Sec. 151.102 - Interceptors and mud traps.
Interceptors and mud traps shall comply with the provisions of Chapter VIII of the Standard Plumbing Code herein adopted and with designs furnished or approved by the city and shall empty into a storm sewer when deemed feasible and necessary by the Director of Public Works and the City Engineer. The drawings on file at the City Hall set out the requirements for motor vehicle wash racks. Interceptors or sedimentation tanks for industrial wastes shall be similar to the wash rack trap, except that they shall be sized at a ratio of 400 cubic feet of sludge capacity to each 10,000 gallons of liquid discharging into the sewer system per day. The outlets from sludge and outlet tanks shall be permanently screened with brass or bronze wire mesh not exceeding one-half inch openings. Further, the outlet tank shall be covered.
(`82 Code, § 6-113) (Ord. 341, passed 10-5-65)