For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 32.04 — Required standards

Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Code of Ordinances § 32.04

Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/811902fb-ebad-4dc3-9991-8bd9f7640269

§ 32.04: Required standards.

(A) Room, space and floor area. (1) Ceiling heights. (a) Habitable space shall have a ceiling height of not less than seven (7) feet except as otherwise permitted in this section. Kitchens, halls, bathrooms and toilet compartments shall have a ceiling height of not less than seven (7) feet measured to the lowest projection from the ceiling. Where exposed beam ceiling members are spaced at less than forty-eight (48) inches on center, ceiling height shall be measured to the bottom of those members. Where exposed beam ceiling members are spaced at forty-eight (48) inches or more on center, ceiling height shall be measured to the bottom of the deck supported by those members provided that the bottom of the members is not less than seven (7) feet above the floor. (b) In a room with a sloping ceiling, the prescribed ceiling height for the room is required in only one-half the area thereof. No portion of a room measuring less than five (5) feet from the finished floor to the finished ceiling shall be included in any computation of the minimum area thereof. In a room with furred ceiling, the prescribed ceiling height is required in two-thirds of the area thereof, but in no case shall the height of the furred ceiling be less than seven (7) feet. (2) Floor area. (a) Floor area. Every dwelling unit shall have at least 150 square feet of habitable floor area for the first occupant and 100 square feet of habitable floor area for each additional occupant. Except for kitchens, habitable rooms shall have an area of not less than 70 square feet. Where more than two persons occupy a room used for sleeping purposes the required floor area of 70 square feet shall be increased at the rate of fifty square feet for each occupant in excess of two. (b) Nothing in this subsection shall prohibit the use of an efficiency living unit within a multifamily dwelling that meets the following requirements: (i) The unit shall have a living room of not less than two hundred twenty (220) square feet of habitable floor area. An additional one hundred (100) square feet of floor area shall be provided for each occupant of such unit in excess of two (2). (ii) The unit shall be provided with a separate closet. (iii) The unit shall be provided with a kitchen sink, cooking appliances and refrigeration facilities each having a clear working space of not less than thirty (30) inches in front. (iv) The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower. (3) Width. No habitable room other than a kitchen shall be less than seven (7) feet in dimension. Each water closet stool shall be located in a clear space not less than thirty (30) inches in width. A clear space in front of the water closet stool of not less than twenty-four (24) inches shall be provided. (4) Capacity. A dwelling unit shall not be occupied by more persons who are unrelated to the first person listed on the deed as the owner (or first signatory on the lease if the property is leased) by blood, adoption or marriage, than the greater of (i) three unrelated persons in addition to the owner or first signatory on the lease; or (ii) to the extent that the dwelling unit contains sleeping rooms with a minimum floor area of 70 square feet, the number of persons who may occupy the dwelling unit shall be no less than one person per sleeping room; provided further that, to the extent that for each sleeping room containing an additional 50 square feet of floor area in addition to the minimum, one additional occupant for each additional 50 square feet shall be permitted, with the exception of: (a) Children who are related to an occupant of the dwelling unit by blood, adoption, or marriage within two degrees of affinity or consanguinity; and (b) Minor children who occupy the dwelling unit as a lawfully placed foster child. (B) Light and ventilation. (1) Natural light and ventilation. All habitable rooms within a dwelling unit shall be provided with natural light by means of exterior glazed openings with an area not less than the greater of one-tenth of the floor area of such room or ten (10) square feet. All bathrooms, water closet compartments, laundry rooms and similar rooms shall be provided with natural ventilation by means of operable exterior openings with an area not less than the greater of one-twentieth of the floor area of such room or one and one-half (1-1/2) square feet. All habitable rooms within a dwelling unit shall be provided with natural ventilation by means of operable exterior openings with an area of not less than the greater of one-twentieth of the floor area of such room or five (5) square feet. (2) Origin of light and ventilation. Required exterior openings for natural light and ventilation shall open directly onto a street or public alley or a yard or court located on the same lot as the building or when allowed by other law. Required exterior openings may open into a roofed porch where the porch: (a) Abuts a street, yard or court; (b) Has a ceiling height of not less than seven (7) feet; and (c) Has a longer side at least sixty-five (65) percent open and unobstructed. A required exterior opening in a room may open into a vent shaft which is open and unobstructed to the sky and not less than (4) feet in least dimension. No vent shaft shall extend through more than two (2) stories. For the purpose of determining light and ventilation requirements, any room may be considered as a portion of an adjoining room when one-half of the area of the common wall is open and unobstructed and provides an opening of not less than one-tenth of the floor area on the interior room or twenty-five (25) square feet, whichever is greater. (3) Mechanical ventilation. In lieu of required exterior openings for natural ventilation, a mechanical ventilation system may be provided. Such system shall be capable of providing two (2) air changes per hour in all habitable rooms and in public corridors. One-fifth of the air supply shall be taken from outside. In bathrooms, water closet compartments, laundry rooms and similar rooms, a mechanical ventilation system shall be connected directly to the outside and shall be capable of providing five (5) air changes per hour. (4) Hallways. All public hallways, stairs and other exit ways shall be adequately lighted at all times in accordance with the requirements of the Building Code. (C) Sanitation. (1) Dwelling units. Every dwelling unit shall be provided with a bathroom equipped with facilities consisting of a water closet, lavatory and either a bathtub or shower. (2) Kitchen. Every dwelling unit shall be provided with a kitchen and kitchen sink. Wooden sinks or sinks of similarly absorbent material are prohibited. (3) Fixtures. All plumbing fixtures shall be connected to a sanitary sewer or to an approved private sewage disposal system. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water under adequate pressure necessary for normal operation. All tubs, lavatories and commodes shall be of an approved glazed earthenware type or of a similar approved nonabsorbent material. (4) Room separations finish. Every water closet, bathtub or shower required by this article shall be installed in a room which will afford privacy to the occupant. A room in which a water closet is located shall be separated from food preparation or food storage rooms. Every bathroom shall have an approved moisture-resistant finish on the flooring or subflooring. (5) Floor coverings. When in the opinion of the City, the floor covering of a dwelling unit, which is leased or rented to a party other than the owner, is in a condition that normal cleaning will not reduce mold spore and bacterial concentrations to safe levels, the floor covering shall be replaced with new floor covering which conforms to the currently adopted version of the International Building Code. (D) Mechanical requirements. (1) Heating. Every dwelling unit shall be provided with approved heating facilities in operating condition capable of maintaining a room temperature of seventy-one (71) degrees Fahrenheit at a point three (3) feet above the floor in all habitable rooms. (2) Electrical power. If electrical power is available, the dwelling unit shall be connected to such electrical power. Every habitable room shall contain at least two (2) supplied electrical convenience outlets or one (1) convenience outlet and one (1) supplied electrical light fixture. Every bathroom, laundry room, and public hallway shall contain at least one (1) supplied electric light fixture. Electric circuits and outlets shall be maintained in operating condition and shall be sufficient to safely carry a load consistent with the standards contained in the version of the National Electrical Code most recently adopted by the City. (3) Water heaters. All water heaters shall be installed in accordance with the Plumbing Code and shall be provided with an over-temperature safety device manufactured, listed and installed in accordance with applicable nationally recognized safety standards for such devices. Every water heater shall have a discharge line the same diameter as the outlet and shall drain to the exterior of the building. If it is not reasonably possible to drain the discharge line to the exterior of the building, the line shall terminate not less than six (6) inches nor more than eight (8) inches from the floor. No water heater which depends upon direct combustion of fuel for heat shall be installed in any room used for sleeping or in a bathroom, nor in any closet or other confined space opening into a sleeping room or bathroom. In buildings constructed prior to the adoption of this section, the water heater may be installed in any location as long as approved safety dividers or shields are properly in place for the water heater and the installation does not create an additional hazard. (4) Ventilation for fuel-burning devices. Each heating and cooking device that burns solid fuel shall be properly connected to a chimney or flue. Chimney, flue and vent attachments shall be maintained in operating condition. (5) Air conditioning. (a) Refrigerated air equipment shall be provided in any dwelling unit or lodging room that is occupied by, rented or leased to a party other than the owner and shall be maintained in operable condition and must be capable of maintaining the inside of the dwelling unit or lodging room at a comfortable temperature zone, not to exceed a maximum temperature of 81 degrees Fahrenheit from May 1 through October 1. (b) It shall be an affirmative defense to this section if the outdoor ambient temperature exceeds 101 degrees Fahrenheit and the indoor ambient temperature can be maintained at no less than 20 degrees below the outdoor ambient temperature. (6) Each owner of a multifamily dwelling or lodging establishment which utilizes a cooling tower as a functional portion of an HVAC system shall, at the owner’s expense, perform annual testing of the cooling tower for the presence of Legionella pneumophila. The testing shall be performed by a third-party entity using analytical and collection procedures approved by the City. In the event that the property owner cannot provide a proper sampling technique, the property owner, on a form provided for such use by the City, may request that the sample be obtained and tested by the City Health Department and reimburse same for incurred expenses. The owner shall provide the laboratory test report to the City within 10 days of receipt for negative results and within 48 hours of receipt for positive test results. (7) When, in the opinion of the City, there is epidemiologic, microbiological, or physical evidence of the presence of a bacterial or fungal pathogen within the water supply, cooling tower(s), or HVAC system of a multifamily dwelling, the owner shall, at the owner’s expense, utilize a third-party testing entity and perform tests for human pathogens. The owner shall test for any pathogens specified by the City utilizing analytical procedures approved by the City. The owner shall provide the original document of the test results to the City within 48 hours of receipt by the owner. (E) Exits. (1) Every dwelling unit shall have access directly to the outside or to a public corridor. (2) Every sleeping room below the fourth story shall have at least one operable window or exterior door for emergency egress. The window or exterior door shall be operable from inside the dwelling without the use of tools or separate devices. All required egress windows and doors shall have the following minimum dimensions: (a) (i) A minimum net clear opening of five square feet on the first floor and five and seven-tenths square feet on the second and higher floors; (ii) A minimum net clear opening height of twenty-four inches; (iii) A minimum net clear opening width of twenty inches; and (iv) If the required opening is a window, a finished sill height of not more than forty-four inches above the floor; or (b) The minimum dimensions required by law applicable at the time the dwelling was constructed. (F) Lodging establishments. All of the provisions of this section apply to lodging establishments with the exception of subsections (A)(2), (A)(4), (B)(1), (B)(2), and (C)(2). The following additional standards shall apply to lodging establishments but do not apply to single-family or multifamily dwellings unless required by another provision of this Code: (1) Furnishings shall be maintained in good condition and clean. Furnishings with excessive wear, tears, or stains shall be replaced. (2) After each occupancy, the guest room shall be vacuumed, the linens in the guest room shall be replaced with clean linens, smooth surfaces on all fixtures shall be cleaned and sanitized, and trash shall be removed from the room. Glasses, pitchers, ice buckets, coffee pots, and eating and cooking utensils (other than disposable, single-use utensils) shall be cleaned and sanitized. (3) All rooms, furnishings, and bedding shall be free from an accumulation or infestation of insects or ectoparasites. If a lodging room becomes infested with insects of any type, the room shall not be occupied until the infestation is controlled. Lodging establishments shall, at a minimum, perform monthly pest control for all lodging rooms, or at more frequent intervals as required by the Director, in order to prevent infestation. Records of pest control treatments shall be made available for review on request by the Director. (4) Soap shall be provided in every lodging room by means of dispensed liquid or with new, individually wrapped bar soap. Used bar soap shall be removed from the lodging room when the guest ends the occupancy. Other toiletries provided by the lodging establishment which have been opened by the guest shall be removed when the guest ends the occupancy. Used soap and toiletries shall be discarded and shall not be used for any other purpose. A dispensed liquid soap shall be provided in all common and public bathrooms and toilets. (5) Single service utensils and single service articles shall be replaced after each occupancy when visibly damaged or evidence of tampering or contamination exists. (6) Ice provided to guests in any manner shall be produced only from potable water. Ice machines shall be free from visible trash and sediment. Ice shall not be made or stored in an owner’s or manager’s private refrigerator or private living areas. Ice that is not produced at the lodging establishment shall be obtained from an approved source and shall be properly labeled and protected from contamination during transportation and storage. Ice machines shall be of sanitary, durable, corrosion-resistant, and easily cleanable construction. Ice machines shall be kept sanitized and in good repair. Ice storage bins shall be drained into an approved sewage system and must have a physical air gap. When replacement of a self-service ice machine becomes necessary or additional machines are added, an automatic self-serve ice dispensing machine shall be installed instead. Ice machines shall be located in a place that provides protection from the elements and possible sources of contamination. Exterior ice machine locations shall have, at a minimum, overhead protection. The area shall be kept clean and shall be free of accumulation of excessive moisture, drippage, or trash. An ice machine with a storage bin for ice shall be equipped with an ice scoop that is attached to the ice bin with a tether of easily cleanable material. The tether shall be of such a length to prevent the scoop from touching the ground and shall be maintained in a clean and sanitary condition. (7) Lodging rooms shall be provided with clean linens for every bed in the room and enough towels for at least two occupants. All linens, towels, and laundry provided to a guest shall be provided in a clean, sanitary condition without excessive stains or damage. During laundering, clean linens, towels, and laundry shall be kept in separate carts and stored away from soiled linens, towels, and laundry. Clean linens, towels, and laundry shall be protected from dust, dirt, vermin, or other contamination. (8) Lodging establishments with non-guest laundry facilities shall use the laundry only for the washing and drying of linens, towels, uniforms, and aprons necessary to the operation of the lodging establishment; other uses of the laundry are prohibited. Laundry equipment such as washers and dryers shall be of commercial-grade and shall be installed and used according to manufacturer’s instructions and specifications. Laundry facilities shall be separated from any other permanent living quarters by complete partitioning and solid self-closing doors. Traffic through or use by guests of a non-guest laundry facility is prohibited. Laundry facilities for the use of guests, if provided, shall be located separate from non-guest laundry facilities. Guest laundry facilities shall be clean and maintained in good repair. (9) Lodging establishments shall in general be kept in a clean and sanitary condition and in good repair. Kitchen amenities in guestrooms with kitchens or kitchenettes shall be properly maintained and in good working order. (10) The lodging establishment shall keep, for a period of no less than ninety days, records of the cleaning frequency of rooms that are used for extended guests stays. The records shall include information regarding the last cleaning performed and any room damage or repairs. (11) No employee of a lodging establishment who is a carrier of or infected with a communicable disease (as specified by the Health Authority), or who is affected with a boil, an infected wound or an acute respiratory infection, shall work in a lodging establishment in any capacity in which there is a likelihood that the employee may transmit the disease to other persons. Employees who work with or handle single service items, such as clean laundry, ice or beverages or who perform tasks that would contaminate their hands shall thoroughly wash their hands and exposed areas of their arms before starting work, after smoking, eating or using the toilet. Employees shall keep their fingernails trimmed evenly and clean. Employees involved in guest services and housekeeping functions shall wear clean clothing, in good repair. When performing cleaning functions that could bring the employee into contact with human waste or bodily fluids, the employee shall be provided protective gloves for optional use. (12) Not more than ten percent of the lodging rooms in lodging establishment may be used for storage purposes. At least ninety percent of the lodging rooms in a lodging establishment shall be available for occupancy or occupied by a guest. (13) A lodging room may not be occupied by more persons than allowed by section 21.01 (fire code) or section 30.01 (building code) which shall be calculated by taking into account the space taken up by luggage and other personal belongings of an occupant that are not stored in a closet, dresser or other building feature or furniture provided by the operator of the lodging establishment.

( Ordinance 4594 , sec. 1, adopted 5/19/92 ; Ordinance 4931 , sec. 1, adopted 1/9/96 ; Ordinance 5094 , sec. 2, adopted 7/15/97 ; Ordinance 5895 , sec. 1, adopted 4/19/05 ; Ordinance 6126 , secs. 7–9, adopted 5/1/07 ; Ordinance 6327 , secs. 1, 2, adopted 7/7/09 ; Ordinance 6671 , secs. 3–5, adopted 1/21/14 ; Ordinance 7645 adopted 2/3/2026 )

Ask a question about Garland law

Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.