Sec. 114.011 - Operations rules.

In operations under a permit the permittee or permittee's assigns must observe the following rules, and the failure to observe same shall be unlawful: (A) After any oil or gas well is brought into production, there shall be no storage or receiving tanks kept within the city limits, but the same shall be kept on the outside thereof. (B) In no event shall earthen slush or mud pits be dug or used within the city. (C) No field working tank having a capacity of 10,000 barrels or more shall hereafter be built nearer than 200 feet (measured from shell to shell) to any other like tank. (D) Printed signs reading: "DANGEROUS, NO SMOKING ALLOWED," or similar words, shall be posted in conspicuous places near each producing well, tank battery, and the like. (E) All permittees' premises shall be kept clear of high grass, weeds and combustible trash, within the fenced enclosure around an oil tank or producing well, or, if there is no fenced enclosure, within a radius of 25 feet around an oil tank or producing well. (F) Open earthen storage for oil is prohibited. (G) All oil tanks, where there is a gas hazard, shall be gas tight and provided with proper gas vents. (H) No open flame shall be placed inside the derrick of a well showing oil or gas. (I) All oil and gas pipelines laid upon or across a public road or highway must be buried to a reasonably safe depth. (J) Standard operating procedures under the applicable rules and regulations of the State Railroad Commission as well as those ordinary practices adhered to by prudent operators in this area shall be followed in: (1) The setting and cementing of surface casing and oil strings. (2) The testing of surface pipe and oil strings. (K) Two fluid-operated blowout preventers shall be used for all drilling or completion operations involving the use of drill pipe, casing or tubing after surface casing has been set. The mechanical operation of blowout preventers shall be tested at reasonable intervals and in addition they shall be tested with bump pressure frequently enough to insure good working order at all times. (L) All wells shall be equipped with wellhead assemblies and Christmas trees of working and test pressures as provided in applicable rules and regulations of the State Railroad Commission and in addition shall conform with standard practice and procedures used by prudent operators in this area. (M) No boiler or electric lighting generator shall be placed or remain nearer than 150 feet to any producing well or oil tank. (N) Any rubbish or debris that might constitute a fire hazard shall be removed to a distance of at least 100 feet from the vicinity of wells, tanks and pump stations. All wastes shall be disposed of in such manner as to avoid creating a fire hazard or polluting streams and fresh water strata. (O) All producing wells, pits and tank batteries shall be protected with a six-foot woven fence having a barbed wire guard at the top and a gate with lock. (P) Only portable slush tanks for mud or water shall be permitted in connection with the drilling and reworking operations. The tanks and their contents shall be removed from the premises and the drilling site within ten days after completion of the well. (Q) Motive power for all operations after completion of drilling operations shall be electric or properly muffled gas or gasoline engines. All pumping wells shall be equipped with electric motors gas lift facilities, or properly muffled gas or gasoline engines. (R) Permittee shall make adequate provisions for the disposal of all salt water or other impurities which such permittee may bring to the surface, such disposal to be made in such manner as not to contaminate the fresh water supply, present or prospective, or to injure surface vegetation. (S) In order to protect the fresh water sands which are the source of water supply for this city, the casing program of all wells drilled hereafter in this city not otherwise excepted from the terms of this subchapter shall include surface casing of new or reconditioned pipe. Fresh water sands to be protected are herein defined as those above a minimum depth of 850 feet or greater depth as stipulated by the Texas Natural Resource Conservation Commission or State Railroad Commission in the event special field rules are adopted. To protect fresh water, a permittee shall set surface casing to the depth stipulated by the Texas Natural Resource Conservation Commission or the State Railroad Commission, in the event special field rules are adopted, but in no instance to a depth less than 1,150 feet and cement with sufficient cement to fill the annulus from the casing set depth to the surface and provide return of uncontaminated cement at the surface. Cementing shall be by pump and plug method. Cement shall be allowed to stand a minimum of 12 hours under pressure and 24 hours before drilling plug or initiating test. After cementing, the surface casing shall be tested by pump pressure of at least 750 pounds per square inch. If at the end of 30 minutes the pressure shows a drop of 150 pounds per square inch or more, the casing shall be condemned. After the corrective operations the casing shall again be tested in the same manner. It is controllingly provided, however, that in the event a permittee can establish to the satisfaction of the City Council that the fresh water sands can be adequately protected by use of other means or measures, any or all of the foregoing requirements may be waived by the City Council. (T) Any and all the provisions of this subchapter may be waived by the City Council upon a showing by the permittee to the satisfaction of the City Council that the planned manner of operation by the permittee or the equipment to be used by the permittee will adequately protect the public health, safety and welfare.

(`82 Code, § 8-11) (Ord. 415, passed 3-3-70)

Ask a question about Edinburg law

Corpus searches the Edinburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.