§ 38-112: Deletions and additions.

The following deletions and additions to the 2016 NFPA 13 are approved and adopted (deletions are evidenced by strikethrough and additions are evidenced by underline): Chapter 6: System Components and Hardware of the 2016 NFPA 13 is amended as follows: Section 6.6 Valves of the 2016 NFPA 13 is amended as follows: 6.6.1.3.2 A listed water control valve assembly with a reliable position indication connected to a remote supervisory station shall be permitted. Valves on connections to water supplies, sectional control and isolation valves, and other valves in supply pipes to sprinklers and other fixed water-based fire suppression systems shall be supervised in accordance with the current International Fire Code, as adopted and amended by the Frisco City Council. Section 6.7 Fire Department Connections of the 2016 NFPA 13 is amended as follows: 6.7.1.3 [Entire subsection deleted.] 6.7.2 [Entire subsection deleted.] 6.7.2 Fire Department connections shall be equipped with listed Knox locking caps, properly secured and arranged for easy removal by fire departments. Section 6.8 Waterflow Alarm Devices of the 2016 NFPA 13 is amended as follows: 6.8.3.1 [Entire subsection deleted.] 6.8.3.1 An alarm unit shall include a listed mechanical alarm. No electrically operated appliance shall be used. Chapter 8: Installation Requirements of the 2016 NFPA 13 is amended as follows: Section 8.15 Special Situations is amended to read as follows: 8.15.5.3 and Items 1-5 [Entire subsection deleted.] 8.15.5.3 Automatic sprinklers shall be installed in elevator machine rooms and elevator machine spaces. Automatic sprinklers shall be installed in elevator hoistways where combustible materials are present or the elevator shaft is constructed of combustible construction. 8.15.7.1 Unless the requirements of 8.15.7.2, 8.15.7.3, or 8.15.7.4 are met, sprinklers shall be installed under exterior roofs, canopies, porte-cocheres, balconies, decks, or similar projections exceeding 4 ft. (1.2m) in width. Sprinklers must be provided beneath exterior roofs, canopies, porte-cocheres, balconies, decks or similar projections when a vehicle or truck can stop or park beneath the roof, canopy, porte-cochere, balcony, deck or similar projection, regardless of construction type of the structure. 8.15.7.2 [Entire subsection deleted.] 8.15.7.3 [Entire subsection deleted.] 8.15.7.5 Sprinklers shall be installed under exterior projections greater than 2 ft (0.6 m) wide over areas where combustibles are stored or present. Dining establishments must have sprinklers provided beneath the projection where seating is provided. 8.15.8.1.1 [Entire subsection deleted.] 8.15.8.1.1 Sprinklers are required in all bathrooms regardless of construction type and/or size. 8.15.8.2* [Entire subsection deleted.] 8.15.8.2* Sprinklers are required in all clothes closets, linen closets, and pantries within dwelling units regardless of size or construction type. Section 8.16 Piping Installation is amended as follows: 8.16.1.1.2.1 [Entire subsection deleted.] 8.16.1.1.2.1 Valves on connections to water supplies, sectional control and isolation valves, and other valves in supply pipes to sprinklers and other fixed water-based fire suppression systems shall be supervised in accordance with the current International Fire Code, as adopted and amended by the Frisco City Council. Section 25.2.1.8 Hydrostatic Test is amended as follows[Entire subsection deleted.]: 25.2.1.8 When systems are being hydrostatically tested, tests shall be permitted to be conducted with pendent or horizontal sidev1all sprinklers or plugs installed in fittings. Any plugs shall be replaced with pendent or horizontal sidev1all sprinklers after the test is completed.

( Ordinance 00-12-16 , sec. 2, adopted 12/19/00 ; Ordinance 15-06-38 , sec. 4, adopted 6/16/15 ; Ordinance 17-11-76 adopted 11/7/17 ; Ordinance 19-11-112 adopted 11/19/19 )

Ask a question about Frisco law

Corpus searches the Frisco sections it holds and shows the ones that match, with their citations. Free, no sign-in.