§ 22.116: Grease inceptors required for food establishments.
(A) Unless a facility sells only prepackaged food, grease traps, interceptors, or separators are required at new food establishments and existing food establishments that change ownership. (B) Grease traps, interceptors, or separators shall be: (1) Adequately sized by a professional engineer, master plumber, or architect; (2) Installed and maintained in accordance with the Plumbing Code; (3) Located outside of the building footprint; and (4) Easily accessible for cleaning. (C) Cleaning schedules: (1) Grease traps and grease interceptors shall be cleaned as often as necessary to ensure that sediment and floating materials do not accumulate to impair the efficiency of the grease trap/interceptor; to ensure the discharge is in compliance with local discharge limits; and to ensure no visible grease is observed in discharge. (2) Grease traps and grease interceptors subject to these standards shall be completely evacuated a minimum of every 90 days, or more frequently when: (a) 25 percent or more of the wetted height of the grease trap or grease interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils or greases; (b) The discharge exceeds BOD, COD, TSS, FOG, pH, or other pollutant levels established by the City; or (c) If there is a history of non-compliance. (3) Any person who owns or operates a grease trap/interceptor may submit to the City Health Department a request in writing for an exception to the 90 day pumping frequency of their grease trap/interceptor. The City Health Department may grant an extension for required cleaning frequency on a case-by-case basis when: (a) The grease trap/interceptor owner/operator has demonstrated the specific trap/interceptor will produce an effluent, based on defensible analytical results, in consistent compliance with established local discharge limits such as BOD, TSS, FOG, or other parameters as determined by the City; or (b) Less than 25 percent of the wetted height of the grease trap or grease interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils, or greases. In any event, a grease trap and grease interceptor shall be fully evacuated, cleaned, and inspected at least once every 180 days.
( Ordinance 7598 adopted 7/8/2025 )
Ask a question about Garland law
Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.