§ 4.83 — Nonresidential and Multifamily Building Materials and Design
Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Development Code § 4.83
Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/ef233af9-4c0b-4b84-adc2-daaf0d66bc71
§ 4.83: Nonresidential and Multifamily Building Materials and Design.
(A) Architectural Elements. (1) All nonresidential and multifamily buildings must incorporate design elements that create character or reflect regional architecture by including at least six of the following elements (for which photos and examples are provided below the list): (a) Awnings or canopies; (b) Display windows; (c) Divided light windows; (d) Transoms; (e) Shutters; (f) Alcoves/porticos; (g) Recessed entries; (h) Ornamental window headers/lintels; (i) Quoins; (j) Distinctive lighting features; (k) Planters or fountains; (l) Benches for outdoor seating; (m) Dormers; (n) Varied roof heights; (o) Ornamental facade trims; (p) Bay windows; and (q) Gable windows. [image] (B) Facade Articulation. (1) Horizontal building articulation (facade depth) and vertical building articulation (facade height) is required on all street-facing facades of all nonresidential and multifamily buildings in the manner and in conformity with the standards provided in Illustration 4-7. (2) Facade offsets must be shown, along with calculations verifying that the building elevations meet the above requirements, on a building Facade (elevation) Plan. The building Facade Plan must be submitted for review at the time of the initial development application along with the building elevations. (3) Canopies, arches, and covered colonnades count toward applicable facade depth or height articulation requirements. (4) Visual examples of acceptable facade articulation are provided in the photos which are provided below. (C) Parking Structures. (1) All above-grade parking structures must be designed to blend in with the architectural style of the main building(s), and must incorporate at least two of the following design elements: (a) Distinctive architectural elements such as cornices, piers, columns, friezes, quoins, mullions, fenestration, pilasters, rustication, or accentuating belt courses. Examples of such distinctive architectural elements may be found in Illustration 2-8 in Chapter 2 of this GDC; (b) Variation in wall planes such as wall openings, canopies, articulations, wall convexities, wall concavities, balconies, or awnings. Examples of such variation in wall planes may be found in Illustration 2-8 in Chapter 2 of this GDC; and (c) Change in materials. Such a change must involve a minimum of two separate, compatible materials, excluding glazing. Each area covered by the separate material must cover at least twenty percent of each facade’s surface area, excluding glazing. (d) Change in colors. Such a change must involve a minimum of two, compatible color changes, excluding glazing. Each area covered by the color change must cover at least twenty percent of each facade’s surface area, excluding glazing. (2) All above-grade parking structures must be designed with a distinguishable first floor, upper facades, and roofs. Parking garage first floors must be designed at human scale with pedestrian-scale elements such as awnings, canopies, window breaks, and door openings. (3) Above-grade parking garages may be designed using decorative metal elements such as ornate meshes, screens, and the like, but must not be allowed to have non-decorative steel guard cables that are visible to the public or to adjacent properties. (D) Windows. Highly reflective mirror glass may not be installed as an exterior building material on any building or structure unless the installation is done in such a manner as to ensure that the material will not reflect light upon any other real property (whether public or privately owned), building, or structure. However, in order to encourage energy efficiency, the use of tinted or inward facing mirrored glass is allowed and encouraged. Illustration 4-7 Horizontal and Vertical Building Articulation [image] [image] [image] Illustration 4-7 cont’d. Horizontal and Vertical Building Articulation (how to measure 30' increments) [image] Examples of Acceptable Facade Articulation [image] [image] (E) Canopies. All canopies that are intended to shelter vehicles or vehicular traffic such as a building’s porte cochere, a bank’s drive-through canopy, or a fuel station canopy, must have support columns constructed with the same type of masonry construction material used on the main building(s) facades, if any, or otherwise are in a manner architecturally compatible with the main building’s facade.
( Ordinance 6773 adopted 5/19/15 ; Ordinance 7079 , sec. 40, adopted 8/20/19 ; Ordinance 7107 , sec. 78, adopted 12/3/19 ; Ordinance 7404 adopted 2/21/2023 )
Ask a question about Garland law
Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
