§ 18-383 — Design and installation; minimum requirements

Code of Ordinances, City of Frisco, Texas (Frisco City Code, Home Rule Charter and Code Appendix current through Ordinance 2026-10-64 adopted October 20, 2026 (eCode360 publication FR6313, scraped 2026-11-18)) · Frisco City Code § 18-383

Corpus is an independent public-information project, not the official City of Frisco website. Stable reference: corpuslaw.us/code/ecfa8646-bc3b-4385-b495-cd5104668dd5

§ 18-383: Design and installation; minimum requirements.

(a) Manufacturer's limitations. No irrigation design or installation shall require the use of any component, including the water meter, in a way which exceeds the manufacturer's published performance limitations for the component; and (b) Spacing. (1) The maximum spacing between emission devices must not exceed the manufacturer's published radius or spacing of the device(s). The radius or spacing is determined by referring to the manufacturer's published specifications for a specific emission device at a specific operating pressure. Turf area eight (8) feet or wider must have heads spraying back to achieve head to head coverage. (2) New irrigation systems or extensions of systems shall comply with article IV, section 2 of the Comprehensive Zoning Ordinance (Revised ZA06-0005). If pop-up sprays or rotary sprinkler heads are used in a new irrigation system, the sprinkler heads must direct flow away from any adjacent surface and shall not be installed closer than four inches from a hardscape, such as, but not limited to, a building foundation, fence, concrete, asphalt, pavers, or stones set with mortar. (3) Narrow paved walkways, jogging paths, golf cart paths or other small areas located in cemeteries, parks, golf courses or other public areas may be exempted from this requirement if the runoff drains into a landscaped area. (4) Each backflow prevention device must be located no more than three (3) feet from the water meter. In cases where RPZ or PVB assemblies are used, the device shall be located on the side of the building and integrated into the building envelope or consolidated into enclosed service areas and screened with primary building materials used on the building or living vegetative screens. (c) Water pressure. Emission devices must be installed to operate at the minimum and not above the maximum sprinkler head pressure as published by the manufacturer for the nozzle and head spacing that is used. Methods to achieve the water pressure requirements include either a city-approved pressure regulator or pressure-compensating heads. Commercial irrigation must use pressure-regulating heads on all turf heads. (d) Piping. Piping in irrigation systems must be designed and installed so that the flow of water in the pipe will not exceed a velocity of five feet per second for polyvinyl chloride (PVC) pipe. (e) Irrigation zones. Irrigation systems shall have separate zones based on plant material type, microclimate factors, topographic features, foundation protection, soil conditions, and hydrological requirements. All non-turf landscape areas shall be designed with drip irrigation to include pressure-compensating, non-draining emitters and a 120 mesh filter. Parkway areas within ten (10) feet from the curb must have either drip irrigation or high-efficiency, low-precipitation nozzles, as approved in writing by the city. No single stream rotors permitted in front yards unless approved in writing by the city. (f) Matched precipitation rate. Zones must be designed and installed so that all of the emission devices in that zone irrigate at the same precipitation rate. (g) No-spray surface. Irrigation systems shall not spray water over surfaces made of concrete, asphalt, brick, wood, stones set with mortar, or any other impervious material, such as, but not limited to, walls, fences, sidewalks, streets, etc. (h) Foundations. A separate station shall be dedicated only for drip irrigation for the purpose of watering a structure's foundation. (i) Master valve. A master valve shall be installed on the discharge side of the backflow prevention device on all new installations and located within twelve (12) inches of the backflow prevention device. (j) Check valves. Check valves are required where elevation differences may result in low head drainage. Check valves may be located at the sprinkler head(s) or on the lateral line. Any slope greater than a 4:1 ratio must be irrigated by drip irrigation. (k) Pop-up heads. Pop-up heads shall be installed and operated to extend above all landscape turfgrass. (l) PVC pipe primer solvent. All new irrigation systems that are installed using PVC pipe and fittings shall be primed with a colored primer prior to applying the PVC cement in accordance with the Uniform Plumbing Code (sec. 316) or the International Plumbing Code (sec. 605). (m) Irrigation controllers. All new irrigation systems must include an irrigation controller capable of providing the minimum following features: (1) Multiple irrigation programs with at least three start times per program; (2) Limiting the irrigation frequency to once every seven (7) days and once every fourteen (14) days; and (3) Water budgeting features. (n) Operational rain and freeze shut-off devices capable of setting thresholds for rain and freeze at or above 40 degrees. All new automatically controlled irrigation systems must include an operational sensor with the capability to set thresholds for both rain and freezing temperatures at or above 40 degrees or other technology designed to inhibit or interrupt operation of the irrigation system during periods of freezing weather at or above 40 degrees and rainfall. Freeze and rain shut-off technology must be installed according to the manufacturer's published recommendations. Repairs to existing automatic irrigation systems that require replacement of an existing controller must include an operational sensor with the capability to set thresholds for both rain and freezing temperatures at or above 40 degrees or other technology designed to inhibit or interrupt operation of the irrigation system during periods of freezing weather at or above 40 degrees and rainfall. (o) Isolation valve. All new irrigation systems must include an isolation valve between the water meter and the backflow prevention device. (p) Depth coverage of piping. Piping in all irrigation systems must be installed according to the manufacturer's published specifications for depth coverage of piping. (1) If the manufacturer has not published specifications for depth coverage of piping, the piping must be installed to provide minimum depth coverage of six inches of select backfill, between the top of the pipe and the natural grade of the topsoil. All portions of the irrigation system that fail to meet this standard must be noted on the irrigation plan. If the area being irrigated has rock at a depth of six inches or less, select backfill may be mounded over the pipe. Mounding must be noted on the irrigation plan and discussed with the irrigation system owner or owner's representative to address any safety issues. (2) If a utility, manmade structure or roots create an unavoidable obstacle, which makes the six-inch depth coverage requirement impractical, the piping shall be installed to provide a minimum of two inches of select backfill between the top of the pipe and the natural grade of the topsoil. (3) All trenches and holes created during installation of an irrigation system must be backfilled and compacted to the original grade. (q) Wiring irrigation systems. (1) Underground electrical wiring used to connect an irrigation controller to any electrical component of the irrigation system must be listed by Underwriters Laboratories as acceptable for burial underground. (2) Electrical wiring that connects any electrical components of an irrigation system must be sized according to the manufacturer's recommendation. (3) Electrical wire splices which may be exposed to moisture must be waterproof as certified by the wire splice manufacturer. (4) Underground electrical wiring that connects an irrigation controller to any electrical component of the irrigation system must be buried with a minimum of six (6) inches of select backfill. (r) Water contained within the piping of an irrigation system is deemed to be non potable. No drinking or domestic water usage, such as, but not limited to, filling swimming pools or decorative fountains, shall be connected to an irrigation system. If a hose bib (an outdoor water faucet that has hose threads on the spout) is connected to an irrigation system for the purpose of providing supplemental water to an area, the hose bib must be installed using a quick coupler key on a quick coupler installed in a covered purple valve box and the hose bib and any hoses connected to the bib must be labeled "Non Potable, Not Safe For Drinking." An isolation valve must be installed upstream of a quick coupler connecting a hose bib to an irrigation system. (s) Beginning January 1, 2010, either a licensed irrigator or a licensed irrigation technician shall be onsite at all times while the landscape irrigation system is being installed. When an irrigator is not onsite, the irrigator shall be responsible for ensuring that a licensed irrigation technician is onsite to supervise the installation of the irrigation system.

( Ordinance 08-12-103 , sec. 2(18-382), adopted 12/2/08 ; Ordinance 17-12-83 adopted 12/5/17 )

Ask a question about Frisco law

Corpus searches the Frisco sections it holds and shows the ones that match, with their citations. Free, no sign-in.