§ 4.05.05: Method of Measurement.

(A) Light measuring meter. (1) The light measuring meter shall have a color and cosine-corrected sensor with multiple scales and shall read within an accuracy of plus or minus five (5) percent. (2) It shall be tested, calibrated, and certified by an independent commercial photometric laboratory or the manufacturer within one (1) year of its use. (B) Measurements/readings. (1) Illumination levels shall be measured in footcandles with a meter sensor in a horizontal position at an approximate height of three (3) feet above grade. (2) Maximum illumination readings are to be taken directly beneath the luminaires.