminant means any substance, whether organic, inorganic, radiological, or biological, that could degrade the quality of water in the public water system's distribution system and may endanger public health and safety. Cross-connection means any actual or potential connection or structural arrangement between the PWS and any other source or system through which it is possible to introduce to the PWS any used water, industrial fluid, gas, or substance other than potable water supply. The term "cross-connection" includes, but is not limited to, bypass arrangements, jumper connections, removable sections, swivel or change-over devices, and any other temporary or permanent devices. (1) The term "direct cross-connection" means a cross-connection that is subject to both backsiphonage and backpressure. (2) The term "indirect cross-connection" means a cross-connection that is subject to backsiphonage only. Cross-connection control assembly means an assembly: (1) Placed upon any connection, physical or otherwise, between the PWS and any plumbing fixture, tank, receptacle, equipment, or device; and (2) Designed to prevent contamination in any part of the PWS. Customer service inspection or cross-connection control inspection or CSI means an examination of the private water system by a commission licensed customer service inspector for the purpose of providing or denying water service. The inspection is limited to the identification and prevention of cross-connections, potential contaminant hazards, and illegal lead materials. Degree of hazard means either a health hazard or a non-health hazard derived from an assessment of materials or substances that may come in contact with the PWS as the result of a cross-connection. (1) Health hazard means a cross-connection, or any other situation, involving a contaminant. (2) Non-health hazard means a cross-connection, or any other situation, involving a pollutant. Director means the general manager of water utilities and street operations for the city or their designees charged with the administration and enforcement of this article. Domestic use means any use of water suitable for human consumption, sanitation, bathing, cooking, or other ordinary household purposes or for purposes normally associated with residential, commercial, or institutional establishments such as offices, schools, hospitals, and churches, where the water does not become part of a manufacturing or industrial process. Double check backflow prevention assembly or double check assembly or double check or DC means an assembly that consists of two (2) independently acting and approved check valves and two (2) tightly closing, resilient, and seated shutoff valves attached at each end of the assembly, fitted with properly located resilient seated test cocks. This assembly is only approved for use against non-health hazards. Double check detector backflow prevention assembly or double check detector or DCDA means an assembly composed of a line-size approved double check assembly with a bypass containing a water meter and an approved double check valve assembly. The meter shall register accurately for all rates of flow including, without limitation, low rates of flow up to two (2) gallons per minute. This assembly is only approved for use against non-health hazards. Double check detector backflow prevention assembly-Type II or DCDA-II means an assembly composed of a line-size approved double check assembly with a bypass around the second check containing a specific water meter and an approved double check valve assembly. The meter shall register accurately for all rates of flow including, without limitation, low rates of flow up to two (2) gallons per minute. This assembly is only approved for use against non-health hazards. Fire department connection or FDC means a fitting providing a point of connection for a fire department apparatus to supplement the water supply for standpipes, fire sprinkler systems, or other fire suppression systems within a premises. This connection typically includes one or more hose inlets with caps and a method of connection to the fire suppression system piping. Fire line tester means a tester who: (1) Is a full-time employee of an underground fire line contractor licensed by the Texas Department of Insurance; and (2) Meets the requirements for testers provided in this article. Hydrant means a City of Denton-owned device connected to the potable water supply, consisting of an upright pipe from the public water system with a valve and one or more outlets. Its purpose is to provide a point of access for drawing water for uses authorized and regulated by the city. Hydrant meter or stationary construction hydrant meter means a fixture: (i) owned, maintained, and installed by the City of Denton; (ii) composed of a meter and RP combination; and (iii) required at any connection to a hydrant. Mobile unit means any operation that may have the potential to introduce contaminants into a potable water supply from a mobile source. These operations include, but are not limited to, carpet-cleaning vehicles, water-hauling vehicles, street-cleaning vehicles, liquid-waste vehicles, power-wash operations, and pest control vehicles. New construction means: (1) Construction of any new building or structure; or (2) Construction that: a. Alters the plumbing of an existing building or structure; b. Requires an upsized meter or service line; c. Requires a permit under the International Codes adopted by the city and provided in the Code of the City of Denton, Texas; and d. Is associated with a pending permit application filed with the building safety department after April 7, 2026. Non-potable water supply means any water that does not meet the definition of "potable water supply." Non-residential use means any water use not included in the term "residential use", as defined in this article. Person means any individual, firm, partnership, joint venture, association, club, fraternal organization, joint stock company, corporation, cooperative, estate, trust, receiver, trustee, syndicate, or any other group or combination acting as a unit. Plumbing Code or PC means the International Plumbing Code adopted in the Code of the City of Denton Texas, chapter 28, article VII, as amended. Point-of-use isolation or internal protection means the appropriate backflow protection within the private water system at the point where an actual or potential cross-connection exists. Pollutant means an impairment of water quality that does not create a hazard to public health but does adversely and unreasonably affect the aesthetic qualities of such water for domestic use. Potable water supply means any water supply that is suitable for human consumption and meets the definition of drinking water in 30 Tex. Admin. Code § 290.38(25). Premises means all or any portion of any property, real or personal, to which water is provided including, without limitation, all improvements, mobile structures, buildings, private water systems, or other structures. This term also includes, but is not limited to, residential, commercial, industrial, and institutional premises. Pressure vacuum breaker backflow prevention assembly or pressure vacuum breaker or PVB means an assembly that provides protection against backsiphonage but does not provide adequate protection against backpressure backflow. The assembly is a combination of a single check valve with an AVB and can be used with downstream resilient seated shutoff valves. In addition, the assembly has suction and discharge gate valves and resilient seated test cocks that allow the full testing of the assembly. This assembly is only approved for protection against backsiphonage. Private water system means a water system, or any portion thereof, not owned or operated by the City of Denton. For the purposes of this article, a private water system begins downstream of the service connection. Public water system or PWS means the City of Denton's publicly owned water system and the potable water supply contained therein. This term includes all services, reservoirs, facilities, lines, and equipment associated with the production, treatment, storage, or conveyance of water for public consumption. Reclaimed water means wastewater collected and treated at a wastewater treatment plant to a quality that meets or exceeds the requirements of 30 Tex. Admin. Code Ch. 210, as amended, and the City of Denton's authorization pursuant to that chapter. Reclaimed water is not a potable water supply. Reclaimed water system means the City of Denton's publicly owned reclaimed water system and the reclaimed water contained therein. This term includes all services, reservoirs, facilities, lines, and equipment associated with the production, treatment, storage, or conveyance of reclaimed water for non-potable use. Reduced pressure backflow prevention assembly or RP means an assembly containing two (2) independently acting, approved check valves together with a hydraulically operated, mechanically independent pressure differential relief valve located between the check valves and below the first check valve. The assembly shall include properly located, resilient, and seated test cocks and tightly closing, resilient, and seated shutoff valves at each end of the assembly. Reduced pressure principal detector assembly type II or RPDA-II means a specially designed assembly composed of a line-size approved reduced pressure principal assembly with a bypass around the second check containing a specific water meter and an approved check valve. Reduced pressure principle detector backflow prevention assembly or reduced pressure zone detector assembly or RPZDA means a specifically designed assembly composed of a line-size approved, reduced pressure principal assembly with a bypass containing a specific water meter and an approved reduced pressure principal backflow prevention assembly. Regulatory authority means any of the following city officials: (i) the general manager of water utilities and street operations, or their designated representative, (ii) the City of Denton Building Official, or their designated representative, (iii) the City of Denton Fire Marshal, or their designated representative, or (iv) the city manager appointed department ordinance administrator, or their designee charged with the administration and enforcement of this article. City positions included in this definition include any individual holding any successor position of equal authority. Representative of the water system means a city employee who possesses a commission-issued customer service inspection license and is designated by the director to perform cross-connection control duties including, but not limited to, cross-connection control inspections. Residential use means water use by any person occupying a single-family dwelling or duplex. This term also includes housing or apartments where individual units are each on a separate meter or, in cases where two (2) units are served by one (1) meter, the units are full-time dwellings. Service connection means the point of connection between the public water system's distribution system and a private water system, typically at the water meter or property line, where the City of Denton relinquishes direct control over the water and means of conveyance. Spill resistant vacuum breaker backsiphonage prevention assembly or SVB means an assembly containing an independently operating, internally loaded check valve and an independently operating, loaded air inlet valve located on the discharge side of the check valve. Test report form means the standard form adopted and utilized by the director for the purpose of demonstrating a backflow prevention assembly's compliance with this article. This form is the only document deemed valid for recording and submitting official test results under this article. Thermal expansion means heated water that does not have the space to expand. Used water means water supplied by the PWS after it has passed through the service connection and is no longer under the PWS's control. User means any person who is an owner, tenant, or lessee of a premises receiving water service from the public water system. The term "user" may also include any agent of an owner, tenant, or lessee who is responsible for backflow prevention on a premises receiving water service from the public water system. If a word or term is not defined in this article, unless the context clearly indicates otherwise, it shall have the definition provided in the current edition of the Manual of Cross-Connection Control published by the Foundation for Cross-Connection Control and Hydraulic Research, University of Southern California. A copy of the Manual of Cross-Connection Control shall be kept on file in the office of the city secretary. All definitions that are singular also include the plural form of the term being defined. Named city positions include any applicable successor position.

(Ord. No. 25-1726, § 3(Exh. A), 3-24-26)

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.