§ 4.03.08 — Screening for Utilities, Mechanical, and Service Facilities
Code of Ordinances, City of Frisco, Texas (Frisco City Code, Home Rule Charter and Code Appendix current through Ordinance 2026-10-64 adopted October 20, 2026 (eCode360 publication FR6313, scraped 2026-11-18)) · Frisco City Code § 4.03.08
Corpus is an independent public-information project, not the official City of Frisco website. Stable reference: corpuslaw.us/code/5af359fb-67b1-4c38-903a-00a4376bec5d
§ 4.03.08: Screening for Utilities, Mechanical, and Service Facilities.
(A) Applicability. The following standards shall apply to all utility meters and associated apparatus associated with nonresidential, multifamily development and amenity centers for single-family developments. (B) Ground-mounted equipment screening. (1) Ground-mounted utility meters and other utility apparatus, including transformers shall be located to the rear of the structure or to the side of the structure in a designated utility or service yard. (2) No pedestrian pathway or pedestrian common space shall be located between the main structure and the utility meters/apparatus. (3) All transformers shall be screened from the view of streets, sidewalks, walking paths, bicycle paths, and adjacent properties with landscape hedge/trees or other green material that obscures the visibility of the equipment. (4) Ground-mounted utility and other utility apparatus, including transformers, shall be screened from the view of streets, sidewalks, walking paths, bicycle paths, and adjacent properties. Screening shall meet minimum clearances required by affected utility companies. Permitted screening methods include: a. Landscaping, including trees or evergreen shrubbery that materially obscures the visibility of the equipment. 1. All 3-phase transformers shall be screened with evergreen shrubs, minimum of six (6) foot height at time of planting. 2. All single-phase transformers shall be screened with evergreen shrubs, minimum four (4) foot height at time of planting. Indicate on the plans the location of all transformers and utility boxes. b. Masonry walls constructed of the same materials and color used in the primary building. c. Tubular steel in conjunction with evergreen shrubbery. d. Other material subject to review and approval of the Director of Development Services consistent with the intent of this subsection. e. All approved screening methods shall be one (1) foot above the height of the utility box. (C) Roof-mounted mechanical equipment screening. (1) All mechanical equipment shall be screened from view from ground level. (2) Where a parapet does not accomplish the intended screening, a screening wall equal to the height of the equipment shall be provided. (3) Mechanical penthouses shall be integrated into the building's overall design using, but not limited to, ornamental elements, cohesive rooflines, opaque materials, glazing, and latticework cladding. (4) In all cases, screening shall be compatible building materials. (5) Mechanical penthouses shall complement overall building design. (D) Finish of accessory elements. Exposed conduit, ladders, utility boxes, and drain spouts shall be: (1) Painted to match the color of the building or an accent color.
( Ordinance 2021-07-47 adopted 7/6/21 ; Ordinance 2024-05-21 adopted 5/7/2024 )
Ask a question about Frisco law
Corpus searches the Frisco sections it holds and shows the ones that match, with their citations. Free, no sign-in.