§ 18.18.070 — Shielding standards
El Paso City Code (Supp. No. 95, Update 4: codified through Ordinance No. 019889, enacted June 23, 2026) · El Paso City Code § 18.18.070
Corpus is an independent public-information project, not the official City of El Paso website. Stable reference: corpuslaw.us/code/39ce11e9-7a85-4bdd-b200-1424404ede33
18.18.070 - Shielding standards.
All nonexempt outdoor lighting fixtures shall have shielding as shown in Table 18.18.070. Table 18.18.070 LAMP TYPE AND SHIELDING STANDARDS1,2,3,4 LIGHTING ZONE USE CLASS AND LAMP TYPE | E4 | E3 | E2 | E1 Class 1 lighting (Color Rendition): Initial output greater than or equal to 1800 lumens | F | F | F | F Initial output below 1800 lumens (2) | A(1) | A(1) | A(1) | F Class 2 lighting (General Illumination): Initial output greater than or equal to 1800 lumens | F | F | F | F Initial output below 1800 lumens (2) | A(1) | A(1) | A(1) | F Class 3 lighting (Decorative)(3): Initial output greater than or equal to 1800 lumens | F | F | F | X Initial output below 1800 lumens (2) | A(1) | A(1) | A(1) | F Residential lighting (all Classes)(4): Initial output greater than or equal to 1800 lumens | F | F | F | F Initial output below 1800 lumens (2) | A(1) | A(1) | A(1) | A(1) Notes to Table 18.18.070 A = all types of light fixtures are allowed except that any spot or floodlight shall be aimed not higher than twenty-five degrees from the vertical line between the light fixture and the ground when light emitted from a light fixture is visible from any off-site residential property or public roadway. [image omitted; see the official code] Illustration of Note "A" F = only fully shielded light fixtures allowed X = not allowed 1. Flood or spot lamps shall be aimed no higher than twenty-five degrees from the vertical line between the light fixture and the ground when the source is visible from any off-site residential property or public roadway. Exception: seasonal decorations all be permitted in all lighting zones. 2. All class 3 lighting shall be extinguished between 11:00 p.m. (or when the business closes, whichever is later) and sunrise. 3. Residential refers to single family attached or detached uses located in any of the zone districts such as single-family detached and duplexes. Multiple-family residential uses, or apartments, must use standards for class 1, 2 and 3 lighting.
(Ord. 15996 § A (part), 2005) (Ord. 17171, § 5, 8-18-2009)
Ask a question about El Paso law
Corpus searches the El Paso sections it holds and shows the ones that match, with their citations. Free, no sign-in.