§ 4.97 — Walkway Lighting
Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Development Code § 4.97
Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/d6e5fdd0-2e8e-4928-bd96-171b5233c05e
§ 4.97: Walkway Lighting.
Walkway lighting must comply with the following provisions: (A) Intensity. All outdoor pedestrian areas and uncovered walkways, separate from parking or buildings but essential to the nighttime operation of nonresidential uses within nonresidential districts, must be continually illuminated between sunset and sunrise. The level of intensity of illumination, measured at the walkway surface, is a minimum average of 0.8 footcandle. For pedestrian walkways located within one hundred feet of a residential district, and for all sidewalks on private property within a residential district (excluding public sidewalks along street rights-of-way), walkway lighting must be low “bollard”-style (not mounted on light poles over five feet tall) so that lighting occurs as a “groundwash” on the walkways and does not overspill into residential lots. (B) Mounting Height. The mounting height of luminaire fixtures within one hundred feet of a residential district may not exceed twelve feet above the ground.
( Ordinance 6773 adopted 5/19/15 )