For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 29-18 — Substandard buildings

Code of Ordinances, City of Grand Prairie, Texas (Supp. No. 117, Update 1: codified through Ordinance No. 1857-2026, adopted April 27, 2026) · Grand Prairie City Code § 29-18

Corpus is an independent public-information project, not the official City of Grand Prairie website. Stable reference: corpuslaw.us/code/d96bfcef-3f9b-4c32-82ae-c47c33e1c4c2

Sec. 29-18. - Substandard buildings.

Any building or portion thereof, including any dwelling unit, guest room or suites of rooms, or the premises on which the same is located, in which there exists any of the following listed conditions to an extent that endangers the life, limb, health, property, safety or welfare of the public or the occupant thereof shall be deemed and hereby is declared to be a substandard building: (1) Inadequate sanitation, which shall include, but not be limited to the following: a. Lack of or improper water closets, lavatory, bathtub or shower in a dwelling unit. b. Lack of or improper water closets, lavatories and bathtubs or showers per number of guests in a hotel. c. Lack of or improper kitchen sink. d. Lack of hot and cold running water to plumbing fixtures in a hotel. e. Lack of hot and cold running water to plumbing fixtures in a dwelling unit. f. Lack of adequate heating facilities. g. Lack of or improper operation of required ventilating equipment. h. Lack of minimum amounts of natural light and ventilation required by this article. i. Room and space dimensions less than required by article. j. Lack of required electrical lighting. k. Infestation of insects, vermin or rodents. l. General dilapidation or improper maintenance. m. Lack of connection to required sewage disposal system. n. Lack of adequate garbage and rubbish storage and removal facilities. (2) Structural hazards, which shall include, but not be limited to the following: a. Deteriorated or inadequate foundations. b. Defective or deteriorated flooring or floor supports. c. Flooring or floor supports of insufficient size to carry imposed loads with safety. d. Members of walls, partitions or other vertical supports that split, lean, list or buckle due to defective material or deterioration. e. Members of walls, partitions or other vertical supports that are of insufficient size to carry imposed loads with safety. f. Members of ceilings, roofs, ceiling and roof supports or other horizontal members which sag, split or buckle due to defective material or deterioration. g. Members of ceilings, roofs, ceiling and roof supports or other horizontal members that are of insufficient size to carry imposed loads with safety. h. Fireplaces or chimneys which list, bulge or settle due to defective material or deterioration. i. Fireplaces or chimneys which are of insufficient size or strength to carry imposed loads with safety. (3) Nuisance, which shall include, but not be limited to any nuisance as defined in this article or in this Code. (4) Hazardous wiring, which shall include all wiring except that which conformed with all applicable laws in effect at the time of installation and which has been maintained in good condition and is being used in a safe manner. (5) Hazardous plumbing, which shall include all plumbing except that which conformed with all applicable laws in effect at the time of installation and which has been maintained in good condition and which is free of cross connections and siphon age between fixtures. (6) Hazardous mechanical equipment, which shall include all mechanical equipment, including vents, except that which conformed with all applicable laws in effect at the time of installation and which has been maintained in good and safe condition. (7) Faulty weather protection, which shall include, but not be limited to the following: a. Deteriorated, crumbling or loose plaster. b. Deteriorated or ineffective waterproofing of exterior walls, roofs, foundations or floors, including broken windows or doors. c. Defective or lack of weather protection for exterior wall coverings, including lack of paint, or weathering due to lack of paint or other approved protective covering. d. Broken, rotted, split or buckled exterior wall coverings or roof covering. (8) Fire hazard, which shall include, but not be limited to, any building [or] portion thereof, device, apparatus, equipment, combustible waste, or vegetation which, in the opinion of the chief of the fire department or the chief's deputy, is in such a condition as to cause a fire or explosion arising from any cause. (9) Faulty materials of construction, which shall include all materials of construction except those which are specifically allowed or approved by this chapter and which have been adequately maintained in good and safe condition. (10) Hazardous or unsanitary premises, which shall include, but not be limited to, those premises on which an accumulation of weeds, vegetation, junk, dead organic matter, debris, garbage, offal, rat harborages, stagnant water, combustible materials and similar materials or conditions constitute fire, health or safety hazards. (11) Inadequate maintenance, which shall include, but not be limited to, any building or portion thereof which is determined to be an unsafe building in accordance with any applicable building code or article VI of this chapter. (12) Inadequate exits, which shall include, but not be limited to, all buildings or portions thereof not provided with adequate exit facilities as required by this Code, except those buildings or portions thereof whose exit facilities conformed with all applicable laws at the time of their construction and which have been adequately maintained and increased in relation to any increase in occupant load, alteration or addition, or any change in occupancy. When an unsafe condition exists through lack of or improper location of exits, additional exits may be required to be installed. (13) Inadequate fire protection or firefighting equipment, which shall include, but not be limited to, all buildings or portions thereof which are not provided with the fire-resistive construction or fire extinguishing systems or equipment required by this Code, except those buildings or portions thereof which conformed with all applicable laws at the time of their construction and whose fire-resistive integrity and fire extinguishing systems or equipment have been adequately maintained and improved in relation to any increase in occupant load, alteration or addition or any change in occupancy. (14) Improper occupancy, which shall include all buildings or portions thereof occupied for living, sleeping, cooking or eating purposes which were not designed or intended to be used for such occupancies. (15) Lack of storage space, which shall include all buildings or portions thereof not provided with the storage and storage space required by this article or which do not have the porch roof protection required hereunder. (16) Accessory structures. Buildings or accessory structures of any type of construction, including carports, shed, detached and/or attached garages, patios, porches and exterior attachments permitted by the applicable building code, and all roofs, exterior walls and all other structural components of the buildings must be free of: a. Peeling paint. If over fifty (50) per cent of the building has peeling paint, the entire building will be scraped and repainted. If less than fifty (50) per cent, then the affected areas will be scraped and repainted. b. Broken windows. All broken glass will be replaced or the opening secured in an acceptable manner with plywood or another acceptable material. c. Missing or deteriorated or rotted siding, panels, brick, etc., [which] will be repaired with comparable materials if damaged. d. Nonfunctioning garage doors. All garage doors will be maintained in a secured manner, fully capable of opening and closing, and, if damaged, must be repaired with comparable materials. e. Inadequate roofs. All roofs shall be maintained to be structurally sound and free of leaks. f. Faulty or hazardous electrical wiring. All electrical wiring, fixtures and outlets must meet the minimum requirements of the applicable building code as adopted by the city at the time of construction, and be maintained in a manner to remain free of any electrical hazards. g. Insufficient exterior attachments. All must be maintained in good repair and be properly anchored.

(Ord. No. 5059, § 1, 12-15-92; Ord. No. 5679, § 2, 10-15-96; Ord. No. 7746, § 1, 3-4-08)

Ask a question about Grand Prairie law

Corpus searches the Grand Prairie sections it holds and shows the ones that match, with their citations. Free, no sign-in.