For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 53.26 — Utility profile

Code of Ordinances of the City of Edinburg, Texas (Codified through Ordinance No. 2026-5214, enacted June 2, 2026 (Supp. No. 14)) · Edinburg Code of Ordinances § 53.26

Corpus is an independent public-information project, not the official City of Edinburg website. Stable reference: corpuslaw.us/code/75ae899d-d3ba-42c4-8103-f56f4d32cbc4

Sec. 53.26 - Utility profile.

(A) Demographics. The City of Edinburg provides water and wastewater services within Edinburg's city limits and extraterritorial jurisdiction. The water service area is approximately 278 square miles and the sewer service area is approximately 286 square miles. The estimated population served by the water system is 100,762. (B) Water Conservation Coordinator. The City of Edinburg Water Conservation Coordinator is the Director of Utilities or his/her designee. The conservation coordinator coordinates water utility staff, data from various departments, and other resources as necessary for the purpose of developing, implementing, and evaluating the effectiveness of the utility's water conservation plan. (C) Water Supply. Purchase of Raw Water. The Rio Grande River is the sole source of water for the citizens of Edinburg. The City of Edinburg currently owns/under contract up to 14,851.9645 acre-feet of water rights per year from Hidalgo County Irrigation District #1(HCID #1) and Hidalgo County Irrigation District #2 (HCID#2). In addition, the City went into an agreement with the City of McAllen to purchase a minimum of 55.24 acre-feet of treated potable water per year. The City of Edinburg receives raw water from both HCID #1 and #2 via irrigation canals and gravity pipes ranging from 30 inches—54 inches. After the water is received from the two irrigation districts, the raw water is stored in a city owned raw water reservoir, which has a maximum storage capacity of 210 million gallons (MG). The raw water is either diverted to the West Edinburg and the Downtown Water Treatment Plants through a series of pipes. Interconnections. The City of Edinburg distribution system is currently interconnected with the following entities: • City of McAllen—purchase treated water. • North Alamo Water Supply Corporation—purchase and selling of treated water. Capacity of Water Treatment Plant. The City of Edinburg currently owns and operates the following Water Treatment Plants: • West Edinburg Water Treatment Plant (Conventional Treatment Process)—Rated Capacity of 16 Million Gallons per Day (MGD). • Downtown Water Treatment Plant (Conventional Treatment Process)—Rated Capacity of Ten Million Gallons per Day (MGD). Both water treatment plants utilize chlorine dioxide and chloramines as disinfectants to provide safe potable drinking water to the City of Edinburg customers. Pumps and Storage Capacities. The water treatment plants have the following pumping and storage capacities: • West Edinburg Water Treatment Plant—Rated at 16 MGD's. ■ Raw—Five pumps rated at seven million gallons per day per pump. ■ High Service—Six pumps rated at seven million gallons per day per pump. ■ Storage—Two Ground Storage Tanks with a combined storage capacity of four million gallons. • Downtown Water Treatment Plant—Rated at ten MGD's. ■ Raw—Four pumps with pumping capacity that ranges from 2.5—8.4 million of gallons per day per pump. ■ High Service—Five pumps with pumping capacity that ranges from 1.2—8.5 million of gallons per day per pump. ■ Storage—Three underground clear wells with a combined storage capacity of 3.5 million gallons. • Booster Stations. ■ Trenton Booster Station—Two pumps with pumping capacity of 700 gallons per minute per pump and pumps directly into the distribution system. ■ West Booster Station—Four pumps with a pumping capacity of 2.2—4.3 million gallons per day per pump and has a combined storage capacity of 1.7 million gallons. ■ North Booster Station—Four pumps with a pumping capacity of 1.8 million gallon per pump and has a storage capacity of 400,000 gallons. • Elevated Storage. ■ North Water Tower—500,000 gallons. ■ South Water Tower—500,000 gallons. ■ West Tower—750,000 gallons. ■ Southwest Tower—1,000,000 gallons. ■ Cibolo Tower—400,000 gallons. Total combined storage of all facilities (GST's, clear wells & elevated storage) is 12.75 million gallons. The City of Edinburg has a total of 486 miles of water lines and 3,331 fire hydrants in the distribution system. (D) Water Use Characteristics. Water Pumpage. Current daily average pumpage for Treated water in 2023 was 13.148 MG, and metered water sales of 12.664 MG. Water Uses and Per Capita Water Use. The City of Edinburg supplies potable water for residential, commercial, industrial, and public uses. The estimated Total Gallons per Capita per Day (GPCD). The five-year average for Retail use for Edinburg is 138 GPCD (Source: TWDB Water Use Survey). Municipal per capita water use is total water pumped into the distribution system for residential, commercial, and public uses, divided by the population served. Industrial water use is not included in this calculation. Edinburg's five-year average for Municipal per capita use is 123 GPCD (Source: TWDB Water Use Survey). Edinburg's industrial users account for approximately less than three percent of the total active meter accounts. The two largest water volume users for 2023 were the Azteca Milling Company and the Calpine Hidalgo Energy. The table below displays the five-year and ten-year goal for water savings. Historic 5-yr Average | Baseline | 5-yr Goal for year 2028 | 10-yr Goal for year 2033 Total (GPCD) | 138 | 138 | 138 | 138 Residential (GPCD) | 78 | 78 | 78 | 78 Water Loss (GPCD) | 13 | 13 | 15 | 15 Water Loss (Percentage) | 9% | 9% | 11% | 11% Reference: TWDB Form No. 1964 Edinburg had approximately 31,488 active water meter accounts at the end of 2023 and is anticipated to increase on an annual basis. E. Unaccounted-For Water. Edinburg's unaccounted-for water is due to waterline breaks, leaks, meter underregistration, main line flushing, and unmetered fire hydrants. The amount of unaccounted-for water is determined by the difference between production and metered water sales. The average amount of unaccounted for water loss for the past five years was nine and four-tenths percent. F. Wastewater Services. The City of Edinburg operates a wastewater treatment plant located at 1202 N. "M" Road, Edinburg, Texas. The plant uses extended aeration under activated sludge process. The plant is authorized to treat up to 12.3 MGD. Plant expansion to upgrade to 12.3 MGD was completed in May 2013. The City is authorized to reuse the treated wastewater effluent for Los Lagos Golf Club, Edinburg Municipal Park, and the Calpine Electric Power Company. The annual five-year average of treated wastewater volume is 3.49 BG. The Edinburg Wastewater Treatment Plant currently has a 12.3 MGD designed capacity. The plant is currently operating under regular monitoring operation: CBOD 10.0 mg/L, TSS 15.0 mg/L and NH3 2.0 mg/L. The wastewater collection system consists of 418 miles of lines, with line sizes ranging from six inches to 36 inches. There are currently 52 lift stations and approximately over 26,232 active sewer accounts. The following is a description of the Edinburg Public Utilities System. G. WATER SUPPLY AND USE DATA. 2023 Data. Estimated Population: | 100,762 Water Source: Primary Source | Rio Grande River Raw Water Rights/Available Allotments | 14,851.9645 acre feet Raw Water Reservoir Capacity | 210 Million Gallons (MG) Water Production: Average Annual Pumpage (3-Year Average) | 4.573 BG Maximum Daily Treated Capacity (2023) | 16.337 MGD Average Daily Pumpage (3-Year Average) | 12.526 MGD Unaccounted-For Water | 7.6% (3-Year Average, from Reservoir to End-Users) | 387 MG/Year Treated Water Capacity Total Underground Storage | 3.500 MG Total Ground Storage Tank | 6.100 MG Total Elevated Storage | 3.150 MG Water Uses by Sector: (3-Year Average) Residential | 2,539 MG/Year Commercial | 1,356 MG/Year Industrial | 127 MG/Year Wastewater Production: Annual Amount Treated (3-Year Average) | 33,528 MG/Year Maximum Treated Capacity | 310.6 MGD Average Daily Treated | 39.4 MGD

(Am. Ord. No. 2024-4961, § II(Exh. A), passed 4-16-24)

Ask a question about Edinburg law

Corpus searches the Edinburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.