§ 31.104 — Provisions for flood hazard reduction
Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Code of Ordinances § 31.104
Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/f0351877-8d77-4f44-90fd-e6be06a00208
§ 31.104: Provisions for flood hazard reduction.
(A) General standards. In all areas of special flood hazards, the following provisions are required for all new construction and substantial improvements: (1) All new construction or substantial improvements shall be designed (or modified) and adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; (2) All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage; (3) All new construction or substantial improvements shall be constructed with materials resistant to flood damage; (4) All new construction or substantial improvements shall be constructed with electrical, heating, ventilation, plumbing, and air-conditioning equipment and other service facilities that are designed or located with the minimum required freeboard set forth in sections 31.104(B) and 31.104(D) so as to prevent water from entering or accumulating within the components during conditions of flooding; (5) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system; (6) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the system and discharge from the systems into floodwaters; and (7) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. (B) Specific standards. In all areas of special flood hazards where base flood elevation data has been provided as set forth in section 31.102(B), section 31.103(B)(8), or subsection (C)(3), the following provisions are required: (1) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated two (2) feet above the base flood elevation. The bottom of all associated machinery and equipment shall be elevated a minimum of one (1) foot above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in section 31.103(C)(1)(a), is satisfied. (2) Nonresidential construction. New construction and substantial improvements of any commercial, industrial, or other nonresidential structure shall either have the lowest floor (including basement) elevated two (2) feet above the base flood level or, together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capacity of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop and review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed shall be maintained by the floodplain administrator. (3) Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: (a) A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. (b) The bottom of all openings shall be no higher than one foot above grade. (c) Openings may be equipped with screens, louvers, valves, or the coverings or devices provided that they permit the automatic entry and exit of floodwaters. (4) Manufactured homes. (a) All manufactured homes to be placed within zone A shall be installed using methods and practices which minimize flood damage. For the purpose of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. (b) All manufactured homes, including machinery and equipment, shall be elevated in compliance with subsection (1) above. (c) All manufactured homes to be placed or substantially improved within zones A1-30, AH and AE on the FIRM shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is two (2) feet above the base flood elevation; and be securely anchored to an adequately anchored foundation system in accordance with the provision of subsection (a) above. (5) Recreational vehicles. Recreational vehicles placed on sites within zones A1-30, AH, and AE on the flood insurance rate maps either: (a) be on the site for fewer than 1809 consecutive days; or (b) be fully licensed and ready for highway use; or (c) meet the permit requirements of section 31.103(C)(1) and the elevation and anchoring requirements for manufactured homes in subsection (4) above. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices, and has no permanently attached additions. (6) Lowest finished floor elevations. Any requirement contained in this article regarding the certification of the lowest finished floor elevation of a building or structure shall mean the as-built elevation of the building or structure. A certification based upon construction plans shall only be valid during the course of construction and an as-built certification shall be submitted upon the completion of construction. The certification shall be in the form prescribed by the Federal Emergency Management Agency under the National Flood Insurance Program. (C) Standards for subdivision proposals. (1) All subdivision proposals, including manufactured home parks and subdivisions shall be consistent with section 31.100(B), (C), and (D) of this article. (2) All proposals for the development of subdivisions, including manufactured home parks and subdivisions, shall meet development permit requirements of section 31.102(D), section 31.103(C), and the provisions of this section. (3) Base flood elevation data shall be generated for subdivision proposals and other proposed development including manufactured home parks and subdivisions, which contain greater than 30 lots or 3 acres, whichever is less, if not otherwise provided pursuant to section 31.102(B) or section 31.103(B)(8) of this article. (4) All subdivision proposals, including manufactured home parks and subdivisions, shall have adequate drainage provided to reduce exposure to flood hazards. (5) All subdivision proposals, including manufactured home parks and subdivisions, shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize or eliminate flood damage. (D) Standards for areas of shallow flooding (AO/AH zones). Located within the areas of special flood hazard, established in section 31.102(B), are areas designated as shallow flooding. These areas have special flood hazards associated with base flood depths of one (1) to three (3) feet where a clearly defined channel does not exist and where the path of flooding is unpredictable and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following provisions apply: (1) All new construction and substantial improvements of residential structures shall have the lowest floor (including basement, machinery, and equipment) elevated above the highest adjacent grade a minimum of one (1) foot higher than the depth number specified in feet on the FIRM (at least three (3) feet if no depth number is specified). (2) All new construction and substantial improvements of nonresidential structures: (a) Shall have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM (at least two (2) feet if no depth number is specified); or (b) Together with attendant utility and sanitary facilities shall be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. (3) A registered professional engineer or architect shall submit a certification to the floodplain administrator that the standards of this section, as proposed in section 31.103(C)(1)(a), are satisfied. (4) Within zones AH or AO adequate drainage paths shall be provided around structures on slopes, to guide floodwaters around and away from proposed structures. (E) Floodways. Portions of the areas of special flood hazard, established in section 31.102(B), are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions shall apply: (1) The placement of any manufactured home within the floodways is prohibited. Other encroachments are prohibited, including fill, new construction, substantial improvements and other development unless certification by a professional registered engineer is provided demonstrating that encroachments shall not result in any increase in flood levels within the community during the occurrence of the base flood discharge. (2) If subsection (1) above is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this section. (F) Penalties for noncompliance. No structure or land shall hereafter be constructed, located, extended, converted or altered without full compliance with the terms of this article and other applicable regulations. Violation of the provisions of this article by failure to comply with any of its requirements (including violations of conditions and safeguards established in connection with conditions) shall constitute a misdemeanor. Any person who violates this article or fails to comply with any of its requirements shall upon conviction thereof be fined not more than $500.00 for each violation and in addition shall pay all costs and expenses involved in the case. Nothing herein contained shall prevent the City from taking such other lawful action as is necessary to prevent or remedy any violation.
( Ordinance 4078 , sec. 1, adopted 3/10/87 ; Ordinance 4717 , sec. 1, adopted 10/19/93 ; Ordinance 6707 , sec. 1, adopted 6/17/14 ; Ordinance 7349 adopted 8/2/22 )
Ask a question about Garland law
Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
